Dr9 - Code 42 & ATM Test Results "NNN" (ASD Relay To Logic Module CKT)
Turn ignition off. Disconnect logic module Blue connector. Connect voltmeter to Blue connector cavity No. 6 and ground. Turn ignition switch to "RUN" position. Press ATM button on diagnostic readout box (DRB). Voltmeter reading should be within one volt of battery voltage. If voltage reading is okay, replace logic module. If voltage reading is not okay, repair wire to cavity No. 6 for an open circuit to relay.