DTC Volvo Code Description
B108F PDM-B108F23 Cabin Lock/Unlock Switch. General Signal Failures. Signal stuck low
B10EC PDM-B10EC11 Passenger door double locking motor. General Electrical Failures. Circuit short to ground
B10EC PDM-B10EC15 Passenger door double locking motor. General Electrical Failures. Circuit short to battery or open
B10EE PDM-B10EE11 Rear door passenger side double locking motor. General Electrical Failures. Circuit short to ground
B10EE PDM-B10EE15 Rear door passenger side double locking motor. General Electrical Failures. Circuit short to battery or open
B1109 PDM-B110911 Passenger door central locking motor. General Electrical Failures. Circuit short to ground
B1109 PDM-B110915 Passenger door central locking motor. General Electrical Failures. Circuit short to battery or open
B110B PDM-B110B11 Rear door passenger side central locking motor. General Electrical Failures. Circuit short to ground
B110B PDM-B110B15 Rear door passenger side central locking motor. General Electrical Failures. Circuit short to battery or open
B110D PDM-B110D11 Rear door passenger side power child locking motor. General Electrical Failures. Circuit short to ground
B110D PDM-B110D15 Rear door passenger side power child locking motor. General Electrical Failures. Circuit short to battery or open
B1163 PDM-B116311 Left mirror heater output. General Electrical Failures. Circuit short to ground
B1163 PDM-B116315 Left mirror heater output. General Electrical Failures. Circuit short to battery or open
B1164 PDM-B116411 Right mirror heater output. General Electrical Failures. Circuit short to ground
B1164 PDM-B116415 Right mirror heater output. General Electrical Failures. Circuit short to battery or open
B1165 PDM-B116511 Left front puddle lamp output. General Electrical Failures. Circuit short to ground
B1165 PDM-B116515 Left front puddle lamp output. General Electrical Failures. Circuit short to battery or open
B1166 PDM-B116611 Right front puddle lamp output. General Electrical Failures. Circuit short to ground
B1166 PDM-B116615 Left front puddle lamp output. General Electrical Failures. Circuit short to battery or open
B117C PDM-B117C07 Rear power window up. General Failure Information. Mechanical Failures
B117C PDM-B117C72 Rear power window up. Mechanical Failures. Actuator stuck open
B117C PDM-B117C73 Rear power window up. Mechanical Failures. Actuator stuck closed
B117D PDM-B117D72 Rear power window down. Mechanical Failures. Actuator stuck open
B117D PDM-B117D73 Rear power window down. Mechanical Failures. Actuator stuck closed
B117E PDM-B117E07 Front power window up. General Failure Information. Mechanical Failures
B117E PDM-B117E72 Front power window up. Mechanical Failures. Actuator stuck open
B117E PDM-B117E73 Front power window up. Mechanical Failures. Actuator stuck closed
B117F PDM-B117F72 Front power window down. Mechanical Failures. Actuator stuck open
B117F PDM-B117F73 Front power window down. Mechanical Failures. Actuator stuck closed
B1189 PDM-B118929 Front Window Position Sensor. General Signal Failures. Signal signal invalid
B118A PDM-B118A29 Rear Window Position Sensor. General Signal Failures. Signal signal invalid
B118C PDM-B118C04 Left blind spot warning indicator. General Failure Information. System Internal Failures
B118C PDM-B118C11 Left blind spot warning indicator. General Electrical Failures. Circuit short to ground
B118C PDM-B118C12 Left blind spot warning indicator. General Electrical Failures. Circuit short to battery
B118C PDM-B118C13 Left blind spot warning indicator. General Electrical Failures. Circuit open
B118D PDM-B118D04 Invalid data received from "Door Control Module A". General Failure Information. System Internal Failures
B118D PDM-B118D11 Right blind spot warning indicator. General Electrical Failures. Circuit short to ground
