Read Measuring Block Value Overview

1995 Audi 90 Quattro Sport V6-2.8L (AAH)SECTION Read Measuring Block Value Overview
The "Read Measuring Value Block" function is an effective troubleshooting aid. The display groups are used for troubleshooting driveability problems and special component malfunctions. A number of actual values can be checked under the current operating conditions of the vehicle.
Measuring block values are displayed in 10 display fields (display group 000) or in four display fields (display groups 001 to 022)
When display groups 001 to 022 are shown, the physical units such as RPM or °C are also displayed.
Values and specifications in each display field are identical to those for "Basic Setting" function 04, except the EVAP cannister purge control valve is fully operational.
If display groups are selected that are not assigned (e.g. 23-98), "Function is unknown or cannot be carried out at the moment" will be displayed.
Operation with Oxygen Sensor control switched OFF is possible as a special case in display group 099.

Possible operating conditions:
^ Ignition switched ON (engine NOT running)
^ Closed throttle position (idle, engine warm)
^ Vehicle under load (test drive)

CAUTION!:
When test driving the vehicle to evaluate or troubleshoot, always use a second person to operate VAG Scan Tool.

The measuring values should first be read and printed out with "Read Measuring Value Block" function 08.

If necessary for troubleshooting the measuring values can also be displayed and printed out in "Basic Setting" function 04 (e.g. oxygen sensor learning values). When function 04 is selected, the influence of the EVAP canister among other things, is ruled out).

Measuring Value Blocks:




General overview of display groups 000 - 022

Overview Of Display Groups 000 - 003:




Overview of display fields in groups 000 - 003

Overview Of Display Groups 004 - 009:




Overview of display fields in groups 004 - 009

Overview Of Display Groups 010 - 015:




Overview of display fields in groups 010 - 015

Overview Of Groups 016 - 021:




Overview of display fields in groups 016 - 021

Overview Of Display Group 022:




Overview of display fields in group 022

Overview Of Display Group 099:




Overview of display fields in group 099

NOTE: Oxygen Sensor (02S) control can be switched OFF and ON with display group 099.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.