Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2017 Toyota Prius Prime AdvancedFACTORY OEM SERVICE PROCEDURE
Hybrid Control System
HYBRID CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION [09/2016 - 01/2018]
| DTC Code | Description |
|---|---|
| P056014 | System Voltage (BATT) Circuit Short to Ground or Open |
| P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure |
| P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message |
| P060694 | Hybrid/EV Powertrain Control Module Processor Unexpected Operation |
| P060A29 | Hybrid/EV Powertrain Control Module Monitoring Processor Signal Invalid |
| P060A44 | Hybrid/EV Powertrain Control Module Monitoring Processor Data Memory Failure |
| P060A45 | Hybrid/EV Powertrain Control Module Monitoring Processor Program Memory Failure |
| P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure |
| P060A49 | Hybrid/EV Powertrain Control Module Monitoring Processor Internal Electronic Failure |
| P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message |
| P060A94 | Hybrid/EV Powertrain Control Module Monitoring Processor Unexpected Operation |
| P060B1C | Hybrid/EV Powertrain Control Module A/D Processing Voltage Out of Range |
| P060B49 | Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure |
| P060B71 | Hybrid/EV Powertrain Control Module A/D Processing Actuator Stuck |
| P062F44 | Hybrid/EV Powertrain Control Module EEPROM Data Memory Failure |
| P06881F | ECM/PCM Power Relay Sense Circuit Intermittent |
| P082112 | Gear Lever X Position Sensor 1 Circuit Short to Auxiliary Battery |
| P082114 | Gear Lever X Position Sensor 1 Circuit Short to Ground or Open |
| P082211 | Gear Lever Y Position Sensor 1 Circuit Short to Ground |
| P082215 | Gear Lever Y Position Sensor 1 Circuit Short to Auxiliary Battery or Open |
| P085011 | Park/Neutral Switch Circuit Short to Ground |
| P085015 | Park/Neutral Switch Circuit Short to Auxiliary Battery or Open |
| P0A0A13 | High Voltage System Interlock Circuit Open |
| P0A0A92 | High Voltage System Interlock Performance or Incorrect Operation |
| P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure |
| P0A1B94 | Drive Motor "A" Control Module Unexpected Operation |
| P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
| P0A2A11 | Drive Motor "A" Temperature Sensor Circuit Short to Ground |
| P0A2A15 | Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P0A2A1C | Drive Motor "A" Temperature Sensor Voltage Out of Range |
| P0A2A1F | Drive Motor "A" Temperature Sensor Circuit Intermittent |
| P0A3611 | Generator Temperature Sensor Circuit Short to Ground |
| P0A3615 | Generator Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P0A361C | Generator Temperature Sensor Voltage Out of Range |
| P0A361F | Generator Temperature Sensor Circuit Intermittent |
| P0A9300 | Inverter "A" Cooling System Performance |
| P0AA000 | Hybrid/EV Battery Positive Contactor Circuit Stuck Closed |
| P0AA073 | Hybrid/EV Battery Positive and Negative Contactor Actuator Stuck Closed |
| P0AA373 | Hybrid/EV Battery Negative Contactor Actuator Stuck Closed |
| P0AA649 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure |
| P0AA716 | Hybrid/EV Battery Voltage Isolation Sensor Circuit Voltage Below Threshold |
| P0AA717 | Hybrid/EV Battery Voltage Isolation Sensor Circuit Voltage Above Threshold |
| P0AA749 | Hybrid/EV Battery Voltage Isolation Sensor Circuit Internal Electronic Failure |
| P0ABF00 | Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance |
| P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
| P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open |
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground |
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open |
| P0AE173 | Hybrid/EV Battery Precharge Contactor Actuator Stuck Closed |
| P0AE411 | Hybrid/EV Battery Precharge Contactor Circuit Short to Ground |
| P0AE415 | Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open |
| P0B231C | Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range |
| P0C7396 | Motor Electronics Coolant Pump "A" Component Internal Failure |
| P0C7600 | Hybrid/EV Battery System Discharge Time Too Long |
| P0D0700 | Hybrid/EV Battery Charging System Positive Contactor Stuck Closed |
| P0D0773 | Hybrid/EV Battery Charging System Positive/Negative Contactor Actuator Stuck Closed |
| P0D0E73 | Hybrid/EV Battery Charging System Negative Contactor Control Actuator Stuck Closed |
| P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range |
| P0D4C1C | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Voltage Out of Range |
| P0D5E00 | Hybrid/EV Battery Charger Hybrid/EV System Discharge Time Too Long |
