Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2023 VinFast VF9 EcoFACTORY OEM SERVICE PROCEDURE
Lighting System DTCS
LIGHTING SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION
| DTC | Description |
|---|---|
| U0447-81 | Invalid Data Received From XGW-Invalid Serial Data Received |
| U0447-82 | Invalid Data Received From XGW - Alive/Sequence Counter Incorrect/Not Updated |
| U0447-83 | Invalid Data Received From XGW - Value Of Signal Protection Calculation Incorrect |
| U0146-87 | Lost Communication With XGW - Missing Message |
| U0422-81 | Invalid Data Received From BCM-Invalid Serial Data Received |
| B2200-01 | Partial LEDs Of Matrix High Beam Fault - General Electric Failure |
| B2200-11 | Matrix High Beam Fault (ECE)/BI-High Beam (SAE) - Circuit Short To GND |
| B2200-13 | Matrix High Beam Fault (ECE)/BI-High Beam (SAE) - Circuit Open |
| B2201-01 | Partial LEDs Of Matrix Low Beam Fault - General Electric Failure |
| B2201-11 | Matrix Low Beam Fault - Circuit Short To GND |
| B2201-13 | Matrix Low Beam Fault (ECE)/BI-Low Beam (SAE) - Circuit Open |
| B2202-11 | Auxiliary High Beam Fault (ECE Only) - Circuit Short To GND |
| B2202-13 | Auxiliary High Beam Fault (ECE Only) - Circuit Open |
| B2203-4A | LDM and Lamp Mismatch - Incorrect Component Installed |
| B2203-4B | Lamp Module Temperature High - Over Temperature |
| B2205-11 | Auxiliary Low Beam Fault - Circuit Short To GND |
| B2205-13 | Auxiliary Low Beam Fault - Circuit Open |
| B2206-01 | Partial LEDs Of Turn Indicator Fault - General Electric Failure |
| B2206-11 | Turn Indicator Circuit Fault - Circuit Short To GND |
| B2206-13 | Turn Indicator Fault - Circuit Open |
| B2208-01 | Partial LEDs Of Position/Daytime Running Lamp Fault - General |
| B2208-11 | Position/Daytime Running Lamp Fault - Circuit Short To GND |
| B2208-13 | Position/Daytime Running Lamp Fault - Circuit Open |
| B220A-09 | Stepper Motor Fault - Component Failures |
| B220A-13 | Stepper Motor Fault - Circuit Open |
| B220B-11 | Front VLS Fault - Circuit Short To GND |
| B220B-15 | Front VLS Fault - Circuit Short To Battery Or Open |
| B220B-86 | Front VLS Fault - Signal Invalid |
| B220C-11 | Rear VLS Fault - Circuit Short To GND |
| B220C-15 | Rear VLS Fault - Circuit Short To Battery Or Open |
| B220C-61 | VLS Calibration Fault - Signal Calculation Failure |
| B220C-86 | Rear VLS Fault - Signal Invalid |
| U0274-87 | Lost Communication With LDMR - Missing Message |
| U1185-88 | Private CAN - Bus Off |
| U3000-49 | LDM Internal Fault - Internal Electronic Failure |
| U0273-87 | Lost Communication With LDML - Missing Message |
| U3002-55 | VIN Not Configured In ECU - Not Configured |
| U1174-88 | Body CAN - Bus Off |
| U1100-17 | Power Supply - Circuit Voltage Above Threshold |
| U1101-16 | Power Supply - Circuit Voltage Below Threshold |
| U0422-82 | Invalid Data Received From BCM - Alive/Sequence Counter Incorrect |
| U0422-83 | Invalid Data Received From BCM - Value Of Signal Protection |
| U0140-87 | Lost Communication With BCM - Missing Message |
| U3000-4B | LDM Temperature High - Over Temperature |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.