Diagnostic Test
2023 Dodge and Ram Durango GT Premium, RWDSECTION Diagnostic Test
CHECK FOR ACTIVE DTCS
- With the scan tool, record and erase the DTCs.
- Cycle the ignition switch from On to Off.
- Wait 30 seconds.
- Cycle the ignition on.
- With the scan tool, read the Active DTCs.
Does the scan tool display; B224E-96-POWER LIFTGATE MODULE INTERNAL - COMPONENT INTERNAL FAILURE?
No
- Operate the power liftgate open and closed several times. With the scan tool, read the DTCs. If this code appears, replace the Power Liftgate Module in accordance with the Service Information. Refer to MODULE, POWER LIFTGATE (PLGM), REMOVAL .
- Perform the BODY VERIFICATION TEST. Refer to BODY VERIFICATION TEST .
Yes
- Replace the Power Liftgate Module in accordance with the Service Information. Refer to MODULE, POWER LIFTGATE (PLGM), REMOVAL .
- Perform the BODY VERIFICATION TEST. Refer to BODY VERIFICATION TEST .
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.