| P0E311C | Boosting Converter Voltage Sensor "A" Voltage Out of Range |
| P0E619E | Hybrid/EV Battery Charger Enable Circuit Stuck On |
| P0E6A73 | Hybrid/EV Battery Charging System Precharge Contactor Control Actuator Stuck Closed |
| P160600 | Collision detected or Collision Sensor Connection (Open) |
| P160604 | Collision detected or Collision Sensor Connection (Open) System Internal Failure |
| P181B62 | Gear Lever Position Sensor Signal Compare Failure |
| P182112 | Gear Lever X Position Sensor 2 Circuit Short to Auxiliary Battery |
| P182114 | Gear Lever X Position Sensor 2 Circuit Short to Ground or Open |
| P182211 | Gear Lever Y Position Sensor 2 Circuit Short to Ground |
| P182215 | Gear Lever Y Position Sensor 2 Circuit Short to Auxiliary Battery or Open |
| P1AC413 | Hybrid/EV Battery Stack 1 Current Interrupt Device Circuit Open |
| P1C2979 | One Way Clutch Mechanical Linkage Failure |
| P1C2D62 | Hybrid/EV Battery "A" Voltage Sensor/Boosting Converter Voltage Sensor "A" Signal Compare Failure |
| P1C6A9F | Motor Shutdown Stuck Off |
| P1C6C9F | Generator Shutdown Stuck Off |
| P1C7779 | Engine Failed to Start Mechanical Linkage Failure |
| P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
| P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure |
| P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure |
| P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
| P1C8149 | High Voltage Power Resource Circuit Consumption Circuit Short |
| P1C8249 | High Voltage Power Resource Circuit Over Loading |
| P1C8349 | High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction |
| P1C8449 | High Voltage Power Resource Circuit Short during Ready ON |
| P1C8679 | Transmission (Input) Mechanical Linkage Failure |
| P1C8779 | Generator Mechanical Linkage Failure |
| P1C8879 | Planetary Gear Mechanical Linkage Failure |
| P1C9E9F | Hybrid/EV System Reset Stuck Off |
| P1CD800 | Hybrid/EV Powertrain Control Module Processor or Monitoring Processor Charging Permission Signal Internal Failure |
| P1CD900 | Hybrid/EV Powertrain Control Module Processor and Monitoring Processor Charging Permission Signal Stuck On |
| P1CDA00 | Hybrid/EV Powertrain Control Module Processor and Monitoring Processor Charging Permission Signal Stuck Off |
| P1CE213 | PCU Interlock Circuit Open |
| P1CE292 | PCU Interlock Performance or Incorrect Operation |
| P1CE31C | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Voltage Out of Range |
| P1CE349 | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Internal Electronic Failure |
| P1CE371 | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Actuator Stuck |
| P1CF749 | Hybrid/EV Battery Voltage System Isolation (Charger Area) Internal Electronic Failure |
| P1CFA12 | IGB Signal Circuit Short to Auxiliary Battery |
| P212012 | Throttle/Pedal Position Sensor/Switch "D" Circuit Short to Auxiliary Battery |
| P212014 | Throttle/Pedal Position Sensor/Switch "D" Circuit Short to Ground or Open |
| P21201C | Throttle/Pedal Position Sensor/Switch "D" Voltage Out of Range |
| P21201F | Throttle/Pedal Position Sensor/Switch "D" Circuit Intermittent |
| P212512 | Throttle/Pedal Position Sensor/Switch "E" Circuit Short to Auxiliary Battery |
| P212514 | Throttle/Pedal Position Sensor/Switch "E" Circuit Short to Ground or Open |
| P21251C | Throttle/Pedal Position Sensor/Switch "E" Voltage Out of Range |
| P21251F | Throttle/Pedal Position Sensor/Switch "E" Circuit Intermittent |
| P213800 | Throttle/Pedal Position Sensor/Switch "D"/" E" Voltage Correlation |
| P21382B | Throttle/Pedal Position Sensor/Switch "D"/"E" Signal Cross Coupled |
| P253012 | IG2 Signal Circuit Short to Auxiliary Battery |
| P260031 | Motor/Generator Coolant Pump "A" Control Circuit No Signal |
| P260096 | Motor/Generator Coolant Pump "A" Control Circuit Component Internal Failure |
| P26009E | Motor/Generator Coolant Pump "A" Control Circuit Stuck On |
| P272C81 | Park Pawl Motor Invalid Serial Data Received |
| P274A11 | Transmission Fluid Temperature Sensor "C" Circuit Short to Ground |
| P274A15 | Transmission Fluid Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open |
| P274A1C | Transmission Fluid Temperature Sensor "C" Voltage Out of Range |
| P274A1F | Transmission Fluid Temperature Sensor "C" Circuit Intermittent |
| P300449 | High Voltage Power Resource Circuit Short during Pre-Charge |
| P308F49 | High Voltage Charging Circuit Short during Pre-Charge |
| P309F49 | High Voltage Charging Circuit Consumption Circuit Short |
| P310711 | Lost Communication with Airbag System Control Module Circuit Short to Ground |
