Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Scan Tool Data List
The Engine Scan Tool Data List contains all engine related parameters that are available on the scan tool. The list is arranged in alphabetical order. A given parameter may appear in any one of the data lists, and in some cases may appear more than once, or in more than one data list in order to group certain related parameters together.
Use the Engine Scan Tool Data List only after the following is determined:
- The Diagnostic System Check-Engine Controls is completed.
- No diagnostic trouble codes (DTCs)
- On-board diagnostics are functioning properly.
Scan tool values from a properly running engine may be used for comparison with the engine you are diagnosing. The Engine Scan Tool Data List represents values that would be seen on a normal running engine.
Only the parameters listed below are referenced in this service manual for use in diagnosis. If all values are within the typical range described below, refer to Symptoms - Engine Controls for diagnosis.
The column labeled Data List indicates where a parameter can be located on the scan tool. Refer to the scan tool operating manual for the exact locations of the data lists. The following is a description of each term listed:
- All
-
The Parameter is in all of the data lists indicated below.
- Eng 1
-
Engine Data 1 List
- Eng 2
-
Engine Data 2 List
- EGR
-
EGR Data List
- FT
-
Fuel Trim Data List
- MF
-
Misfire Data List
- EE
-
Enhanced EVAP Data List
- FF/FR
-
Freeze Frame/Failure Records
| Engine Idling/Radiator Hose Hot/Closed Throttle/Park or Neutral/Closed Loop/Accessories Off | |||
|---|---|---|---|
| Scan Tool Parameter | Data List | Parameter Range/Units | Typical Data Values |
| 4WD Signal | Eng 2 | Enabled/Disabled | Disabled |
| 4WD Low Signal | Eng 2 | Enabled/Disabled | Disabled |
| A/C Clutch Feedback Signal | Eng 2 | ON/OFF | OFF |
| A/C Compressor Cycling Switch | Eng 2 | Low/High Pressure | Low Pressure |
| A/C High Pressure Recirculation | Eng 2 | Normal/Low | Normal |
| A/C Relay Command | Eng 1, 2, EGR, MF | On/Off | Off |
| A/C Request Signal | Eng 2 | Yes/No | No |
| Air Fuel Ratio | FF, FR | Ratio | 14.7:1 |
| AIR Pump Relay Command (w/NC1) |
Eng 1, FT | On/Off | Off |
| BARO | Eng 1, EE, EGR, FT, FF, FR | kPa/volts | 65-104 kPa/3.5-4.9 Volts Varies w/Altitude |
| Clutch Pedal Switch (Manual Transmission only) |
Eng 1, 2, EGR | Depressed/Released | Released |
| CMP Retard | Eng 1 | Degrees | 1° |
| CMP Sensor - High to Low | Eng 2 | Counts | Varies |
| CMP Sensor - Low To High | Eng 2 | Counts | Varies |
| Cruise Control Active | Eng 1 | Yes/No | No |
| Cruise Inhibit Signal Command | Eng 1 | ON/OFF | ON |
| Current Gear | Eng 1, 2, EGR, FF, FR, FT | 0-4 | 1 |
| Cycles of Misfire Data | MF | 0-100 Counts | Varies |
| Desired EGR Position | Eng 1, EGR, FF, FR, MF | 0-100% | 0% |
| Desired EGR Position | EGR | 0-5 volts | Less than 1.3 volts |
| Desired IAC Airflow | Eng 1 | 0-64 g/s | Varies |
| Desired IAC Position | Eng 1 | Counts | Varies |
| Desired Idle Speed | Eng 1, 2, EE, FF, FR | RPM | PCM Controlled |
| DTC Set This Ignition | Eng 1, 2, EE, FT | Yes/No | No |
| ECT Sensor | Eng 1, 2, EE, EGR, FT, MF, FF, FR | -39 to +140°C (-38 to +284°F) | 88 to 105°C (190 to 221°F) Depends on ambient temperature |
| EGR Learned Minimum Position | EGR | 0-5.0 volts | Less than 1.3 volts |
| EGR Position Sensor | Eng 1, EGR, FF, FR, MF | 0-5.0 volts | Less than 1.3 volts |
| EGR Position Sensor | Eng 1, EGR, MF | 0-100 % | 0 % |
| Engine Load | All | 0-100% | 1-4% @ Idle 7-9% @ 2500 RPM |
| Engine Oil Life Remaining | Eng 2 | 0-100% | Varies |
| Engine Run Time | All | Hrs, Min, Sec | Varies |
| Engine Speed | All | 0-10,000 RPM | 500-700 RPM |
| EVAP Purge Solenoid Command | Eng 1, EE, FT | 0-100% | 10-25% |
| EVAP Vent Solenoid Command | Eng 1, EE, FT | Not Venting/Venting | Venting |
| EVAP Test Abort Reason | EE | Aborted/Not Aborted | Not Aborted |
