1986 Audi Coupe AutomaticFACTORY OEM SERVICE PROCEDURE

Switching Module Test - 5000CS Turbo

  1. Check Blue wire from terminal No. 1 of ignition coil to switching module for any damage or corrosion. Repair if necessary. Using a jumper wire, connect coil tower wire to ground.
  2. Unplug connector from switching module (next to ignition coil). Connect voltmeter between terminal No. 2 (Green/White wire) and ground. See Fig 1. Install a jumper wire between terminal No. 1 and ground.
    NOTE: Ensure test lead connections are correct. If reversed, ignition control unit will be damaged.