Test requirement
- Engine coolant temperature at least 85 °C (185 °F)

Checking
- Connect VAG 1551 (VAG 1552) Scan Tool (ST), and press buttons -0- and -1- to insert "Engine Electronics" address word 01 (engine running at idle). Testing and Inspection

Indicated on display

Rapid data transfer HELP
Selecting function XX


- Press buttons -0- and -8- to select "Read Measuring Value Block" function 08, and press -Q- button to confirm input.

Indicated on display

Read Measuring Value Block
Input display group number XXX


- Press buttons -0-, -3- and -5- to input display group number 35, and press -Q- button to confirm input.

Indicated on display

Read Measuring Value Block 35 ->
1 2 3 4


- Check specified values for air control valve for fuel injectors (air-shrouded fuel injectors), display field 4:





Specified value in display field 4: A-IV OK

If display is not as specified:
- Press -4- button on VAG 1551 scan tool to select "Basic Setting" function 04.
- Check specified values for air control valve for fuel injectors (air-shrouded fuel injectors), display fields 2 and 4:





If display is not as specified:
- Check air lines for blockage.
- Check air control valve for fuel injectors.
- Press -> button to advance program sequence.
- Press buttons -0- and -6- to select "End Output" function 06, and press -Q- button to confirm input.


RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.