2002 Volvo S80 BaseFACTORY OEM SERVICE PROCEDURE

Shut-Off Valve (Bi-Fuel)

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2009 Volvo S60, 2008 Volvo S60, 2007 Volvo S60, 2006 Volvo S60, and 2005 Volvo S60. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Identifying Shut-Off Valve Input And Output Signals (Bi-Fuel)
GLL102916Courtesy of VOLVO CARS OF NORTH AMERICA.

The rear electronic module (REM) (4/58) controls the shut-off valves, (8/88-90) (CNG) and (8/76) (LPG), via a directly connected relay (2/140) which supplies the valves with power when they should be open.

The rear electronic module (REM) receives information via the control area network (CAN) from the engine control module (ECM) (4/46) indicating that the car should run on gas/LPG. The rear electronic module (REM) also receives information via the control area network (CAN) from the central electronic module (CEM) (4/56) indicating the position of the ignition and data about collision status. When the ignition is on and no collision has been registered, the rear electronic module (REM) activates the relay, which supplies the valves with power.

The rear electronic module (REM) deactivates the relay in the following cases:

  • there is a signal from the engine control module (ECM) indicating that gasoline operation has been selected
  • ignition off
  • the collision status changes
  • there is a fault in the communication on the controller area network (CAN).

The relay can be activated via a diagnostic command to, for example, allow the tank to be drained. Activation is carried out in appropriate diagnostics tool via the vehicle communication socket. See function group 3, Rear Electronic Module (REM).

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.