Typical Diagnostic Reference Values

1999 Ford Mustang GT, 2D Convertible, StandardSECTION Typical Diagnostic Reference Values
WARNING: This page does not describe the selected car, but rather 32 other vehicles, including the 2008 Mercury Sable, 2008 Mercury Mountaineer, 2008 Mercury Milan, 2008 Mercury Mariner, and 2008 Mercury Grand Marquis. However, it is still accessible from the selected car via links, so may be relevant.
Sensors/Inputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
BOO1 B13 OFF ON (E) OFF OFF ON/OFF
APP1 B28 0.77/15.29 0.77/15.29 1.38/25.49 1.45/28.24 DCV/%
APP2 B29 0.38/7.45 0.38/7.45 0.69/13.73 0.73/14.51 DCV/%
ACP_PRESS B31 1.56/66.55 1.69/74.53 1.45/59.30 1.39/55.69 DCV/PSI
FPM B32 0 100 100 100 %
MAF B40 0 0.6 1.83 1.87 DCV
BOO2 B46 OFF ON (E) OFF OFF ON/OFF
IAT B47 1.78/120.2 (K) 1.99/111.2 (K) 2.53/93.2 (K) 2.66/87.8 (K) DCV/DEG F
FTP B65 2.6/0 2.6/0 2.6/0 2.6/0 DCV/PSI
O2S11 E11 (L) switching (C) switching (C) switching (C) DCV
CHT E15 3.2/224.6 3.56/204.8 0.67/186.8 0.67/186.8 DCV/DEG F
IMRC1M (PZEV) E25 0.1 0.1 4.98 4.98 DCV
MAP E40 4.02/14.35 (W) 1.15/4.06(W) 2.42/8.70 (W) 3.15/11.31 (W) DCV/PSI
TP1 E44 4.10 4.33 3.90 4.06 DCV
TP2 E45 1.19 0.72 1.60 1.27 DCV
HTRCM11 E52 1.58 1.58 1.65 1.65 AMPS
O2S13 (PZEV) T7 0.1 (D) (D) (D) DCV
O2S12 T16 (L) (D) (D) (D) DCV
HTRCM12 T18 676 676 634 634 mA
TFT (A/T) T19 118 (K) 117 (K) 147 (K) 144 (K) DEG F
TFTV (A/T) T19 1.9 (K) 1.9 (K) 1.3 (K) 1.4 (K) DCV
PSP T29 OFF OFF OFF OFF ON/OFF
TCC (A/T) T30 0 0 0 99.61 %
TSS_SRC (A/T) T37 0 731 1513 1844 RPM
APP PID 0 0 19 21 %
APP_
MAXDIFF
PID 0 0 0 -0.06 DEG
BARO PID 14.5/29.53 14.5/29.53 14.5/29.53 14.5/29.53 PSI/IN HG
B+ PID VBAT VBAT VBAT VBAT DCV
CPP/PNP PID NEUTRAL NEUTRAL DRIVE DRIVE MODE
DECHOKE PID YES NO NO NO YES/NO
ETC_ACT PID 7.73 1.48 7.79 8.25 DEG
ETC_DSD PID 7.60 1.45 7.71 8.12 DEG
ETC_TRIM PID 0 0 0.01 0.02 DEG
GENMON PID 0 54.9 18.96 22.1 %
LOAD PID 0 (L) 27 55.29 74.9 %
MISFIRE PID NO NO NO NO YES/NO
O2BANK1 PID VARIES VARIES VARIES VARIES RICH/LEAN
RPM PID 0 702 2527 1887 RPM
TP_MAXDIFF PID -4 -8 -8 -8 DEG
TR (A/T) PID PARK PARK OVERDRIVE OVERDRIVE MODE
VSS PID 0 0 30 55 MPH
Actuators/Outputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
FP B19 0/OFF 100/ON 100/ON 100/ON %/ON-OFF
EVAPCV B20 0/OFF 0/OFF 0/OFF 0/OFF %/ON-OFF
EVMV B55 0/OFF 0/OFF 500-900
(F)/VARYING
500-900
(F)/VARYING
mA/OFF-
VARYING
IMRC (PZEV) E22 ON ON OFF OFF ON/OFF
HTR11 E52 OFF (O) ON ON ON ON/OFF
SSA (SS1) (A/T) T11 OFF ON OFF OFF ON/OFF
HTR12 T18 OFF (O) ON ON ON ON/OFF
SSB (SS2) (A/T) T23 0/OFF 0/OFF 0/OFF 100/ON %/ON-OFF
HTR13 (PZEV) T25 OFF (O) ON ON ON ON/OFF
EGRPCT PID 0 0.78 43.14 49.02 %
EGR_STEP PID 0 1 23 26 0-52
EVAP020C PID NO NO NO NO YES/NO
EVAPSOAK PID YES YES YES YES YES/NO
FUELSYS1 PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN/
CLOSED LOOP
GENCMD PID 0 0 (Q) 0 (Q) 0 (Q) %
HFC PID OFF ON (B) OFF OFF ON/OFF
LFC PID OFF ON (B) OFF OFF ON/OFF
LONGFT1 PID (L) (-)20-(+)20 (-)20-(+)20 (-)20-(+)20 %
LOOP_
CONTRL
PID OPEN OPEN CLOSED CLOSED OPEN/
CLOSED
PATSENABL PID ENABLED ENABLED ENABLED ENABLED ENABLED/
DISABLED
SHRTFT1 PID (L) (-)10-(+)10 (-)10-(+)10 (-)10-(+)10 %
SPARKADV PID 10 9.75 39.75 23.75 DEG
Other PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VREF B52, E63, T70 5 5 5 5 DCV
VPWR B67/68 VBAT VBAT VBAT VBAT DCV
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.