Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
SYS.OK|MANUAL.DBβ LIVE
HOMESERVICE MANUALSCHEVROLET2006SUBURBAN K2500, 6.0 UREPAIR AND DIAGNOSISEXTERNAL PAGESDIFFERENT CARSECTION 1311 (HYBRID ENERGY STORAGE SYSTEM)DIAGNOSTIC INFORMATION AND PROCEDURESDTC P0A81CIRCUIT/SYSTEM TESTING
2006 Chevrolet Suburban K2500, 6.0 U
Circuit/System Testing
2006 Chevrolet Suburban K2500, 6.0 USECTION Circuit/System Testing
WARNING: This page is about a different car, the 2008 GMC Yukon and 2008 Chevrolet Tahoe. However, it is still accessible from the selected car via links, so may be relevant.
- Identify how to disable high voltage.
- Identify how to test for the presence of high voltage.
- Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed.
- Ignition OFF, disable the high voltage at the drive motor generator battery. Refer to High Voltage DisablingΒ .
- Remove the drive motor generator battery case upper cover, front cover, and right side cover. Refer to Drive Motor Battery Case Upper Cover, Front Cover, and Right Side Cover ReplacementΒ .
- Ignition OFF, connect the 12 volt battery.
- Disconnect the harness connector at the battery vent fan motor.
- Connect a test lamp between the ignition circuit terminal 2 and ground.
- Ignition ON, command the battery pack vent fan speed to 60 percent. The test lamp should illuminate after a 5-7 second delay.
- If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance.
- Verify a test lamp illuminates between B+ and the ground circuit terminal 3.
- If the test lamp does not illuminate, test the ground circuit for an open/high resistance.
- Ignition OFF, connect the harness connector at the battery vent fan motor.
- Disconnect X2 harness connector at the BECM.
- Verify a test lamp illuminates between the vent fan relay control circuit terminal 7 and ground.
- If the test lamp does not illuminate, test the control circuit for an open/high resistance. If the circuit tests normal, replace the generator battery vent fan relay.
- Connect a 3A fused jumper wire between the vent fan motor relay control circuit terminal 7 and ground.
- Ignition ON, test for 4.8-5.2 volts between the signal circuit terminal 2 and ground.
- If the voltage is not within the specified range, test the signal circuit for a short to voltage, short to ground, or an open/high resistance. If the circuit tests normal, replace the generator battery vent fan.
- If all circuits test normal, replace the drive motor generator battery control module.
WARNING:
Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.
The High Voltage Disabling procedure will perform the following tasks:
Failure to follow the procedures exactly as written may result in serious injury or death.
The High Voltage Disabling procedure will perform the following tasks:
Failure to follow the procedures exactly as written may result in serious injury or death.
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.