B118D PDM-B118D12 Right blind spot warning indicator. General Electrical Failures. Circuit short to battery
B118D PDM-B118D13 Right blind spot warning indicator. General Electrical Failures. Circuit open
B11B9 PDM-B11B911 Passenger Blind Spot Warning Indicator Supply. General Electrical Failures. Circuit short to ground
B11B9 PDM-B11B915 Passenger Blind Spot Warning Indicator Supply. General Electrical Failures. Circuit short to battery or open
B11F7 PDM-B11F711 Passenger Folding Mirror Motor. General Electrical Failures. Circuit short to ground
B11F7 PDM-B11F715 Passenger Folding Mirror Motor. General Electrical Failures. Circuit short to battery or open
B1A95 PDM-B1A9511 Passenger Mirror. General Electrical Failures. Circuit short to ground
B1A95 PDM-B1A9515 Passenger Mirror. General Electrical Failures. Circuit short to battery or open
B1A98 PDM-B1A9883 LIN Bus circuit #1. Bus Signal/Message Failures. Value of signal protection calculation incorrect
B1A98 PDM-B1A9886 LIN Bus circuit #1. Bus Signal/Message Failures. Signal invalid
B1A98 PDM-B1A9887 LIN Bus circuit #1. Bus Signal/Message Failures. Missing message
B1B70 PDM-B1B7083 LIN Bus Circuit #2. Bus Signal/Message Failures. Value of signal protection calculation incorrect
B1B70 PDM-B1B7086 LIN Bus Circuit #2. Bus Signal/Message Failures. Signal invalid
B1B70 PDM-B1B7087 LIN Bus Circuit #2. Bus Signal/Message Failures. Missing message
B1C11 PDM-B1C1111 Passenger Left/Right Mirror Motor Circuit. General Electrical Failures. Circuit short to ground
B1C12 PDM-B1C1211 Driver Up/Down Mirror Motor Circuit. General Electrical Failures. Circuit short to ground
B1C15 PDM-B1C1511 Passenger Up/Down Mirror Motor Feedback Circuit. General Electrical Failures. Circuit short to ground
B1C15 PDM-B1C1515 Passenger Up/Down Mirror Motor Feedback Circuit. General Electrical Failures. Circuit short to battery or open
B1C16 PDM-B1C1611 Passenger Left/Right Mirror Motor Feedback Circuit. General Electrical Failures. Circuit short to ground
B1C16 PDM-B1C1615 Passenger Left/Right Mirror Motor Feedback Circuit. General Electrical Failures. Circuit short to battery or open
B1C39 PDM-B1C3929 Key Lock Switch. General Signal Failures. Signal signal invalid
B1D06 PDM-B1D0611 Left Turn Indicator. General Electrical Failures. Circuit short to ground
B1D06 PDM-B1D0615 Left Turn Indicator. General Electrical Failures. Circuit short to battery or open
B1D07 PDM-B1D0711 Right Turn Indicator. General Electrical Failures. Circuit short to ground
B1D07 PDM-B1D0715 Right Turn Indicator. General Electrical Failures. Circuit short to battery or open
C1B14 PDM-C1B1411 Sensor Supply Voltage A. General Electrical Failures. Circuit short to ground
C1B14 PDM-C1B1415 Sensor Supply Voltage A. General Electrical Failures. Circuit short to battery or open
C1B15 PDM-C1B1511 Sensor Supply Voltage B. General Electrical Failures. Circuit short to ground
C1B15 PDM-C1B1515 Sensor Supply Voltage B. General Electrical Failures. Circuit short to battery or open
U0140 PDM-U014000 Lost Communication With Central electronic module. General Failure Information. No sub type information
U0208 PDM-U020800 Lost Communication With Power seat module. General Failure Information. No sub type information
U2002 PDM-U200224 Switch. General Signal Failures. Signal stuck high
U2004 PDM-U200424 Auxilliary Switch Pack. General Signal Failures. Signal stuck high
U2010 PDM-U201011 Switch Illumination. General Electrical Failures. Circuit short to ground
U2012 PDM-U201208 Car Configuration Parameter(s). General Failure Information. Bus Signal/Message Failures
U3003 PDM-U300362 Battery Voltage. Algorithm Based Failures. Signal compare failure
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.