Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Code A013: Left Front Release Solenoid Open Or Shorted To Ground
When front enable relay is energized, voltage is applied to left front solenoid. To activate left front release solenoid, the anti-lock brake controller grounds terminal "C" of left front solenoid. To set Code A013, the following conditions must occur.
- Front enable relay is energized.
- Left front release solenoid control is open.
- Anti-lock brake controller senses no voltage at terminal 1C3.
- If Code A010 is set, power feed to left front solenoid is open.
- Tech I (94-00101-A) scanner will display HI feedback if voltage is available at terminal 1C3.
- A short to ground exists if test light is on.
- If a short to ground does not exists with anti-lock brake controller disconnected, replace unit.
- If test light is on, Brown wire between left front solenoid and front enable relay is okay.
- If continuity to ground through front enable relay contacts is present, open is in anti-lock brake controller.
- Isolate open in solenoid or circuit No. 862.
NO RELATED
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.