Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Component Specifications, Transmission Control Module (TCM)
GEAR SHIFT SOLENOIDS S1, S2
| Component | Note | Resistance (Ω) |
| Gear shift solenoid S1, S2 | Resistance between the solenoid pins and the solenoid casing/transmission housing. | +20 °C = 11-15 Ω |
See the diagram for other values. When measuring at temperatures other than +20 °C, a test measurement must be taken at +20 °C. This is to establish if the resistance is correct or not.
LINEAR PRESSURE SOLENOIDS SLT, LOCK-UP SOLENOID SLU, AND ELECTROMAGNETIC OIL PUMP EMOP
| Component | Note | Resistance (Ω) |
| Linear pressure solenoid SLT Lock-up solenoid SLU Electromagnetic oil pump EMOP |
Resistance between solenoid pins. | +20 °C = 5.0 - 5.6 Ω |
See the diagram for other values. When measuring at temperatures other than +20 °C, a test measurement must be taken at +20 °C. This is to establish if the resistance is correct or not.
LINEAR PRESSURE SOLENOIDS SL1, SL2, SL3, SL4, SL5
| Component | Note | Resistance (Ω) |
| Linear pressure solenoids SL1, SL2, SL3, SL4, SL5 | Resistance between solenoid pins. | +20 °C= 5.0 - 5.6 Ω |
See the diagram for other values. When measuring at temperatures other than +20 °C, a test measurement must be taken at +20 °C. This is to establish if the resistance is correct or not.
OIL TEMPERATURE SENSOR
| Component | Note | Resistance (Ω) |
| Oil temperature sensor | Resistance between the temperature sensor terminals. | -30 °C = 3590 - 5210 Ω |
| +10 °C = 5587 - 7303 Ω | ||
| +25 °C≈ 3500 Ω | ||
| +40 °C = 1800 - 2200 Ω | ||
| +60 °C = 900 - 1100 Ω | ||
| +80 °C = 450 - 550 Ω | ||
| +110 °C = 223 - 71 Ω |
Resistance decreases with increasing temperature.
The measurement test should be performed at both temperatures to ensure that the resistance is correct.
SOLENOID P-POSITION LOCKOUT
| Component | Note | Resistance (Ω) |
| Solenoid p-position lockout | Resistance between the solenoid's connections | +20°C = 35-37 Ω |
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.