Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
SYS.OK|MANUAL.DB● LIVE
HOMESERVICE MANUALSFORD2004FOCUS ZX5, 2.3 Z, STANDARDREPAIR AND DIAGNOSIS (SINGLE PAGE)ENGINE PERFORMANCESYSTEMENGINE CONTROLS - REFERENCE VALUES - ECONOLINE THROUGH EXPLORER/MOUNTAINEER - CNG, FLEX-FUEL & GASOLINEEXPLORER/MOUNTAINEER 4.0L SOHC
2004 Ford Focus ZX5, 2.3 Z, Standard
Explorer/Mountaineer 4.0L SOHC
2004 Ford Focus ZX5, 2.3 Z, StandardSECTION Explorer/Mountaineer 4.0L SOHC
SENSORS/INPUT - 4.0L SOHC EXPLORER/MOUNTAINEER
| Sensors/Inputs | PCM Pin/PID only | Measured/PID Values | Units Measured/PID | |||
|---|---|---|---|---|---|---|
| KOEO | Hot Idle | 30 MPH | 55 MPH | |||
| ACDS | B3 | .1 | .1 | .1 | .1 | DCV |
| APP1 | B5 | 4.0 | 4.0 | 3.4-4.0 | 2.9-4.0 | DCV |
| BPS | B7 | VBAT/OFF | .1/ON (E) | VBAT/OFF | VBAT/OFF | DCV/OFF-ON |
| BPP | B8 | .1/OFF | VBAT/ON (E) | .1/OFF | .1/OFF | DCV/OFF-ON |
| FTP V/FTP | B9 | 2.6/0 | 2.6/0 | 2.6/0 | 2.6/0 | DCV/IN-H2O |
| IAT | B16 | 1.7-3.5/120-50 (K) | 1.7-3.5/120-50 (K) | 1.7-3.5/120-50 (K) | 1.7-3.5/120-50 (K) | DCV/DEG |
| APP2 | B17 | 1.5 | 1.5 | 1.5-1.9 | 1.5-2.4 | DCV |
| FPM | B21 | .1 | 0-VBAT | 0-VBAT | 0-VBAT | DCV |
| 4WD MC SW | B22 | VBAT | VBAT | VBAT | VBAT | DCV |
| ILC | B24 | .7 | 9 | 9 | 9 | DCV |
| ACP V | B26 | VBAT | VBAT | VBAT | VBAT | DCV |
| TCS | B27 | .1/OFF | VBAT/ON (G) | .1/OFF | .1/OFF | DCV/OFF-ON |
| APP3 | B28 | .9 | .9 | .9-1.3 | .9-1.8 | DCV |
| 4WDSW RTN | B29 | 0 | 0 | 0 | 0 | DCV |
| MAF V | B32 | 0 | .7-.9 | 1.2-1.6 | 1.6-2.1 | DCV |
| PATSIN | B42 | VBAT | VBAT | VBAT | VBAT | DCV |
| FEPS | B44 | .1 | .1 | .1 | .1 | DCV |
| 4WD_PWR | B50 | VBAT | VBAT | VBAT | VBAT | DCV |
| OSS | T3 | 0 | 0 | 460-530/1250-1290 | 885-1000/2100-2400 | Hz/RPM |
| HCDS | T4 | 0 | 0 | 700 | 1180 | Hz |
| 4WD_POS1 | T7 | VBAT | VBAT | VBAT | VBAT | DCV |
| 4WD_POS2 | T8 | VBAT | VBAT | VBAT | VBAT | DCV |
| TSS | T15 | 0 | 320-360/630-670 | 500-713/1100-1300 | 845-985/1700-1800 | Hz/RPM |
| TR 1 | T16 | 0 | 0 | VBAT | VBAT | DCV |
| TR 2 | T17 | 0 | 0 | VBAT | VBAT | DCV |
| 4WD_POS3 | T19 | VBAT | VBAT | VBAT | VBAT | DCV |
| 4WD_POS4 | T20 | VBAT | VBAT | VBAT | VBAT | DCV |
| O2S12 | T24 | .1 | (D) | (D) | (D) | DCV |
| O2S22 | T25 | .1 | (D) | (D) | (D) | DCV |
