61 20 908 Performing Battery "Power Reset" (For Programming/Coding Control Unit (S))

2010 BMW 128i 2D Coupe, N52, AutomaticSECTION 61 20 908 Performing Battery "Power Reset" (For Programming/Coding Control Unit (S))
IMPORTANT: Observe safety instructionsΒ Β  for handling vehicle battery.Β 

The following steps must be carried out for a "power reset":Β 

  • Switch off and disconnect battery charger
  • Switch off ignition

    Cars with ignition key:Β  Turn ignition key to 0 position

    Cars with identification sensor:Β  Remove identification sensor from slot

    Cars with comfort access system:Β  Make sure terminal is in 0 position

  • Disconnect battery negative terminal
  • Reconnect battery negative terminal (to ensure bus activity)
  • Waiting time (5-10 seconds)
  • Disconnect battery negative terminal
  • Waiting time (1 minute)
  • Connect battery negative terminal and tighten, tightening torque: see 61 21 1AZ in 61 21 BATTERY WITH TERMINAL .
  • Connect and switch on battery charger
  • Switch ignition on
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.