Circuit/System Testing

2013 Buick Regal Turbo Premium, Standard TransSECTION Circuit/System Testing
WARNING: This page is about a different car, the 2012 Buick Regal. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ignition OFF and all vehicle systems OFF. Disconnect the B108 air quality sensor. It may take up to 2 minutes for all vehicle systems to power down.
  2. Test for less than 10 Ω between the ground circuit terminal 2 and ground.
    • If 10 Ω or greater 
    1. Ignition OFF.
    2. Test for less than 2 Ω in the ground circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, repair the open/high resistance in the ground connection.
    • If less than 10 Ω 
  3. Ignition ON.
  4. Verify a test lamp illuminates between the ignition circuit terminal 1 and ground.
    • If the test lamp does not illuminate and the circuit fuse is good 
    1. Ignition OFF.
    2. Test for less than 2 Ω in the ignition circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, verify the fuse is OK and there is voltage at the fuse.
    • If the test lamp does not illuminate and the circuit fuse is open 
    1. Ignition OFF.
    2. Test for infinite resistance between the ignition circuit and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
      • If infinite resistance, replace the B108 air quality sensor.
    • If the test lamp illuminates 
  5. Verify the scan tool Odor Sensor parameter is greater than 95%.
    • If 95% or less 
    1. Ignition OFF, disconnect the harness connector at the K33 HVAC control module.
    2. Test for infinite resistance between the signal circuit terminal 3 and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
      • If infinite resistance, replace the K33 HVACcontrol module.
    • If greater than 95% 
  6. Install a 3 A fused jumper wire between the signal circuit terminal 3 and the low reference circuit terminal 2.
  7. Verify the scan tool Odor Sensor parameter is less than 5%.
    • If 5% or greater 
    1. Ignition OFF, disconnect the harness connector at the K33 HVAC control module, ignition ON.
    2. Test for less than 1 V between the signal circuit terminal 3 and ground.
      • If 1 V or greater, repair the short to voltage on the circuit.
      • If less than 1 V
    3. Ignition OFF
    4. Test for less than 2 Ω in the signal circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, replace the K33 HVAC control module.
    • If less than 5% 
  8. If all circuits test normal, replace the B108 air quality sensor.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.