Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
SYS.OK|MANUAL.DBβ LIVE
HOMESERVICE MANUALSACURA2008CSX BASE, K20A3REPAIR AND DIAGNOSISEXTERNAL PAGESDIFFERENT CARSECTION 17 (CLIMATE CONTROL SYSTEM)CLIMATE CONTROLRECIRCULATION CONTROL MOTOR TEST
2008 Acura CSX Base, K20A3
Recirculation Control Motor Test
2008 Acura CSX Base, K20A3SECTION Recirculation Control Motor Test
WARNING: This page is about a different car, the 2011 Acura TL, 2010 Acura TL, and 2009 Acura TL. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
Before testing the motor, check for HVAC DTCs (see
GENERAL TROUBLESHOOTING INFORMATIONΒ )
- Disconnect the 7P connector from the recirculation control motorNOTE: Incorrectly applying power and ground to the recirculation control motor will damage it Follow the instructions carefully
- Connect battery power to terminal No 1 of the recirculation control motor, and ground terminal No 2, the recirculation control motor should run smoothly, and stop at Recirculate If it doesn't, reverse the connections, the recirculation control motor should run smoothly, and stop at Fresh When the recirculation control motor stops running, disconnect battery power immediately.
- If the recirculation control motor did not run in step 2, remove it, then check the recirculation control linkage and door for smooth movement.
- If the linkage and door move smoothly, replace the recirculation control motor (see RECIRCULATION CONTROL MOTOR REPLACEMENTΒ ).
- If the linkage or door stick or bind, repair them as needed
- If the recirculation control motor runs smoothly, go to step 4
- Use a digital multimeter with an output of 1 mA or less at the 20 kΞ© range Operate the recirculation control motor running as in step 2, and check for continuity between terminals No 3,4, and 5 and terminal No 7 individually There should be continuity for a moment at each terminal as the motor through its travel
- If there is no continuity for a moment at each terminal, replace the recirculation control motor (see RECIRCULATION CONTROL MOTOR REPLACEMENTΒ )
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.