Pcm Controlled Charging System: Description

1999 Ford Mustang GT, 2D Convertible, StandardSECTION Description
WARNING: This page does not describe the selected car, but rather 32 other vehicles, including the 2002 Mercury Sable, 2002 Mercury Mountaineer, 2002 Mercury Grand Marquis, 2002 Mercury Cougar, and 2002 Lincoln Town Car. However, it is still accessible from the selected car via links, so may be relevant.

PCM controlled charging system provides many additional benefits over integral generator regulator system. First benefit is improved battery life. In an integral generator regulator system, regulator set point is established by a temperature sensor in the regulator which estimates battery temperature. With PCM controlled generator, regulator voltage set points are determined by PCM and communicated to regulator via generator communication line. PCM uses a calibratable algorithm to estimate battery temperature. Improving battery temperature will reduce battery damage caused by over and undercharging.

Second benefit is improved engine performance. Whenever PCM senses a Wide Open Throttle (WOT), PCM will momentarily lower regulator voltage set point. This reduces torque load of the generator on engine and improves acceleration. PCM has a calibratable time limit on this reduced voltage feature. This prevents the generator output from being cut back for an extended WOT period, which could cause battery discharge.

Third benefit is improved idle stability. In response to PCM generator communication signal, regulator uses a generator monitor signal to provide feedback to PCM. Generator monitor signal provides PCM with charging system information. If the charging system receives a transient electrical load which would normally affect idle stability, the PCM is notified. Because PCM can anticipate additional loads, actions can be taken to minimize idle sag. PCM can choose to either reduce regulator set point or increase engine idle speed.

Fourth benefit is reduced cranking efforts. PCM can reduce mechanical load on starter by initially commanding a low voltage set point. This may improve start times.

If PCM detects a charging system error, charge indicator will illuminate. Charge indicator will illuminate if PCM fails to see a signal on generator monitor line for a time period greater than 500 milliseconds. This command will also be used to indicate over-voltage conditions detected by generator.

Each time ignition switch is turned to RUN position, cluster will perform a bulb check by illuminating charge indicator. PCM will send a low voltage command if charging system is functioning properly. This message should be sent 250-450 milliseconds after ignition switch is turned to RUN position. If a low voltage command is not received by cluster, cluster will continue to illuminate charge indicator indefinitely.

RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.