| TR3 V/TR3 | T27 | 0/PARK | 0/PARK | 1.7/OD | 1.7/OD | DCV/MODE |
| TR 4 | T28 | 0 | 0 | VBAT | VBAT | DCV |
| TFT | T29 | .5-2/210-110 | .5-2/210-110 | .5-2/210-110 | .5-2/210-110 | DCV/DEG |
| TP1 | E19 | 4.1 | 4.4 | 4.1 | 4.0 | DCV |
| ECT | E21 | .4-1/200-160 | .4-1/200-160 | .4-1/200-160 | .4-1/200-160 | DCV/DEG |
| CID | E25 | 0 | 5-6 | 11-12 | 14-16 | Hz |
| TP2 | E29 | 1.2 | .8 | 1.1 | 1.4 | DCV |
| O2S11 | E30 | 0 | switching (C) | switching (C) | switching (C) | DCV |
| O2S21 | E31 | 0 | switching (C) | switching (C) | switching (C) | DCV |
| KS1 | E32 | 0 | 0 | 0 | 0 | DCV |
| CKP | E34 | 0 | 380-410 | 800-860 | 980-1030 | Hz |
| FRT | E36 | .5-3/210-110 | .5-3/210-110 | .5-3/210-110 | .5-3/210-110 | DCV/DEG |
| FRP V/FRP | E37 | 3.4/50 | 2.8/40 | 2.8/40 | 2.8/40 | DCV/PSI |
| DPFEGR | E44 | .25-1.30 | .25-1.30 | .25-4.65 | .25-4.65 | DCV |
| ACCS | PID | OFF | ON (A) | OFF | OFF | OFF-ON |
| FLI (H) | PID | 50 | 50 | 50 | 50 | % |
| GEAR | PID | 1 | 1 | 4 | 5 | GEAR |
| LOAD | PID | (L) | 17-28 | 19-26 | 30-40 | % |
| RPM | PID | 0 | 750 | 1300-1350 | 1780 | RPM |
| VSS | PID | 0 | 0 | 30 | 55 | MPH |
ACTUATORS/OUTPUTS - 4.0L SOHC EXPLORER/MOUNTAINEER
| Actuators/Outputs | PCM Pin/PID only | Measured/PID Values | Units Measured/PID | |||
|---|---|---|---|---|---|---|
| KOEO | Hot Idle | 30 MPH | 55 MPH | |||
| PATSTRT | B2 | .1 | .5 | .5 | .5 | DCV |
| FP | B12 | 8.4 | 2.5 | 2.8 | 2.8 | DCV |
| EVAPCV | B13 | VBAT/0 | VBAT/0 | VBAT/0 (S) | VBAT/0 (S) | DCV/% |
| WAC (ACCR) | B25 | VBAT/OFF | .1/ON (A) | VBAT/OFF | VBAT/OFF | DCV/OFF-ON |
| PATSOUT | B31 | VBAT | VBAT | VBAT | VBAT | DCV |
| EVMV | B34 | 0 | 0 | 500-900 (F) | 500-900 (F) | mA |
| PATSIL | B37 | 11.0 | 13.0 | 13.0 | 13.0 | DCV |
| EPC | T11 | 6.0 | 8.0 | 10.0 | 10.0 | DCV |
| EPC2 | T23 | 8.0 | 10.0 | 10.0 | 10.0 | DCV |
| EPC3 | T34 | 6.0 | 8.0 | VBAT | VBAT | DCV |
| SS1 | T42 | .1/ON | .1/ON | VBAT/OFF | VBAT/OFF | DCV/OFF-ON |
| SS2 | T43 | VBAT/OFF | VBAT/OFF | VBAT/OFF | VBAT/OFF | DCV/OFF-ON |
| SS3 | T44 | VBAT/OFF | VBAT/OFF | VBAT/OFF | .1/ON | DCV/OFF-ON |
| SS4 | T45 | .1/ON | .1/ON | .1/ON | .1/ON | DCV/OFF-ON |
| TCC | T46 | VBAT/0 | VBAT/0 | VBAT/0 | .2/100 | DCV/% |
| HTR12 | T47 | .2/ON (P) | .2/ON | .2/ON | .2/ON | DCV/OFF-ON |
| HTR22 | T48 | .2/ON (P) | .2/ON | .2/ON | .2/ON | DCV/OFF-ON |