| P310715 | Lost Communication with Airbag System Control Module Circuit Short to Auxiliary Battery or Open |
| P310764 | Lost Communication with Airbag System Control Module Signal Plausibility Failure |
| P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message |
| P314779 | Transmission (Shaft) Mechanical Linkage Failure |
| P314A31 | Motor Electronics Coolant Pump "A" No Signal |
| P31B300 | Hybrid/EV Battery Voltage High |
| P320F00 | AC Charging Overpower |
| P321D17 | Charger Circuit Voltage Above Threshold |
| P321E9F | Motor/Generator Shutdown Signal Stuck Off |
| P33B99F | Motor/Generator Shutdown Signal (Hybrid/EV Side) Stuck Off |
| P33BF9F | Motor/Generator Shutdown Signal (MG Side) Stuck Off |
| P33CF49 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure Abnormal Area Detection Failure |
| U010087 | Lost Communication with ECM/PCM "A" Missing Message |
| U011087 | Lost Communication with Drive Motor Control Module "A" Missing Message |
| U011187 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message |
| U012287 | Lost Communication with Vehicle Dynamics Control Module Missing Message |
| U012987 | Lost Communication with Brake System Control Module Missing Message |
| U014000 | Lost Communication with Body Control Module (Sub) Missing Message |
| U014087 | Lost Communication with Body Control Module Missing Message |
| U015187 | Lost Communication with Restraints Control Module Missing Message |
| U016487 | Lost Communication with HVAC Control Module Missing Message |
| U019B87 | Lost Communication with Hybrid/EV Battery Charger Control Module Missing Message |
| U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message |
| U042481 | HVAC Control Module to Hybrid Powertrain Control Module Invalid Serial Data Received |
| U110487 | Lost Communication with Driving Support ECU Missing Message |
| U110787 | Lost Communication with Power Management Module Missing Message |
| U117087 | Lost Communication with Brake System Control Module (Secondary CAN Line) Missing Message |
| U117587 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" (Powertrain Bus) Missing Message |
HYBRID CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION [01/2018 - 12/2018]
| DTC Code | Description |
|---|---|
| P056014 | System Voltage (BATT) Circuit Short to Ground or Open |
| P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure |
| P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message |
| P060694 | Hybrid/EV Powertrain Control Module Processor Unexpected Operation |
| P060A29 | Hybrid/EV Powertrain Control Module Monitoring Processor Signal Invalid |
| P060A44 | Hybrid/EV Powertrain Control Module Monitoring Processor Data Memory Failure |
| P060A45 | Hybrid/EV Powertrain Control Module Monitoring Processor Program Memory Failure |
| P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure |
| P060A49 | Hybrid/EV Powertrain Control Module Monitoring Processor Internal Electronic Failure |
| P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message |
| P060A94 | Hybrid/EV Powertrain Control Module Monitoring Processor Unexpected Operation |
| P060B1C | Hybrid/EV Powertrain Control Module A/D Processing Voltage Out of Range |
| P060B49 | Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure |
| P060B71 | Hybrid/EV Powertrain Control Module A/D Processing Actuator Stuck |
| P062F44 | Hybrid/EV Powertrain Control Module EEPROM Data Memory Failure |
| P06881F | ECM/PCM Power Relay Sense Circuit Intermittent |
| P085011 | Park/Neutral Switch Circuit Short to Ground |
| P085015 | Park/Neutral Switch Circuit Short to Auxiliary Battery or Open |
| P08A662 | Gear Lever Position Sensor Signal Compare Failure |
| P0A0A13 | High Voltage System Interlock Circuit Open |
| P0A0A92 | High Voltage System Interlock Performance or Incorrect Operation |
| P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure |
| P0A1B94 | Drive Motor "A" Control Module Unexpected Operation |
| P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
| P0A2A11 | Drive Motor "A" Temperature Sensor Circuit Short to Ground |
| P0A2A15 | Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P0A2A1C | Drive Motor "A" Temperature Sensor Voltage Out of Range |
| P0A2A1F | Drive Motor "A" Temperature Sensor Circuit Intermittent |
| P0A3611 | Generator Temperature Sensor Circuit Short to Ground |
| P0A3615 | Generator Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P0A361C | Generator Temperature Sensor Voltage Out of Range |
| P0A361F | Generator Temperature Sensor Circuit Intermittent |
| P0A9300 | Inverter "A" Cooling System Performance |
| P0AA000 | Hybrid/EV Battery Positive Contactor Circuit Stuck Closed |
