Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2023 VinFast VF9 EcoFACTORY OEM SERVICE PROCEDURE
Forward Facing Radar DTCS
FORWARD FACING RADAR DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION
| DTC | Description |
|---|---|
| U1117-81 | Lost Communication With IDB Module - Missing Message |
| U1118-81 | Lost Communication With IDB Module - Missing Message |
| U1120-81 | Lost Communication With IDB Module - Missing Message |
| U1121-81 | Lost Communication With IDB Module - Missing Message |
| U1122-81 | Lost Communication With IDB Module - Missing Message |
| U1124-81 | Lost Communication With SAS Module - Missing Message |
| U1125-81 | Lost Communication With YSS Module - Missing Message |
| U1126-81 | Lost Communication With YSS Module - Missing Message |
| U1127-81 | Lost Communication With YSS Module - Missing Message |
| U1132-81 | Lost Communication With MHU Module - Missing Message |
| U1133-81 | Lost Communication With MHU Module - Missing Message |
| U1141-81 | Lost Communication With BCM Module - Missing Message |
| U1142-81 | Lost Communication With BCM Module - Missing Message |
| U1143-81 | Lost Communication With BCM Module - Missing Message |
| U1146-81 | Lost Communication With BCM Module - Missing Message |
| U1148-81 | Lost Communication With XGW Module - Missing Message |
| U1161-81 | Lost Communication With IDB Module - Missing Message |
| U1162-81 | Lost Communication With IDB Module - Missing Message |
| U1164-81 | Lost Communication With VCU Module - Missing Message |
| U1115-83 | Received Message From IDB Module With An Incorrect Checksum - Invalid Checksum |
| U1117-83 | Received Message From IDB Module With An Incorrect Checksum - Invalid Checksum |
| U1118-83 | Received Message From SAS Module With An Incorrect Checksum - Invalid Checksum |
| U1119-83 | Received Message From YSS Module With An Incorrect Checksum - Invalid Checksum |
| U1120-83 | Received Message From YSS Module With An Incorrect Checksum - Invalid Checksum |
| U1121-83 | Received Message From YSS Module With An Incorrect Checksum - Invalid Checksum |
| U1140-83 | Received Message From BCM Module With An Incorrect Checksum - Invalid Checksum |
| U1142-83 | Received Message From BCM Module With An Incorrect Checksum - Invalid Checksum |
| U1143-83 | Received Message From XGW Module With An Incorrect Checksum - Invalid Checksum |
| U1115-82 | Received Message From IDB Module With An Incorrect Alive Counter - Invalid Alive Counter |
| U1117-82 | Received Message From IDB Module With An Incorrect Alive Counter - Invalid Alive Counter |
| U1118-82 | Received Message From SAS Module With An Incorrect Alive Counter - Invalid Alive Counter |
| U1119-82 | Received Message From YSS Module With An Incorrect Alive Counter - Invalid Alive Counter |
| U1120-82 | Received Message From YSS Module With An Incorrect Alive Counter - Invalid Alive Counter |
| U1121-82 | Received Message From YSS Module With An Incorrect Alive Counter - Invalid Alive Counter |
| U1140-82 | Received Message From BCM Module With An Incorrect Alive Counter - Invalid Alive Counter |
| U1142-82 | Received Message From BCM Module With An Incorrect Alive Counter - Invalid Alive Counter |
| U1143-82 | Received Message From XGW Module With An Incorrect Alive Counter - Invalid Alive Counter |
| U1119-89 | Received Message From IDB Module With An Invalid Value - Invalid Value |
| U1120-89 | Received Message From IDB Module With An Invalid Value - Invalid Value |
| U1127-89 | Received Message From SAS Module With An Invalid Value - Invalid Value |
| U1128-89 | Received Message From YSS Module With An Invalid Value - Invalid Value |
| U1136-89 | Received Message From YSS Module With An Invalid Value - Invalid Value |
| U1137-89 | Received Message From YSS Module With An Invalid Value - Invalid Value |
| U1138-89 | Received Message From YSS Module With An Invalid Value - Invalid Value |
| U1139-89 | Received Message From YSS Module With An Invalid Value - Invalid Value |
| U1140-89 | Received Message From YSS Module With An Invalid Value - Invalid Value |
| U1141-89 | Received Message From BCM Module With An Invalid Value - Invalid Value |
| U1160-89 | Received Message From BCM Module With An Invalid Value - Invalid Value |
| U1161-89 | Received Message From BCM Module With An Invalid Value - Invalid Value |
| U1169-89 | Received Message From BCM Module With An Invalid Value - Invalid Value |
| U1177-89 | Received Message From SCM Module With An Invalid Value - Invalid Value |
| U1185-89 | Received Message From IDB Module With An Invalid Value - Invalid Value |
| U1186-89 | Received Message From IDB Module With An Invalid Value - Invalid Value |
| U1188-89 | Received Message From VCU Module With An Invalid Value - Invalid Value |
| U1189-89 | Received Message From VCU Module With An Invalid Value - Invalid Value |
| U1190-89 | Received Message From VCU Module With An Invalid Value - Invalid Value |
| U0073-88 | Detection Of The Fault In Case Of The Vehicle CAN Is In BUS OFF State - Bus OFF |
| U1012-88 | Detection Of The Fault In Case Of The Private CAN Is In BUS OFF State - Bus OFF |
| C150C-1C | System Reports Fault When Battery Voltages Reach Out of Range (Voltage 8 V Or Voltage > 16V) - Battery |
| B1C7B-00 | System Reports Fault When Battery Voltages Reach Out Of Range (Voltage 6V) - Internal General Failure |
| B1C62-00 | Monitoring Of Initial Alignment Status. Fault Is Set If No Sensor Alignment Was Yet Performed - Internal General Failure |
| B1C63-00 | Monitoring Of The Azimuth/Elevation Angles Estimated During Initial Alignment And Online |
| B1C64-00 | Monitoring If FOV Is Free Of Impairment - Internal General Failure |
| B1C65-00 | Monitoring If FOV Is Free Of Impairment - Internal General Failure |
| U1371-13 | Monitor Whether The Message 151 Has Been Sent Out - Mute |
| B1C77-00 | Time Stamp Received From The Master Clock Is Invalid (CRC Error) - Internal General Failure |
| B1C78-00 | Time Stamp Received From the Master Is Deviated From The Time Slave By The Acceptable Threshold Value - Internal General Failure |
| B1C68-00 | Monitoring The Amount Of Jamming - Internal General Failure |
| B1C71-00 | Monitoring Of Sudden Changes In The Alignment Which Are Not Explainable By Normal Driving Scenarios And Chassis Movement - Internal General Failure |
| C1500-54 | Radar Calibration Is Not Done - Calibration Failure |
| C1501-54 | Radar Calibration Version Is Mismatch - Calibration Failure |
| C1504-96 | Internal Fault - Internal Failure |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.
