Body Control Module Inspection

2023 Acura Integra A-Spec, Automatic CVT TransSECTION Body Control Module Inspection

Preconditions 

NOTE:

This procedure can be done before any other inspections are completed because this test procedure includes all of the following inspection items. However, if this test fails, it will be necessary to continue with each inspection item individually to determine which item failed.

  • External circuit is normal

Test Procedure 

  • Preparation
    • Rear interior LF antenna connector (2P): disconnected
  • Procedure
    • Perform the inspection according to the following table.

(Disconnected) Rear interior LF antenna connector (2P) female terminals

IG Mode

GHH655765Courtesy of HONDA, U.S.A., INC.

Normal Conditions

Module internal circuit inspection 

ON*1

Voltage 

*1: If the matter whether the vehicle mode ON or OFF (LOCK) because of the permanent power supply.

Results 

  • If it is abnormal, there is a problem with the body control module.