| P0AA073 | Hybrid/EV Battery Positive and Negative Contactor Actuator Stuck Closed |
| P0AA373 | Hybrid/EV Battery Negative Contactor Actuator Stuck Closed |
| P0AA649 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure |
| P0AA716 | Hybrid/EV Battery Voltage Isolation Sensor Circuit Voltage Below Threshold |
| P0AA717 | Hybrid/EV Battery Voltage Isolation Sensor Circuit Voltage Above Threshold |
| P0AA749 | Hybrid/EV Battery Voltage Isolation Sensor Circuit Internal Electronic Failure |
| P0ABF00 | Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance |
| P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
| P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open |
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground |
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open |
| P0AE173 | Hybrid/EV Battery Precharge Contactor Actuator Stuck Closed |
| P0AE411 | Hybrid/EV Battery Precharge Contactor Circuit Short to Ground |
| P0AE415 | Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open |
| P0B231C | Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range |
| P0C7396 | Motor Electronics Coolant Pump "A" Component Internal Failure |
| P0C7600 | Hybrid/EV Battery System Discharge Time Too Long |
| P0D0700 | Hybrid/EV Battery Charging System Positive Contactor Stuck Closed |
| P0D0773 | Hybrid/EV Battery Charging System Positive/Negative Contactor Actuator Stuck Closed |
| P0D0E73 | Hybrid/EV Battery Charging System Negative Contactor Control Actuator Stuck Closed |
| P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range |
| P0D4C1C | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Voltage Out of Range |
| P0D5E00 | Hybrid/EV Battery Charger Hybrid/EV System Discharge Time Too Long |
| P0E311C | Boosting Converter Voltage Sensor "A" Voltage Out of Range |
| P0E619E | Hybrid/EV Battery Charger Enable Circuit Stuck On |
| P0E6A73 | Hybrid/EV Battery Charging System Precharge Contactor Control Actuator Stuck Closed |
| P160600 | Collision detected or Collision Sensor Connection (Open) |
| P160604 | Collision detected or Collision Sensor Connection (Open) System Internal Failure |
| P183411 | Gear Lever Y Position Sensor 1 Circuit Short to Ground |
| P183415 | Gear Lever Y Position Sensor 1 Circuit Short to Auxiliary Battery or Open |
| P183A11 | Gear Lever Y Position Sensor 2 Circuit Short to Ground |
| P183A15 | Gear Lever Y Position Sensor 2 Circuit Short to Auxiliary Battery or Open |
| P183F12 | Gear Lever X Position Sensor 1 Circuit Short to Auxiliary Battery |
| P183F14 | Gear Lever X Position Sensor 1 Circuit Short to Ground or Open |
| P184512 | Gear Lever X Position Sensor 2 Circuit Short to Auxiliary Battery |
| P184514 | Gear Lever X Position Sensor 2 Circuit Short to Ground or Open |
| P1AC413 | Hybrid/EV Battery Stack 1 Current Interrupt Device Circuit Open |
| P1C2979 | One Way Clutch Mechanical Linkage Failure |
| P1C2D62 | Hybrid/EV Battery "A" Voltage Sensor/Boosting Converter Voltage Sensor "A" Signal Compare Failure |
| P1C6A9F | Motor Shutdown Stuck Off |
| P1C6C9F | Generator Shutdown Stuck Off |
| P1C7779 | Engine Failed to Start Mechanical Linkage Failure |
| P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
| P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure |
| P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure |
| P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
| P1C8149 | High Voltage Power Resource Circuit Consumption Circuit Short |
| P1C8249 | High Voltage Power Resource Circuit Over Loading |
| P1C8349 | High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction |
| P1C8449 | High Voltage Power Resource Circuit Short during Ready ON |
| P1C8679 | Transmission (Input) Mechanical Linkage Failure |
| P1C8779 | Generator Mechanical Linkage Failure |
| P1C8879 | Planetary Gear Mechanical Linkage Failure |
| P1C9E9F | Hybrid/EV System Reset Stuck Off |
| P1CD800 | Hybrid/EV Powertrain Control Module Processor or Monitoring Processor Charging Permission Signal Internal Failure |
| P1CD900 | Hybrid/EV Powertrain Control Module Processor and Monitoring Processor Charging Permission Signal Stuck On |
| P1CDA00 | Hybrid/EV Powertrain Control Module Processor and Monitoring Processor Charging Permission Signal Stuck Off |
| P1CE213 | PCU Interlock Circuit Open |
| P1CE292 | PCU Interlock Performance or Incorrect Operation |
| P1CE31C | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Voltage Out of Range |
| P1CE349 | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Internal Electronic Failure |
| P1CE371 | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Actuator Stuck |
