Master Window Regulator Control Switch

1999 Ford Windstar Base, Van Cargo, 3.8 4SECTION Master Window Regulator Control Switch

Disconnect master window regulator control switch. Check continuity between specified master window regulator control switch terminals with switch in appropriate position. See MASTER WINDOW REGULATOR CONTROL SWITCHΒ  table. See Fig 1 and Fig 2 . If continuity is not as specified, replace master window regulator control switch.

MASTER WINDOW REGULATOR CONTROL SWITCH

Connector (Terminals No.) Switch Position Specification
One-Touch Down Circuit
C501 (6 & 2) Down 480 ohms
Power/Ground Checks Before Other Tests
C501 (6 & 7) Both Front Switches (All Positions) No
C501 (7 & All Others, Except 6 & 2) Both Front Switches (At Rest) Yes
Left Front Window Circuit
C501 (6 & 3) Up Yes
C501 (6 & 1) Down Yes
Right Front Window Switch
C501 (6 & 4) Up Yes
C501 (6 & 5) Down Yes
Left Flip Window Switch
C514 (1 & 5) Up Yes
C514 (1 & 4) Down Yes
Right Flip Window Switch
C514 (1 & 7) Up Yes
C514 (1 & 6) Down Yes
Fig 1: Identifying Master Window Regulator Control Connector C501 Terminals
G98A01448Courtesy of FORD MOTOR CO.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.