Recirculation Control Switch

2001 Acura Integra GS, 2D Coupe, StandardSECTION Recirculation Control Switch

With fresh/recirculated air button in fresh air position, continuity should exist between terminals No. 4 and 6. See Fig 1 . With button in recirculated air position, continuity should exist between terminals No. 4 and 5. If continuity is not as specified, replace heater control panel.

Fig 1: Testing Heater Control Panel
G95F10020Courtesy of AMERICAN HONDA MOTOR CO., INC.