| P1CF749 | Hybrid/EV Battery Voltage System Isolation (Charger Area) Internal Electronic Failure |
| P1CFA12 | IGB Signal Circuit Short to Auxiliary Battery |
| P212012 | Throttle/Pedal Position Sensor/Switch "D" Circuit Short to Auxiliary Battery |
| P212014 | Throttle/Pedal Position Sensor/Switch "D" Circuit Short to Ground or Open |
| P21201C | Throttle/Pedal Position Sensor/Switch "D" Voltage Out of Range |
| P21201F | Throttle/Pedal Position Sensor/Switch "D" Circuit Intermittent |
| P212512 | Throttle/Pedal Position Sensor/Switch "E" Circuit Short to Auxiliary Battery |
| P212514 | Throttle/Pedal Position Sensor/Switch "E" Circuit Short to Ground or Open |
| P21251C | Throttle/Pedal Position Sensor/Switch "E" Voltage Out of Range |
| P21251F | Throttle/Pedal Position Sensor/Switch "E" Circuit Intermittent |
| P213800 | Throttle/Pedal Position Sensor/Switch "D"/" E" Voltage Correlation |
| P21382B | Throttle/Pedal Position Sensor/Switch "D"/"E" Signal Cross Coupled |
| P253012 | IG2 Signal Circuit Short to Auxiliary Battery |
| P260031 | Motor/Generator Coolant Pump "A" Control Circuit No Signal |
| P260096 | Motor/Generator Coolant Pump "A" Control Circuit Component Internal Failure |
| P26009E | Motor/Generator Coolant Pump "A" Control Circuit Stuck On |
| P272C81 | Park Pawl Motor Invalid Serial Data Received |
| P274A11 | Transmission Fluid Temperature Sensor "C" Circuit Short to Ground |
| P274A15 | Transmission Fluid Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open |
| P274A1C | Transmission Fluid Temperature Sensor "C" Voltage Out of Range |
| P274A1F | Transmission Fluid Temperature Sensor "C" Circuit Intermittent |
| P300449 | High Voltage Power Resource Circuit Short during Pre-Charge |
| P308F49 | High Voltage Charging Circuit Short during Pre-Charge |
| P309F49 | High Voltage Charging Circuit Consumption Circuit Short |
| P310711 | Lost Communication with Airbag System Control Module Circuit Short to Ground |
| P310715 | Lost Communication with Airbag System Control Module Circuit Short to Auxiliary Battery or Open |
| P310764 | Lost Communication with Airbag System Control Module Signal Plausibility Failure |
| P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message |
| P314779 | Transmission (Shaft) Mechanical Linkage Failure |
| P314A31 | Motor Electronics Coolant Pump "A" No Signal |
| P31B300 | Hybrid/EV Battery Voltage High |
| P320F00 | AC Charging Overpower |
| P321D17 | Charger Circuit Voltage Above Threshold |
| P321E9F | Motor/Generator Shutdown Signal Stuck Off |
| P33B99F | Motor/Generator Shutdown Signal (Hybrid/EV Side) Stuck Off |
| P33BF9F | Motor/Generator Shutdown Signal (MG Side) Stuck Off |
| P33CF49 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure Abnormal Area Detection Failure |
| U010087 | Lost Communication with ECM/PCM "A" Missing Message |
| U010487 | Lost Communication with Cruise Control Module Missing Message |
| U011087 | Lost Communication with Drive Motor Control Module "A" Missing Message |
| U011187 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message |
| U012287 | Lost Communication with Vehicle Dynamics Control Module Missing Message |
| U012987 | Lost Communication with Brake System Control Module Missing Message |
| U014000 | Lost Communication with Body Control Module (Sub) Missing Message |
| U014087 | Lost Communication with Body Control Module Missing Message |
| U015187 | Lost Communication with Restraints Control Module Missing Message |
| U016487 | Lost Communication with HVAC Control Module Missing Message |
| U019B87 | Lost Communication with Hybrid/EV Battery Charger Control Module Missing Message |
| U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message |
| U042481 | HVAC Control Module to Hybrid Powertrain Control Module Invalid Serial Data Received |
| U110787 | Lost Communication with Power Management Module Missing Message |
| U117087 | Lost Communication with Brake System Control Module (Secondary CAN Line) Missing Message |
| U117587 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" (Powertrain Bus) Missing Message |
HYBRID CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION [12/2018 - 05/2019]
| DTC Code | Description |
|---|---|
| P056014 | System Voltage (BATT) Circuit Short to Ground or Open |
| P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure |
| P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message |
| P060694 | Hybrid/EV Powertrain Control Module Processor Unexpected Operation |
| P060A29 | Hybrid/EV Powertrain Control Module Monitoring Processor Signal Invalid |
