Ignition Off/Run/Crank
| Circuit | Normal Range | Short to Ground | Open | Short to Voltage |
|---|---|---|---|---|
| Operating Conditions: Ignition Switch in OFF, w/key out or ACC | ||||
| Off/Run/Crank Voltage | Key Out/ACC | Key Out/ACC | Key Out/ACC | Key In-Off |
| Operating Conditions: Ignition Switch in OFF, w/key in | ||||
| Off/Run/Crank Voltage | Key In-Off | Key Out/ACC | Key Out/ACC | Key In-Off |
| Operating Conditions: Ignition Switch in RUN | ||||
| Off/Run/Crank Voltage | Run | Key Out/ACC | Key Out/ACC | Key In-Off |
| Operating Conditions: Ignition Switch in START | ||||
| Off/Run/Crank Voltage | Crank | Key Out/ACC | Key Out/ACC | Key In-Off |
Off/Run/Crank Signal
| Circuit | Normal Range | Short to Ground | Open | Short to Voltage |
|---|---|---|---|---|
| Operating Conditions: Ignition Switch in OFF, w/key out or ACC | ||||
| Off/Run/Crank Voltage | 0 | 0 | 0 | 51 |
| Operating Conditions: Ignition Switch in OFF, w/key in | ||||
| Off/Run/Crank Voltage | 51 | 0 | 0 | 51 |
| Operating Conditions: Ignition Switch in RUN | ||||
| Off/Run/Crank Voltage | 3.5-4.0 | 0 | 0 | 51 |
| Operating Conditions: Ignition Switch in START | ||||
| Off/Run/Crank Voltage | 1-2 | 0 | 0 | 51 |
| 1 The correct value should be B+, but the parameter was scaled to maximum 5 volts, to increase reading accuracy in the lower range. | ||||
Key In Status
| Circuit | Normal Range | Short to Ground | Open | Short to Voltage |
|---|---|---|---|---|
| Operating Conditions: Key in ignition switch | ||||
| Off/Run/Crank Voltage | Key In | Key Out | Key Out | Key In |
| Operating Conditions: Key out of ignition switch | ||||
| Off/Run/Crank Voltage | Key Out | Key Out | Key Out | Key In |
Off/Run/Crank Reference
| Circuit | Normal Range | Short to Ground | Open | Short to Voltage |
|---|---|---|---|---|
| Ignition Key Resistor Signal | 5 | 0 | 5 | 51 |
| 1 The correct value should be B+, but the parameter was scaled to maximum 5 volts, to increase reading accuracy in the lower range. | ||||
Ignition Run/Crank
| Circuit | Normal Range | Short to Ground | Open | Short to Voltage |
|---|---|---|---|---|
| Operating Conditions: Ignition Switch in RUN or START | ||||
| Ignition 1 Voltage | Active | Inactive | Inactive | Active |
| Operating Conditions: Ignition Switch in OFF or ACC | ||||
| Ignition 1 Voltage | Inactive | Inactive | Inactive | Active |
Ignition Accessory/Run
| Circuit | Normal Range | Short to Ground | Open | Short to Voltage |
|---|---|---|---|---|
| Operating Conditions: Ignition Switch in ACC or RUN | ||||
| Accessory Voltage | Active | Inactive | Inactive | Active |
| Operating Conditions: Ignition Switch in OFF or START | ||||
| Accessory Voltage | Inactive | Inactive | Inactive | Active |
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.