P0446: EVAP Control System Canister Vent Solenoid Circuit Malfunction

2004 Ford Focus ZX3, 2.3 Z, StandardSECTION P0446: EVAP Control System Canister Vent Solenoid Circuit Malfunction
P0446 - EVAP CONTROL SYSTEM CANISTER VENT SOLENOID CIRCUIT MALFUNCTION

Description:  Monitors the canister vent (CV) solenoid circuit for an electrical failure. The test fails when the signal moves outside the minimum or maximum allowable calibrated parameters for a specified canister vent duty cycle by PCM command.
Possible Causes: 
  • VPWR circuit open.
  • CV solenoid circuit shorted to PWR GND or CHASSIS GND.
  • Damaged CV solenoid.
  • CV solenoid circuit open.
  • CV solenoid circuit shorted to VPWR.
  • Damaged PCM.
Diagnostic Aids:  To verify normal functioning, monitor the EVAP canister vent solenoid signal PID EVAPCV and the signal voltage (PCM control side). With the valve open, EVAPCV indicates 0% duty cycle and a voltage approximately equal to battery voltage. When the valve is commanded fully closed, EVAPCV indicates 100% duty cycle, and a minimum voltage drop of 4 volts is normal. Output test mode may be used to switch output on/off to verify function.
Application  Key On Engine Off  Key On Engine Running  Continuous Memory 
All GO to PINPOINT TEST HX: EVAPORATIVE EMISSION (EVAP) MONITOR AND SYSTEM Step 34.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.