| P060A44 | Hybrid/EV Powertrain Control Module Monitoring Processor Data Memory Failure |
| P060A45 | Hybrid/EV Powertrain Control Module Monitoring Processor Program Memory Failure |
| P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure |
| P060A49 | Hybrid/EV Powertrain Control Module Monitoring Processor Internal Electronic Failure |
| P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message |
| P060A94 | Hybrid/EV Powertrain Control Module Monitoring Processor Unexpected Operation |
| P060B1C | Hybrid/EV Powertrain Control Module A/D Processing Voltage Out of Range |
| P060B49 | Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure |
| P060B71 | Hybrid/EV Powertrain Control Module A/D Processing Actuator Stuck |
| P062F44 | Hybrid/EV Powertrain Control Module EEPROM Data Memory Failure |
| P06881F | ECM/PCM Power Relay Sense Circuit Intermittent |
| P085011 | Park/Neutral Switch Circuit Short to Ground |
| P085015 | Park/Neutral Switch Circuit Short to Auxiliary Battery or Open |
| P08A662 | Gear Lever Position Sensor Signal Compare Failure |
| P0A0A13 | High Voltage System Interlock Circuit Open |
| P0A0A92 | High Voltage System Interlock Performance or Incorrect Operation |
| P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure |
| P0A1B94 | Drive Motor "A" Control Module Unexpected Operation |
| P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
| P0A2A11 | Drive Motor "A" Temperature Sensor Circuit Short to Ground |
| P0A2A15 | Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P0A2A1C | Drive Motor "A" Temperature Sensor Voltage Out of Range |
| P0A2A1F | Drive Motor "A" Temperature Sensor Circuit Intermittent |
| P0A3611 | Generator Temperature Sensor Circuit Short to Ground |
| P0A3615 | Generator Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P0A361C | Generator Temperature Sensor Voltage Out of Range |
| P0A361F | Generator Temperature Sensor Circuit Intermittent |
| P0A9300 | Inverter "A" Cooling System Performance |
| P0AA000 | Hybrid/EV Battery Positive Contactor Circuit Stuck Closed |
| P0AA073 | Hybrid/EV Battery Positive and Negative Contactor Actuator Stuck Closed |
| P0AA373 | Hybrid/EV Battery Negative Contactor Actuator Stuck Closed |
| P0AA649 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure |
| P0AA749 | Hybrid/EV Battery Voltage Isolation Sensor Circuit Internal Electronic Failure |
| P0ABF00 | Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance |
| P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
| P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open |
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground |
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open |
| P0AE173 | Hybrid/EV Battery Precharge Contactor Actuator Stuck Closed |
| P0AE411 | Hybrid/EV Battery Precharge Contactor Circuit Short to Ground |
| P0AE415 | Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open |
| P0B231C | Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range |
| P0C7396 | Motor Electronics Coolant Pump "A" Component Internal Failure |
| P0C7600 | Hybrid/EV Battery System Discharge Time Too Long |
| P0D0700 | Hybrid/EV Battery Charging System Positive Contactor Stuck Closed |
| P0D0773 | Hybrid/EV Battery Charging System Positive/Negative Contactor Actuator Stuck Closed |
| P0D0E73 | Hybrid/EV Battery Charging System Negative Contactor Control Actuator Stuck Closed |
| P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range |
| P0D4C1C | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Voltage Out of Range |
| P0D5C00 | Hybrid/EV Battery Charger Hybrid/EV Battery Output Power Performance |
| P0D5E00 | Hybrid/EV Battery Charger Hybrid/EV System Discharge Time Too Long |
| P0E311C | Boosting Converter Voltage Sensor "A" Voltage Out of Range |
| P0E619E | Hybrid/EV Battery Charger Enable Circuit Stuck On |
| P0E6A73 | Hybrid/EV Battery Charging System Precharge Contactor Control Actuator Stuck Closed |
| P160600 | Collision detected or Collision Sensor Connection (Open) |
| P160604 | Collision detected or Collision Sensor Connection (Open) System Internal Failure |
| P183411 | Gear Lever Y Position Sensor 1 Circuit Short to Ground |
| P183415 | Gear Lever Y Position Sensor 1 Circuit Short to Auxiliary Battery or Open |
| P183A11 | Gear Lever Y Position Sensor 2 Circuit Short to Ground |
| P183A15 | Gear Lever Y Position Sensor 2 Circuit Short to Auxiliary Battery or Open |
| P183F12 | Gear Lever X Position Sensor 1 Circuit Short to Auxiliary Battery |
| P183F14 | Gear Lever X Position Sensor 1 Circuit Short to Ground or Open |
| P184512 | Gear Lever X Position Sensor 2 Circuit Short to Auxiliary Battery |
