1994 Ford Probe Base, AutomaticFACTORY OEM SERVICE PROCEDURE

Motor Resistance Check

Turn ignition off. Disconnect hydraulic actuator assembly 2-pin connector from motor. Set DVOM on 200-ohm scale. Measure resistance between terminals on motor connector. If resistance is less than one ohm, go to PINPOINT TEST MMR-6Β  . If resistance is more than one ohm, replace hydraulic actuator assembly.