1994 Chrysler LHSFACTORY OEM SERVICE PROCEDURE

Bleeding Hydraulic Control Unit

WARNING: Ensure manual or pressure bleeding procedure is performed before bleeding Hydraulic Control Unit (HCU).
  1. Bleed base brake system using standard manual or pressure bleeding procedures. See MANUAL BLEEDING or PRESSURE BLEEDING. Connect DRB to Blue 6-pin Chrysler Collision Detection (CCD) data link connector, located under lower dash panel, right of steering column. See Fig 1.
  2. Using DRB, select TEVES ABS MENU. Select ADJUSTMENTS. Ensure parking brake is set. Select BLEED BRAKES. DRB will display following in sequence: BLEED BRAKES ACTUATING MOTOR PUMP, BLEED BRAKES ACTUATING ALL OUTLET VALVES & MOTOR PUMP, BLEED BRAKES ACTUATING MOTOR PUMP, and BLEED BRAKES COMPLETE. After BLEED BRAKES COMPLETE is displayed, disconnect DRB. Repeat standard bleeding procedure.
Fig 1: Locating CCD Data Link Connector
G93G40770Courtesy of CHRYSLER CORP.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.