| P184514 | Gear Lever X Position Sensor 2 Circuit Short to Ground or Open |
| P1AC413 | Hybrid/EV Battery Stack 1 Current Interrupt Device Circuit Open |
| P1C2979 | One Way Clutch Mechanical Linkage Failure |
| P1C2D62 | Hybrid/EV Battery "A" Voltage Sensor/Boosting Converter Voltage Sensor "A" Signal Compare Failure |
| P1C6A9F | Motor Shutdown Stuck Off |
| P1C6C9F | Generator Shutdown Stuck Off |
| P1C7779 | Engine Failed to Start Mechanical Linkage Failure |
| P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
| P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure |
| P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure |
| P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
| P1C8149 | High Voltage Power Resource Circuit Consumption Circuit Short |
| P1C8249 | High Voltage Power Resource Circuit Over Loading |
| P1C8349 | High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction |
| P1C8449 | High Voltage Power Resource Circuit Short during Ready ON |
| P1C8679 | Transmission (Input) Mechanical Linkage Failure |
| P1C8779 | Generator Mechanical Linkage Failure |
| P1C8879 | Planetary Gear Mechanical Linkage Failure |
| P1C9E9F | Hybrid/EV System Reset Stuck Off |
| P1CD800 | Hybrid/EV Powertrain Control Module Processor or Monitoring Processor Charging Permission Signal Internal Failure |
| P1CD900 | Hybrid/EV Powertrain Control Module Processor and Monitoring Processor Charging Permission Signal Stuck On |
| P1CDA00 | Hybrid/EV Powertrain Control Module Processor and Monitoring Processor Charging Permission Signal Stuck Off |
| P1CE213 | PCU Interlock Circuit Open |
| P1CE292 | PCU Interlock Performance or Incorrect Operation |
| P1CE31C | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Voltage Out of Range |
| P1CE349 | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Internal Electronic Failure |
| P1CE371 | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Actuator Stuck |
| P1CF749 | Hybrid/EV Battery Voltage System Isolation (Charger Area) Internal Electronic Failure |
| P1CFA12 | IGB Signal Circuit Short to Auxiliary Battery |
| P212012 | Throttle/Pedal Position Sensor/Switch "D" Circuit Short to Auxiliary Battery |
| P212014 | Throttle/Pedal Position Sensor/Switch "D" Circuit Short to Ground or Open |
| P21201C | Throttle/Pedal Position Sensor/Switch "D" Voltage Out of Range |
| P21201F | Throttle/Pedal Position Sensor/Switch "D" Circuit Intermittent |
| P212512 | Throttle/Pedal Position Sensor/Switch "E" Circuit Short to Auxiliary Battery |
| P212514 | Throttle/Pedal Position Sensor/Switch "E" Circuit Short to Ground or Open |
| P21251C | Throttle/Pedal Position Sensor/Switch "E" Voltage Out of Range |
| P21251F | Throttle/Pedal Position Sensor/Switch "E" Circuit Intermittent |
| P213800 | Throttle/Pedal Position Sensor/Switch "D"/" E" Voltage Correlation |
| P21382B | Throttle/Pedal Position Sensor/Switch "D"/"E" Signal Cross Coupled |
| P253012 | IG2 Signal Circuit Short to Auxiliary Battery |
| P260031 | Motor/Generator Coolant Pump "A" Control Circuit No Signal |
| P260096 | Motor/Generator Coolant Pump "A" Control Circuit Component Internal Failure |
| P26009E | Motor/Generator Coolant Pump "A" Control Circuit Stuck On |
| P272C81 | Park Pawl Motor Invalid Serial Data Received |
| P274A11 | Transmission Fluid Temperature Sensor "C" Circuit Short to Ground |
| P274A15 | Transmission Fluid Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open |
| P274A1C | Transmission Fluid Temperature Sensor "C" Voltage Out of Range |
| P274A1F | Transmission Fluid Temperature Sensor "C" Circuit Intermittent |
| P300449 | High Voltage Power Resource Circuit Short during Pre-Charge |
| P308F49 | High Voltage Charging Circuit Short during Pre-Charge |
| P309F49 | High Voltage Charging Circuit Consumption Circuit Short |
| P310711 | Lost Communication with Airbag System Control Module Circuit Short to Ground |
| P310715 | Lost Communication with Airbag System Control Module Circuit Short to Auxiliary Battery or Open |
| P310764 | Lost Communication with Airbag System Control Module Signal Plausibility Failure |
| P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message |
| P314779 | Transmission (Shaft) Mechanical Linkage Failure |
| P314A31 | Motor Electronics Coolant Pump "A" No Signal |
| P31B300 | Hybrid/EV Battery Voltage High |
| P320F00 | AC Charging Overpower |
| P321D17 | Charger Circuit Voltage Above Threshold |
| P321E9F | Motor/Generator Shutdown Signal Stuck Off |
| P33B99F | Motor/Generator Shutdown Signal (Hybrid/EV Side) Stuck Off |
| P33BF9F | Motor/Generator Shutdown Signal (MG Side) Stuck Off |
