Oxygen Sensor After Catalytic Converter, Checking

2008 Audi A3 Base, 2.0 E, Automatic DCTSECTION Oxygen Sensor After Catalytic Converter, Checking

Observe all safety precautions: SAFETY PRECAUTIONS 

View clean working conditions: CLEAN WORKING CONDITIONS 

Prior to repair work, perform a preliminary check to verify the condition. Refer to PRELIMINARY CHECK .

Use only gold-plated terminals when servicing any component with gold-plated electrical harness connector terminals.

For wiring diagrams, component locations, and connector views, Refer to the applicable wiring diagram.

Special tools and workshop equipment required 

  • Generic scan tool
  • Multimeter
  • Wiring diagram

Test requirements 

  • The oxygen sensor properly installed
  • Exhaust system free of leaks
  • The oxygen sensor fuses OK
  • Ground connections between engine/transmission/chassis OK
  • Battery voltage at least 12.5 volts
  • Coolant temperature at least 80° C
  • All electrical consumers switched off
  • Vehicles with automatic transmission, shift selector lever in park or neutral
  • A/C switched off
  • Engine running
NOTE:

The oxygen sensor compares the oxygen content of the outside air with the residual oxygen content in the exhaust gas, and generates a voltage input signal to the engine control module.

If oxygen sensor voltage does not fluctuate, the sensor does not respond, or responds too slowly, the following causes are possible:

Slits in the oxygen sensor tip are plugged

Sensor not up to operating temperature

Sensor has been thermally overloaded

Transition resistance in signal wire or reference ground connection

Sensor has been damaged by electrical contact cleaner or similar contaminant (drawn through signal wire by capillary action due to thermal fluctuation)

Sensor has been damaged by exposure to silicone. When using silicone sprays and sealants, silicone residue is drawn into the engine where it passes unburned into the exhaust and can damage the oxygen sensor

Test procedure 

-- Using a generic scan tool, refer to Diagnostic Mode 05 - Read Current System Data.

NOTE:

Mode 05 may not be supported on all systems. On systems where Diagnostic Mode 05 is not supported, refer to Diagnostic Mode 6 for oxygen sensor monitoring test results.

-- Check the specified values at idle and compare the results to the min. / max. values given in the Mode 6 table.

-- Switch ignition off.

If the specified value was obtained:

If the test results indicate no monitor failures: The fault is not active at this time.

-- Check the wiring connection for damage, corrosion, loose or broken terminals.

-- If necessary, repair the faulty wiring connection.

-- Go to Final procedures

If the specified value was Not obtained:

Checking primary voltage 

-- Remove the right vehicle floor cover -arrows-. Refer to the appropriate service information.

Fig 1: Identifying Right Vehicle Floor Cover
GWWA10-1663Courtesy of AUDI OF AMERICA, LLC

-- Disconnect the oxygen sensor electrical harness connector. Oxygen sensor after three way catalytic converter - G130- Refer to the service information for removal and installation procedures.

Fig 2: Disconnecting Connector For Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) G130
GWWA26-10132Courtesy of AUDI OF AMERICA, LLC

-- Switch ignition on.

-- Using a Multimeter, check the Oxygen sensor after three way catalytic converter - G130- electrical harness connector terminals 3 to 4 for voltage.

Fig 3: Checking Component Terminals 3 To 4 For Voltage
GWWN24-0731Courtesy of AUDI OF AMERICA, LLC
  • Specification: 0.400 to 0.500 V

-- Switch ignition off.

If the specified value was obtained:

-- Replace the oxygen sensor. Refer to the appropriate service information for removal and installation procedures.

-- Go to Final procedures

If the specified value was Not obtained:

Checking wiring and connections 

If the manufacturers test box is being used, perform the following step.

-- Install the test box.

If the manufacturers test box is not being used, perform the following step.

-- Remove the engine control module. Refer to the service information for removal and installation procedures.

-- Using a Multimeter, measure the resistance of the signal and reference ground circuits between the oxygen sensor and the engine control module. Refer to the applicable wiring diagram.

Oxygen sensor after three way catalytic converter - G130- electrical harness connector terminals Motronic Engine Control Module (ECM) - J623- electrical connector T94 terminals or test box sockets
3 34
4 62

Specified value: 1.5 Ω max.

If the specified value was Not obtained:

-- Check the circuits for a short to each other, short to battery voltage, and short to ground.

-- Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-- Repair the wiring or connection as necessary.

-- Go to Final procedures

If the specified value was obtained:

-- Check the wiring connection for damage, corrosion, loose or broken terminals.

-- If necessary, repair the faulty wiring connections, if no faults were found.

-- Replace the engine control module. Motronic Engine Control Module (ECM) - J623- Refer to the service information for removal and installation procedures.

Final procedures 

-- Reinstall the right vehicle floor cover. Refer to the appropriate service information.

-- After the repair work, the following work steps must be performed in the following sequence:

  1. Check the DTC memory. Refer to DIAGNOSTIC MODE 03 - READ DTC MEMORY .
  2. If necessary, erase the DTC memory. Refer to DIAGNOSTIC MODE 04 - ERASE DTC MEMORY .
  3. If the DTC memory was erased, generate readiness code. Refer to READINESS CODE .
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.