Scan Tool Data List

2011 Cadillac Escalade Base, AWDSECTION Scan Tool Data List
WARNING: This page is about a different car, the 2007 GMC Sierra and 2007 Chevrolet Silverado. However, it is still accessible from the selected car via links, so may be relevant.
Scan Tool Data List

Scan Tool Parameter Data List Units Displayed Typical Data Value
Engine is at Idle, Upper Radiator Hose is Hot, Closed Throttle, Gear is in PARK, and Accessories are OFF.
1-2 Adapt Status Cell 0 F4 Fast/Slow Varies
1-2 Adapt Status Cell 1 F4 Fast/Slow Varies
1-2 Adapt Status Cell 2 F4 Fast/Slow Varies
1-2 TAP Cell 1 F4 PSI Varies
1-2 TAP Cell 2 F4 PSI Varies
1-2 TAP Cell 3 F4 PSI Varies
1-2 TAP Cell 4 F4 PSI Varies
2-1 Adapt Status 0% Throttle F4 Fast/Slow Varies
2-1 Adapt Status Full Throttle F4 Fast/Slow Varies
2-1 Adapt Status Lift Foot F4 Fast/Slow Varies
2-1 Adapt Status Part Throttle F4 Fast/Slow Varies
2-1 Adapt Status Pre-Select F4 Fast/Slow Varies
2-1 TAP Cell 1 F4 PSI Varies
2-1 TAP Cell 2 F4 PSI Varies
2-1 TAP Cell 3 F4 PSI Varies
2-1 TAP Cell 4 F4 PSI Varies
2-1 TAP Cell 5 F4 PSI Varies
2-1 TAP Cell 6 F4 PSI Varies
2-1 TAP Cell 7 F4 PSI Varies
2-1 TAP Cell 8 F4 PSI Varies
2-1 TAP Cell 9 F4 PSI Varies
2-1 TAV Cell 1 F4 CM3 Varies
2-1 TAV Cell 2 F4 CM3 Varies
2-3 Adapt Status Cell 0 F5 Fast/Slow Varies
2-3 Adapt Status Cell 1 F5 Fast/Slow Varies
2-3 Adapt Status Cell 2 F5 Fast/Slow Varies
2-3 TAP Cell 1 F5 PSI Varies
2-3 TAP Cell 2 F5 PSI Varies
2-3 TAP Cell 3 F5 PSI Varies
2-3 TAP Cell 4 F5 PSI Varies
3-2 Adapt Status 0% Throttle F5 Fast/Slow Varies
3-2 Adapt Status Full Throttle F5 Fast/Slow Varies
3-2 Adapt Status Lift Foot F5 Fast/Slow Varies
3-2 Adapt Status Part Throttle F5 Fast/Slow Varies
3-2 Adapt Status Pre-Select F5 Fast/Slow Varies
3-2 TAP Cell 1 F5 PSI Varies
3-2 TAP Cell 2 F5 PSI Varies
3-2 TAP Cell 3 F5 PSI Varies
3-2 TAP Cell 4 F5 PSI Varies
3-2 TAP Cell 5 F5 PSI Varies
3-2 TAP Cell 6 F5 PSI Varies
3-2 TAP Cell 7 F5 PSI Varies
3-2 TAP Cell 8 F5 PSI Varies
3-2 TAP Cell 9 F5 PSI Varies
3-2 TAV Cell 1 F5 CM3 Varies
3-2 TAV Cell 2 F5 CM3 Varies
3-4 Adapt Status Cell 0 F6 Fast/Slow Varies
3-4 Adapt Status Cell 1 F6 Fast/Slow Varies
3-4 Adapt Status Cell 2 F6 Fast/Slow Varies
3-4 TAP Cell 1 F6 PSI Varies
3-4 TAP Cell 2 F6 PSI Varies
3-4 TAP Cell 3 F6 PSI Varies
3-4 TAP Cell 4 F6 PSI Varies
4-3 Adapt Status 0% Throttle F6 Fast/Slow Varies
4-3 Adapt Status Full Throttle F6 Fast/Slow Varies
4-3 Adapt Status Lift Foot F6 Fast/Slow Varies
