Load Test

1997 Ford Ranger Base, 2D Pickup, 2.3 A, AutomaticSECTION Load Test
  1. Ensure drive belt is in good condition and properly tightened. Connect charging system load tester in accordance with manufacturer's instructions. Start and run engine at 2000 RPM and apply load until generator output amperage levels off.
  2. Record maximum generator amperage output. See GENERATOR OUTPUT SPECIFICATIONS TABLEΒ  for output values. If generator output is within 20 percent of rated output amperage and voltage remains 12.5-14.5 volts, generator output is okay. If generator does not produce rated output, proceed with appropriate testing.
GENERATOR OUTPUT SPECIFICATIONS

Application Amps Rating
Standard 95
Optional 130