Charge Mode

2006 Chevrolet Cab & Chassis Silverado 2D Pickup, 8.1 G, 4WD, AutomaticSECTION Charge Mode

The generator battery control module will enter Charge Mode when at least one of the following conditions is met:

  • The electric cooling fans are on high speed.
  • The rear defogger is ON.
  • The battery state of charge is less than 80 percent.
  • The battery current is not between -8 and 15 amps.
  • The estimated ambient air temperature is less than 0Β°C.
  • DTC B1516 is set.

Once one of these conditions are met the generator battery control module will set the targeted generator output voltage to the nominal optimum battery voltage which is from 13.9-15.5 volts, the voltage set point is based on the batteries state of charge and estimated battery temperature. The battery voltage ramps up to the targeted set point at a rate of 20 mV per second.