Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
SYS.OK|MANUAL.DBβ LIVE
HOMESERVICE MANUALSCHEVROLET2006CHEVY EXPRESS G2500, VAN CARGO, 6.6 2REPAIR AND DIAGNOSISEXTERNAL PAGESDIFFERENT CARSECTION 1098 (HVAC SYSTEM - AUTOMATIC)DIAGNOSTIC INFORMATION AND PROCEDURESSCAN TOOL OUTPUT CONTROLS
2006 Chevrolet Chevy Express G2500, Van Cargo, 6.6 2
Scan Tool Output Controls
2006 Chevrolet Chevy Express G2500, Van Cargo, 6.6 2SECTION Scan Tool Output Controls
WARNING: This page is about a different car, the 2007 GMC Sierra and 2007 Chevrolet Silverado. However, it is still accessible from the selected car via links, so may be relevant.
HVAC Control Module Scan Tool Output Controls
| Scan Tool Output Control | Additional Menu Selection(s) | Description |
|---|---|---|
| A/C Request | Miscellaneous Tests | When you select ON, the HVAC control module changes the state of the A/C Request parameter to ON and transmits a clutch enable message to the powertrain control module (PCM) over the class 2 serial data circuit. |
| Air Inlet Door | Motor/Actuator Tests | When you select ON, the HVAC control module commands the recirculation actuator toward the maximum door position. The actuator moves the door to the recirculation position. When you select OFF, the HVAC control module commands the recirculation actuator toward the minimum door position. The actuator moves the door to the outside air position. |
| Blower Motor | Motor/Actuator Tests | When you select ON, the HVAC control module commands the blower motor to maximum speed. The blower motor operates at maximum speed until you select OFF. The HVAC control module must be in the ON state before selecting the output control. |
| HVAC Actuator Recalibration | - | When you select RESET, the HVAC control module recalibrates the maximum and minimum door positions of each HVAC door. The ambient air temperature display is set to the current value of the Outside Air Temp. Raw parameter. |
| Inside Air Temperature Fan | Motor/Actuator Tests | When you select OFF, the HVAC control module commands the inside air temperature fan OFF. The fan remains OFF until you select ON. The normal state of the inside air temperature fan is ON. |
| Left Mix Motor | Motor/Actuator Tests | When you select ON, the HVAC control module commands the left air temperature actuator toward the maximum door position. The actuator moves the door to the full hot position. When you select OFF, the HVAC control module commands the left air temperature actuator toward the minimum door position. The actuator moves the door to the full cold position. |
| Mode Door Position | Motor/Actuator Tests | When you select ON, the HVAC control module commands the mode actuator toward the maximum door position. The actuator moves the door to the panel position. When you select OFF, the HVAC control module commands the mode actuator toward the minimum door position. The actuator moves the door to the floor position. |
| Right Mix Motor | Motor/Actuator Tests | When you select ON, the HVAC control module commands the right air temperature actuator toward the maximum door position. The actuator moves the door to the full cold position. When you select OFF, the HVAC control module commands the right air temperature actuator toward the minimum door position. The actuator moves the door to the full hot position. |
PCM Scan Tool Output Controls
| Scan Tool Output Control | Additional Menu Selection(s) | Description |
|---|---|---|
| A/C Relay | Engine Output Controls | The engine must be running and the PCM must receive an A/C request from the HVAC control module in order to enable the output control. The PCM de-energizes the A/C compressor clutch relay when you select OFF. The relay remains de-energized until you select ON. |
Rear HVAC/RSA Module
| Scan Tool Output Control | Additional Menu Selections | Description |
|---|---|---|
| Displays(s) Test | Special Functions | The Rear HVAC/RSA module will illuminate all indicators and display segments on the module display. |
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.