Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
SYS.OK|MANUAL.DB● LIVE
HOMESERVICE MANUALSCHEVROLET1985FORWARD CONTROL 6.2 J, STANDARDREPAIR AND DIAGNOSIS (SINGLE PAGE)ENGINE PERFORMANCESYSTEMCARBURETOR - ROCHESTER M4M SERIES 4-BBLSPECIFICATIONS
1985 Chevrolet Forward Control 6.2 J, Standard
Carburetor - ROCHESTER M4M Series 4-Bbl: Specifications
1985 Chevrolet Forward Control 6.2 J, StandardSECTION Specifications
CARBURETOR ADJUSTMENT SPECIFICATIONS
| Application (Carb. No.) | Specification | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| 17084500 | |||||||||
| Float Level | 12/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 37° | ||||||||
| Vacuum Break | |||||||||
| Primary | 23° | ||||||||
| Secondary | 30° | ||||||||
| Air Valve Spring (1) | 1 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 40° | ||||||||
| 17084502 | |||||||||
| Float Level | 12/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 46° | ||||||||
| Vacuum Break | |||||||||
| Primary | 24° | ||||||||
| Secondary | 30° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 40° | ||||||||
| 17085206 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 46° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 26° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085208 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | 26° | ||||||||
| Secondary | 38° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085209 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 3/8" | ||||||||
| Hole | Outer | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | 26° | ||||||||
| Secondary | 36° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085210 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | 26° | ||||||||
| Secondary | 38° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085211 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 3/8" | ||||||||
| Hole | Outer | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | 26° | ||||||||
| Secondary | 36° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085213 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 46° | ||||||||
| Vacuum Break | |||||||||
| Primary | 23° | ||||||||
| Secondary | N/A | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 35° | ||||||||
| 17085215 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 46° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 26° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 32° | ||||||||
| 17085220 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 3/8" | ||||||||
| Hole | Outer | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 26° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 32° | ||||||||
| 17085221 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 3/8" | ||||||||
| Hole | Outer | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 26° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 32° | ||||||||
| 17085222 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | 26° | ||||||||
| Secondary | 36° | ||||||||
| Air Valve Spring (1) | 1/2 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085223 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 3/8" | ||||||||
| Hole | Outer | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | 26° | ||||||||
| Secondary | 36° | ||||||||
| Air Valve Spring (1) | 1/2 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085224 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | 26° | ||||||||
| Secondary | 36° | ||||||||
| Air Valve Spring (1) | 1/2 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085225 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 3/8" | ||||||||
| Hole | Outer | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | 26° | ||||||||
| Secondary | 36° | ||||||||
| Air Valve Spring (1) | 1/2 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085226 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 24° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 32° | ||||||||
| 17085227 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 24° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 32° | ||||||||
| 17085228 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 46° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 24° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085229 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 46° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 24° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085230 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 26° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 32° | ||||||||
| 17085231 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 26° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 32° | ||||||||
| 17085235 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 46° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 26° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085238 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 3/8" | ||||||||
| Hole | Outer | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 26° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 32° | ||||||||
| 17085239 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 3/8" | ||||||||
| Hole | Outer | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 26° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 32° | ||||||||
| 17085290 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 46° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 24° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085291 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 3/8" | ||||||||
| Hole | Outer | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 46° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 26° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085292 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 46° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 24° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085293 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 3/8" | ||||||||
| Hole | Outer | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 46° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 26° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085294 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 46° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 26° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085298 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | 9/32" | ||||||||
| Hole | Inner | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 46° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 26° | ||||||||
| Air Valve Spring (1) | 7/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 39° | ||||||||
| 17085408 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | N/A | ||||||||
| Hole | (2) | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 27° | ||||||||
| Air Valve Spring (1) | 1/2 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 38° | ||||||||
| 17085409 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | N/A | ||||||||
| Hole | (2) | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 27° | ||||||||
| Air Valve Spring (1) | 5/8 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 38° | ||||||||
| 17085415 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | N/A | ||||||||
| Hole | (2) | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 27° | ||||||||
| Air Valve Spring (1) | 1/2 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 38° | ||||||||
| 17085417 | |||||||||
| Float Level | 13/32" | ||||||||
| Accelerator Pump | |||||||||
| Stem | N/A | ||||||||
| Hole | (2) | ||||||||
| Choke Coil Lever | .120" | ||||||||
| Choke Rod | 20° | ||||||||
| Vacuum Break | |||||||||
| Primary | N/A | ||||||||
| Secondary | 27° | ||||||||
| Air Valve Spring (1) | 3/4 | ||||||||
| Auto. Choke | (3) TR | ||||||||
| Choke Unloader | 38° | ||||||||
|
|||||||||
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.