4-3 Adapt Status Part Throttle F6 Fast/Slow Varies
4-3 Adapt Status Pre-Select F6 Fast/Slow Varies
4-3 TAP Cell 1 F6 PSI Varies
4-3 TAP Cell 2 F6 PSI Varies
4-3 TAP Cell 3 F6 PSI Varies
4-3 TAP Cell 4 F6 PSI Varies
4-3 TAP Cell 5 F6 PSI Varies
4-3 TAP Cell 6 F6 PSI Varies
4-3 TAP Cell 7 F6 PSI Varies
4-3 TAP Cell 8 F6 PSI Varies
4-3 TAP Cell 9 F6 PSI Varies
4-3 TAV Cell 1 F6 CM3 Varies
4-3 TAV Cell 2 F6 CM3 Varies
4-5 Adapt Status Cell 0 F7 Fast/Slow Varies
4-5 Adapt Status Cell 1 F7 Fast/Slow Varies
4-5 Adapt Status Cell 2 F7 Fast/Slow Varies
4-5 TAP Cell 1 F7 PSI Varies
4-5 TAP Cell 2 F7 PSI Varies
4-5 TAP Cell 3 F7 PSI Varies
4-5 TAP Cell 4 F7 PSI Varies
5-4 Adapt Status 0% Throttle F7 Fast/Slow Varies
5-4 Adapt Status Full Throttle F7 Fast/Slow Varies
5-4 Adapt Status Lift Foot F7 Fast/Slow Varies
5-4 Adapt Status Part Throttle F7 Fast/Slow Varies
5-4 Adapt Status Pre-Select F7 Fast/Slow Varies
5-4 TAP Cell 1 F7 PSI Varies
5-4 TAP Cell 2 F7 PSI Varies
5-4 TAP Cell 3 F7 PSI Varies
5-4 TAP Cell 4 F7 PSI Varies
5-4 TAP Cell 5 F7 PSI Varies
5-4 TAP Cell 6 F7 PSI Varies
5-4 TAP Cell 7 F7 PSI Varies
5-4 TAP Cell 8 F7 PSI Varies
5-4 TAP Cell 9 F7 PSI Varies
5-4 TAV Cell 1 F7 CM3 Varies
5-4 TAV Cell 2 F7 CM3 Varies
4WD Low F0 Enabled/Disabled Disabled
Cold Shift Pattern F2 Disabled/Enabled Disabled
Current Gear F0, F1, F2, F3 0-7 0
Driver Demanded Engine Torque F0, F2, F4, F5, F6, F7, F8 N.m (lb ft) 0
Driver-Reverse Adapt Status Cell 0 F8 Numeric Value Varies
ECT F0, F1 °C (°F) Varies
Engine Run Time F0, F1, F2, F3, F4, F5, F6, F7, F8 Hr:Min:Sec Varies
Engine Torque F0, F1, F2, F4, F5, F6, F7, F8 N.m (lb ft) 10
Force Motor Solenoid 1 Enabled F3 Yes/No Yes
Forced Motor Solenoid 2 Enabled F3 Yes/No Yes
Gear Commanded F0, F1, F2, F3 0-7 0
Gear Ratio F0, F1, F2, F4, F5, F6, F7, F8 Ratio -
Gear Selected F0, F1, F2, F3 0-8 8
GS Delay From Drive 4 to R Cell 3 F8 Seconds Varies
GS Delay From Reverse to D 1 Cell 3 F8 Seconds Varies
GS TAP From Drive 4 to R Cell 1 F8 PSI Varies
GS TAP From Neutral to D 1 Cell 1 F8 PSI Varies
GS TAP From Neutral to R Cell 1 F8 PSI Varies
GS TAP From Reverse to D 1 Cell 1 F8 PSI Varies
GS TAP From Reverse to N Cell 2 F8 PSI Varies
GS TAV From Drive 4 to R Cell 1 F8 CM3 Varies
GS TAV From Drive 4 to R Cell 2 F8 CM3 Varies
GS TAV From Neutral to D 1 Cell 1 F8 CM3 Varies
GS TAV From Neutral to D 1 Cell 2 F8 CM3 Varies
GS TAV From Neutral to R Cell 1 F8 CM3 Varies
GS TAV From Neutral to R Cell 2 F8 CM3 Varies
