Set Condition

2023 Dodge and Ram Durango SXT Plus, AWDSECTION Set Condition
  • Voltage on one of the Mode Door 2 Driver circuits is above 4.92 volts for more than 50 seconds.
NOTE:

Mode Door 2 normal operating position signal voltages:

MODE DOOR 2 - POSITION VS SIGNAL VOLTAGE

Door Position Minimum Position Signal Voltage Nominal Operating Position Signal Voltage Maximum Position Signal Voltage
Panel (0%)  3.48v 4.67v 5.00v
Bi-Level (26%)    3.75v  
Purge (45%)    2.84v  
Floor (60%)    2.25v  
Mix (74%)    1.63v  
Defrost (100%)  0.10v 0.60v 1.97v
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.