Oil Pump Rotor & Slide End Clearance Check

1986 Chevrolet Caprice Wagon V8-307 5.0LSECTION Oil Pump Rotor & Slide End Clearance Check





Note: Do not service oil pump rotor and slide if either pump body or pump cover surfaces are damaged. Only service the rotor and slide if parts show signs of wear.

1. Using a suitable vernier micrometer, measure thickness of pump rotor and slide. Take measurements on flat undamaged surfaces.

2. Using measurements obtained in step 1, refer to Figure for service replacement parts. Replacement parts will provide the same clearance as the original oil pump assembly. Proper en clearance should be 0.0008-0.002 inch. This clearance cannot be measured with a feeler gauge.

3. Using a fine oil stone, remove any burrs on the replacement rotor and slide, then measure parts with a vernier micrometer to assure proper thickness. Incorrect rotor thickness could result in a damaged oil pump assembly and/or low oil pressure. Incorrect slide thickness could result in incorrect transmission line pressure.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.