| EVAP Test Result | EE | Test Result | Varies |
| EVAP Test State | EE | Test State | Varies |
| Fail Counter | FF, FR | Counts | Varies |
| Fuel Level Sensor | EE | 0-5 volts | 0.7-2.5 volts |
| Fuel Tank Level Remaining | EE, FT | Gallon/Liter | Varies |
| Fuel Tank Level Remaining | EE, FT | 0-100% | Varies |
| Fuel Tank Pressure Sensor | Eng 1, EE | -32.7 to +14.0 mm/Hg (-17.5 to +7.5 in/H2O) | Varies |
| Fuel Tank Pressure Sensor | EE | 0-5.0 volts | Varies |
| Fuel Tank Rated Capacity | EE | 98 Liters (25.9 Gallons) or 129 Liters (34 Gallons) | Varies with fuel tank option |
| Fuel Trim Cell | Eng 1, EE, FT | 0-23 | 16, 17 |
| Fuel Trim Learn | Eng 1, EE, FT | Enabled/Disabled | Enabled (may Toggle) |
| Generator F Terminal Signal | Eng 2 | Percent | Varies |
| Generator L Terminal Signal Command | Eng 2 | ON/OFF | ON |
| HO2S Bank 1 Sensor 1 | Eng 1, EE, FT | Millivolts | 10-1,000 mV and Varying |
| HO2S Bank 1 Sensor 2 | Eng 1, FT | Millivolts | 10-1,000 mV and Varying |
| HO2S Bank 2 Sensor 1 | Eng 1, EE, FT | Millivolts | 10-1,000 mV and Varying |
| HO2S Bank 2 Sensor 2 | Eng 1, FT | Millivolts | 10-1,000 mV and Varying |
| IAC Position | Eng 1, EGR, FT | Counts | Varies |
| IAT Sensor | Eng 1, 2, EE, EGR, FT | -39 to +140°C (-38 to +284°F) | 35°C (91°F) Depends on ambient temperature |
| Ignition 1 Signal | Eng 1, 2, EE, EGR, FT | 0-25 volts | 11.5-14.5 Volts |
| Inj. PWM Bank 1 Average | Eng 2, FT, FF, FR, MF | Milliseconds | 2-6 |
| Inj. PWM Bank 2 Average | Eng 2, FT, FF, FR, MF | Milliseconds | 2-6 |
| Knock Retard | Eng 1, EGR | 0.0°-16° | 0° |
| Long Term FT Avg. Bn 1 | FT | Percentage | Near 0% |
| Long Term FT Avg. Bn 2 | FT | Percentage | Near 0% |
| Long Term FT Bank 1 | Eng 1, 2, EE, FT, FF, FR | Percentage | Near 0% |
| Long Term FT Bank 2 | Eng 1, 2, EE, FT, FF, FR | Percentage | Near 0% |
| Loop Status | Eng 1, 2, EE, EGR, FT, FF, FR | Open/Closed | Closed |
| MAF Sensor | All | Grams Per Seconds (g/s) | 1-9 g/s @ Idle (depends on altitude) 15-26 g/s @ 2,500 RPM (depends on altitude) |
| MAF Sensor | Eng 2 | 0-31,999 Hz | 2,000-3,000 Hz |
| MAP Sensor | All | kPa | 20-48 kPa |
| MAP Sensor | Eng 1, 2 | Volts | 1.0-2.0 volts Varies with altitude |
| MIL Command | Eng 2 | Off/On | Off |
| Mileage Since DTC Cleared | Eng 2 | km/Miles | Varies |
| Misfire Counter Status | MF | Normal/Invalid | Normal |
| Misfire Current Cyl. 1-6 | MF | 0-200 Counts | 0 |
| Misfire History Cyl. 1-6 | MF | 0-65,535 Counts | 0 |
| PCM Reset | Eng 1, 2, EGR, EE, FT | Yes/No | No |
| PCM/VCM in VTD Fail Enable | Eng 1 | Yes/No | No |
| Short Trim FT Avg. Bn1 | FT | Percentage | Near 0% |
| Short Trim FT Avg. Bn2 | FT | Percentage | Near 0% |
| Short Term FT Bank 1 | Eng 1, 2, EE, FT, FF, FR | Percentage | Near 0% |
| Short Term FT Bank 2 | Eng 1, 2, EE, FT, FF, FR | Percentage | Near 0% |
| Spark | Eng 1, 2, FT, MF | Degrees | 15°-20° |
| Start Up ECT | Eng 2, EE, FT, FF, FR | °C/°F | Varies |
| Stoplamp Pedal Switch | Eng 1, 2 | Applied/Released | Released |
| Torque Request Signal | Eng 2 | Nm | - |
| Torque Request Signal | Eng 2 | Nm | - |
| TCC Enable Solenoid Command | Eng 1, 2, MF, FF, FR | ON/OFF | OFF |
| TCC PWM Solenoid Command | Eng 2 | ON/OFF | OFF |
| TP Sensor | Eng 1, 2, EE, FT, MF, EGR, FF, FR | 0-100% | 0% |
| TP Sensor | Eng 1, 2 | 0-5.0 volts | .4-.9 volts |
| TFP Switch | Eng 2, EGR, FT | Transmission Gear Position | Varies |
| TR Switch | Eng 2, EGR, FT | Transmission Gear Position | Varies |
| Vehicle Speed Sensor | All | km/h mph |
0 |
| VTD Auto Learn Timer | Eng 1, FF, FR | Active/Inactive | Inactive |
| VTD Fuel Disable | Eng 1 | Active/Inactive | Inactive |
| VTD Fuel Disable Until Ign. Off | Eng 1 | Yes/No | No |
| Warm-Ups w/o Emission Faults | Eng 2 | 0-255 Counts | Varies |
| Warm-Ups w/o Non-Emission Faults | Eng 2 | 0-255 Counts | Varies |
NO RELATED
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.