RECIRCULATION Control Motor Does Not Operate Doors

1997 Acura 2.2CL StandardSECTION RECIRCULATION Control Motor Does Not Operate Doors
  1. Check fuse No. 8 (7.5-amp) in underdash fuse/relay block. If fuse is blown, replace fuse. If necessary, repair short to ground. If fuse is okay, disconnect recirculation control motor 4-pin connector. Turn ignition on. Check for voltage between ground and Black/Yellow wire terminal of recirculation control motor 4-pin connector. If battery voltage does not exist, repair open wire between fuse No. 8 and recirculation control motor.
  2. If battery voltage exists, turn ignition off. Test recirculation control motor. See RECIRCULATION CONTROL MOTOR under TESTINGΒ  . If motor is okay, go to step 4). If motor is not okay, remove recirculation control motor. See RECIRCULATION CONTROL MOTOR under REMOVAL & INSTALLATIONΒ  .
  3. Check recirculation control linkage and doors for smooth operation. If linkage and doors are okay, replace recirculation control motor. If linkage and doors are not okay, repair control linkage and doors.
  4. Remove stereo unit and disconnect climate control unit 20-pin connector. Check for continuity between ground and terminal No. 4 (Green/Red wire) and 3 (Green/White wire) of the climate control unit 20-pin connector individually. See Figure . If continuity exists, repair shorted wire(s) between recirculation control motor and climate control unit.
  5. If continuity does not exist, check for voltage between ground and terminals No. 4 (Green/Red wire) and 3 (Green/White wire) of climate control unit 20-pin connector individually. See Figure . If voltage exists, repair short to power in wire(s) between recirculation control motor and climate control unit. If short to power exists, climate control unit must be replaced.
  6. If voltage does not exist, check for continuity in Green/White wire and Red/Green wire between recirculation control motor 4-pin connector and climate control unit 20-pin connector. If continuity does not exist, repair open in wire(s) between recirculation control motor and climate control unit.
  7. If continuity exists, check for loose wires or poor connections at climate control unit 20-pin connector and recirculation control motor 4-pin connector. If connections are okay, substitute known-good climate control unit and recheck. If symptom does not exist after substituting known-good climate control unit, replace original climate control unit.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.