Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
SYS.OK|MANUAL.DB● LIVE
HOMESERVICE MANUALSACURA1998INTEGRA RS, AUTOMATICREPAIR AND DIAGNOSIS (SINGLE PAGE)ELECTRICALCHARGING SYSTEMSGENERATORS & REGULATORSON-VEHICLE TESTINGGENERATOR/REGULATOR OUTPUT TEST
1998 Acura Integra RS, Automatic
Generator/Regulator Output Test
1998 Acura Integra RS, AutomaticSECTION Generator/Regulator Output Test
- Test system using a generator tester with carbon pile. Hook up tester according to manufacturer's instructions. Start engine and operate at 3000 RPM until radiator fan comes on, then let engine idle. Increase engine speed to 2000 RPM and hold. Observe voltmeter on carbon pile. If reading is greater than 15.1 volts, replace voltage regulator. If reading is less than 15.1 volts, go to next step.
- Return engine to idle. Ensure all accessories are off. On 2.5TL, connect inductive pick-up over generator terminal "B" (battery terminal wire). See Figure . Ensure arrow on inductive pick-up points away from generator. On Integra, zero ammeter on carbon pile and connect inductive pick-up over negative battery cable. Ensure arrow points toward negative battery terminal. Increase engine speed to 2000 RPM and hold. Observe voltmeter. If reading is 13.5 volts or greater, go to next step. If reading is less than 13.5 volts, test and repair generator components as necessary. Repeat voltage test.
- While observing ammeter, apply load with generator tester carbon pile until battery voltage drops to 12-13.5 volts. If less than 75 amps exist (70 amps on Integra), go to next step. If 75 amps (70 amps or more on Integra) or more exist, charging system is functioning properly.CAUTION: Voltage will increase rapidly during full field test. DO NOT allow voltage to exceed 18 volts. Damage to electrical system may result.
- With engine speed still at 2000 RPM, full field generator. Attach a probe to the full field probe of the carbon pile. Insert test probe into full field access hole, located on back of generator. See Figure . On 2.5TL, if 75 amps or more exist, go to next step. On Integra, if 70 amps or more exist, replace voltage regulator. If less than specified amperage exists, test and repair generator components. See BENCH TESTING .
- On 2.5TL, turn ignition switch to OFF position. Disconnect generator 4-pin harness connector. Turn ignition switch to ON position. Measure voltage between ground and generator 4-pin harness connector terminal No. 1 (Black/Yellow wire). See Figure . If battery voltage exists, replace voltage regulator. If battery voltage does not exist, repair open in Black/Yellow wire.
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.