Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Calibration Requirements
- The camera lens must be clean. Cleaning
- Check the camera images on the Front Information Display Control Head -J685-. Replace the camera if the images are unclear because the camera has been damaged. Check the mount for the camera if the image is low.
- Make sure both exterior rearview mirrors are folded out.
- The vehicle must be standing on a firm and level surface.
- There must be enough clearance around the vehicle (at least 2 meters).
- The parking brake must be set.
- The steering wheel must be in the 0 position and the wheels must be straight.
- If the vehicle has an air suspension, turn on "Auto" and drive the vehicle at "standard vehicle height" onto Vehicle Diagnostic Tester.
- All doors and the rear lid must be closed.
- No one should be in the vehicle.
- The vehicle must not be loaded (curb weight).
- Connect the battery charger.
- Ignition switched on.
- The system is active and is displayed on the Front Information Display Control Head -J685-.
- Do not move the vehicle during the calibration process.
Calibrate the cameras in the following sequence:
- Front Peripheral Camera -R243-
- Rear Peripheral Camera -R246-
- Left Peripheral Camera -R244-
- Right Peripheral Camera -R245-
Special tools and workshop equipment requiredΒ
- Calibration ToolVAS6350
- Peripheral Camera Calibration DeviceVAS6350/6
- Vehicle Diagnostic Tester
The Calibration ToolVAS6350 consists of the following parts:
- Calibration field
- Calibration Tool - Wheel Center MountingsVAS6350/1
- Calibration Tool - Spacing LaserVAS6350/2
- Linear LaserVAS6350/3A
The Peripheral Camera Calibration DeviceVAS6350/6 is comprise of the following components:
- Mounting Post with Left PlateVAS6350/6-1
- Mounting Post with Right PlateVAS6350/6-2
- Left Post MountVAS6350/6-3
- Right Post MountVAS6350/6-4
- Guide PinVAS6350/6-5
- Line Scan Laser MountVAS6350/6-6
Overview Calibration ToolVAS6350 with Peripheral Camera Calibration DeviceVAS6350/6
The Mounting Post with Left PlateVAS6350/6-1 and Mounting Post with Right PlateVAS6350/6-2 must be vertical.
-- Move the calibration field on the Peripheral Camera Calibration DeviceVAS6350/6 into a horizontal position.
-- To do this, twist plastic feet under the calibration field of the Calibration ToolVAS6350 so that air bubble in level is located exactly in the center of the indicator -arrow-
NO RELATED
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.