GS TAV From Reverse to D 1 Cell 1 F8 CM3 Varies
GS TAV From Reverse to D 1 Cell 2 F8 CM3 Varies
Ignition Voltage F0 Volts 14.00
Last Output Speed Range Shift F2, F4, F5, F6, F7, F8 RPM Varies
Neutral-First Adapt Status Cell 0 F8 Slow/Fast Varies
Neutral-Reverse Adapt Status Cell 0 F8 Slow/Fast Varies
Neutral-Second Adapt Status Cell 0 F8 Slow/Fast Varies
Next Output Speed for Downshift F0, F2, F4, F5, F6, F7, F8 RPM 0
Next Output Speed Upshift F0, F2, F4, F5, F6, F7, F8 RPM Varies
Normal Shift Pattern F2 Enabled/Disabled Enabled
PC Sol. 1 Actual Current F0, F3 Amps Varies
PC Sol. 1 Ref. Current F0, F3 Amps Varies
PC Sol. 2 Actual Current F0, F3 Amps Varies
PC Sol. 2 Ref. Current F0, F3 Amps Varies
PC Solenoid 1 Duty Cycle F0, F3 % 0%
PC Solenoid 2 Duty Cycle F0, F3 % 0%
Previous Gear F0, F1, F2, F3 0-7 0
Requested Torque F4, F5, F6, F7, F8 Numeric Value Varies
Reverse-First Adapt Status Cell 0 F8 Fast/Slow Varies
Reverse-Second Adapt Status Cell 0 F8 Fast/Slow Varies
Service Brake Status Inverted F0, F1 Enabled/Disabled Enabled
Shift Solenoid 1 F0, F2 On/Off On
Shift Solenoid 2 F0, F2 On/Off On
Shift Solenoid 3 F0, F2 On/Off On
Shift Solenoid 1 Open/Short to GND F2 Yes/No No
Shift Solenoid 1 Short to Volts F2 Yes/No No
Shift Solenoid 2 Open/Short to GND F2 Yes/No No
Shift Solenoid 2 Short to Volts F2 Yes/No No
Shift Solenoid 3 Open/Short to GND F2 Yes/No No
Shift Solenoid 3 Short to Volts F2 Yes/No No
TCC Duty Cycle F0, F1 % 0%
TCC Duty Cycle Open/Short to GND F1 Yes/No No
TCC Duty Cycle Short to Volts F1 Yes/No No
TCC Slip Speed F0, F1 RPM Varies
TFP Sw. C/D/E/R F0 On/Off -
Torque Management Duty Cycle F0, F2 % DC Varies
Tow/Haul Mode F0 Inactive/Active Inactive
Torque Requested F0, F2 N.m (lb ft) 0
TP Angle F0, F1, F2, F3, F4, F5, F6, F7, F8 Percent 0%
TR Sw. F0 Park, Reverse, Neutral, Drive, 4,3,2,1 Park
TR Sw. A/B/C/P F0 On/Off Off/On/On/Off
Trans. Fluid Temp. F0, F1, F2, F3, F4, F5, F6, F7, F8 °C (°F) Varies
Transmission Hot Mode F0, F1 On/Off Off
Transmission ISS F0, F1, F2, F3, F4, F5, F6, F7, F8 RPM 600-800
Transmission OSS F0, F1, F2, F3, F4, F5, F6, F7, F8 RPM 0
Turbine Speed F0, F1, F2, F3, F4, F5, F6, F7, F8 RPM 600-800
Data List Legend
  • F0: Trans. Data
  • F1: TCC Data
  • F2: Shift Data
  • F3: PC Solenoid Data
  • F4: 1-2 Adapt. Data
  • F5: 2-3 Adapt. Data
  • F6: 3-4 Adapt. Data
  • F7: 4-5 Adapt. Data
  • F8: Garage Shift Adapt. Data
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.