1983 Volvo 244 GLT, AutomaticFACTORY OEM SERVICE PROCEDURE

Injectors Quick Check

Start engine. Listen to each injector separately with a screwdriver. Obvious clicking sounds will be heard if valve functions. If clicking sound not heard: measure injector resistance. Resistance should be approximately 16 ohms. If clicking sound is heard, but engine runs thoroughly, remove injector connector. If engine speed decreases injector is OK.

Injectors are removed/installed complete w/injection manifold.

WARNING: Injection manifold is filled w/fuel. Use extreme caution when removing injectors from injection manifold.

Check injector O-rings and replace if required. Lubricate O-rings w/vaseline.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.