| 4WD_CLUTCH | T49 | .5 | .2 | .2 | .2 | DCV |
| CDA (CYL 1&5) | E1 | VBAT | VBAT | VBAT | VBAT | DCV |
| INJ1 | E2 | 0 | 2.9-3.3 | 3.1-5.1 | 6-7 | mS |
| INJ2 | E3 | 0 | 2.9-3.3 | 3.1-5.1 | 6-7 | mS |
| INJ3 | E4 | 0 | 2.9-3.3 | 3.1-5.1 | 6-7 | mS |
| INJ4 | E5 | 0 | 2.9-3.3 | 3.1-5.1 | 6-7 | mS |
| EGRVR | E6 | VBAT/0 | VBAT/0 | (V) | (V) | DCV/% |
| INJ5 | E8 | 0 | 2.9-3.3 | 3.1-5.1 | 6-7 | mS |
| INJ6 | E9 | 0 | 2.9-3.3 | 3.1-5.1 | 6-7 | mS |
| CDB (CYL 3&4) | E12 | VBAT | VBAT | VBAT | VBAT | DCV |
| CDC (CYL 2&6) | E24 | VBAT | VBAT | VBAT | VBAT | DCV |
| TACMP | E47 | 3.8 | VBAT | VBAT | VBAT | DCV |
| TACMN | E48 | 3.8 | VBAT | VBAT | VBAT | DCV |
| HTR11 | E49 | .1/ON (P) | .1/ON | .1/ON | .1/ON | DCV/OFF-ON |
| HTR21 | E50 | .1/ON (P) | .1/ON | .1/ON | .1/ON | DCV/OFF-ON |
| LONGFT1 | PID | (-)20-(+)20 | (-)20-(+)20 | (-)20-(+)20 | (-)20-(+)20 | % |
| LONGFT2 | PID | (-)20-(+)20 | (-)20-(+)20 | (-)20-(+)20 | (-)20-(+)20 | % |
| MIL | PID | OFF | OFF | OFF | OFF | OFF-ON |
| SHRTFT1 | PID | 0 | (-)10-(+)10 | (-)10-(+)10 | (-)10-(+)10 | % |
| SHRTFT2 | PID | 0 | (-)10-(+)10 | (-)10-(+)10 | (-)10-(+)10 | % |
| SPARKADV | PID | 0 | 20-25 | 30-35 | 30-35 | DEG |
| TCIL | PID | OFF | OFF | OFF | OFF | OFF-ON |
OTHERS - 4.0L SOHC EXPLORER/MOUNTAINEER
| Other | PCM Pin/PID only | Measured/PID Values | Units Measured/PID | |||
|---|---|---|---|---|---|---|
| KOEO | Hot Idle | 30 MPH | 55 MPH | |||
| KAPWR | B45 | VBAT | VBAT | VBAT | VBAT | DCV |
| VPWR B35, | 36 | VBAT | VBAT | VBAT | VBAT | DCV |
| VREF B40, | E40 | 5 | 5 | 5 | 5 | DCV |
| ETCVREF B4, | E18 | 5 | 5 | 5 | 5 | DCV |
GENERIC OBD II PID VALUES - 4.0L SOHC EXPLORER/MOUNTAINEER
|
NOTE:
All generic OBD II readings under no load (PARK or NEUTRAL).
|
|||
|---|---|---|---|
| PID | Hot Idle | 2500 RPM | Units |
| LONGFT1 | (-)20-(+)20 | (-)20-(+)20 | % |
| LONGFT2 | (-)20-(+)20 | (-)20-(+)20 | % |
| LOAD | 17-28 | 17-24 | % |
| MAF | 4.8-7 | 14-17 | G/S |
| SHRTFT1 | (-)10-(+)10 | (-)10-(+)10 | % |
| SHRTFT2 | (-)10-(+)10 | (-)10-(+)10 | % |
| SHRTFT11 | (-)10-(+)10 | (-)10-(+)10 | % |
| SHRTFT12 | 95-100 | 95-100 | % |
| SHRTFT21 | (-)10-(+)10 | (-)10-(+)10 | % |
| SHRTFT22 | 95-100 | 95-100 | % |
| SPARKADV | 20-25 | 40 | DEG |
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.