Blower Motor Does Not Operate In High Speed

1995 Chevrolet Blazer 4D Utility, AWDSECTION Blower Motor Does Not Operate In High Speed
  1. Turn ignition switch to RUN position. Place mode selector in VENT position. Place blower switch in HIGH position. Connect test light from Orange wire at blower motor relay connector to ground. If test light glows, go to next step. If test light does not glow, check for poor connection at blower switch connector. If connection is okay, replace blower switch.
  2. Connect test light from Red wire at blower motor relay connector to ground. If test light does not glow, repair open Red wire between blower motor relay connector and battery junction block. If test light glows, check for poor connection at blower motor relay connector or open Black wire between blower motor relay connector and ground. If connection and wire are okay, replace blower motor relay.