| P33CF49 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure Abnormal Area Detection Failure |
| U010087 | Lost Communication with ECM/PCM "A" Missing Message |
| U010487 | Lost Communication with Cruise Control Module Missing Message |
| U011087 | Lost Communication with Drive Motor Control Module "A" Missing Message |
| U011187 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message |
| U012287 | Lost Communication with Vehicle Dynamics Control Module Missing Message |
| U012987 | Lost Communication with Brake System Control Module Missing Message |
| U014000 | Lost Communication with Body Control Module (Sub) Missing Message |
| U014087 | Lost Communication with Body Control Module Missing Message |
| U015187 | Lost Communication with Restraints Control Module Missing Message |
| U016487 | Lost Communication with HVAC Control Module Missing Message |
| U019B87 | Lost Communication with Hybrid/EV Battery Charger Control Module Missing Message |
| U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message |
| U042481 | HVAC Control Module to Hybrid Powertrain Control Module Invalid Serial Data Received |
| U110787 | Lost Communication with Power Management Module Missing Message |
| U117087 | Lost Communication with Brake System Control Module (Secondary CAN Line) Missing Message |
| U117587 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" (Powertrain Bus) Missing Message |
HYBRID CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION [05/2019 - 07/2020]
| DTC Code | Description |
|---|---|
| P056014 | System Voltage (BATT) Circuit Short to Ground or Open |
| P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure |
| P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message |
| P060694 | Hybrid/EV Powertrain Control Module Processor Unexpected Operation |
| P060A29 | Hybrid/EV Powertrain Control Module Monitoring Processor Signal Invalid |
| P060A44 | Hybrid/EV Powertrain Control Module Monitoring Processor Data Memory Failure |
| P060A45 | Hybrid/EV Powertrain Control Module Monitoring Processor Program Memory Failure |
| P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure |
| P060A49 | Hybrid/EV Powertrain Control Module Monitoring Processor Internal Electronic Failure |
| P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message |
| P060A94 | Hybrid/EV Powertrain Control Module Monitoring Processor Unexpected Operation |
| P060B1C | Hybrid/EV Powertrain Control Module A/D Processing Voltage Out of Range |
| P060B49 | Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure |
| P060B71 | Hybrid/EV Powertrain Control Module A/D Processing Actuator Stuck |
| P062F44 | Hybrid/EV Powertrain Control Module EEPROM Data Memory Failure |
| P06881F | ECM/PCM Power Relay Sense Circuit Intermittent |
| P085011 | Park/Neutral Switch Circuit Short to Ground |
| P085015 | Park/Neutral Switch Circuit Short to Auxiliary Battery or Open |
| P08A662 | Gear Lever Position Sensor Signal Compare Failure |
| P0A0A13 | High Voltage System Interlock Circuit Open |
| P0A0A92 | High Voltage System Interlock Performance or Incorrect Operation |
| P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure |
| P0A1B94 | Drive Motor "A" Control Module Unexpected Operation |
| P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
| P0A2A11 | Drive Motor "A" Temperature Sensor Circuit Short to Ground |
| P0A2A15 | Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P0A2A1C | Drive Motor "A" Temperature Sensor Voltage Out of Range |
| P0A2A1F | Drive Motor "A" Temperature Sensor Circuit Intermittent |
| P0A3611 | Generator Temperature Sensor Circuit Short to Ground |
| P0A3615 | Generator Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P0A361C | Generator Temperature Sensor Voltage Out of Range |
| P0A361F | Generator Temperature Sensor Circuit Intermittent |
| P0A9300 | Inverter "A" Cooling System Performance |
| P0AA000 | Hybrid/EV Battery Positive Contactor Circuit Stuck Closed |
| P0AA073 | Hybrid/EV Battery Positive and Negative Contactor Actuator Stuck Closed |
| P0AA373 | Hybrid/EV Battery Negative Contactor Actuator Stuck Closed |
| P0AA649 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure |
| P0AA749 | Hybrid/EV Battery Voltage Isolation Sensor Circuit Internal Electronic Failure |
| P0ABF00 | Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance |
| P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
| P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open |
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground |
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open |
| P0AE173 | Hybrid/EV Battery Precharge Contactor Actuator Stuck Closed |
| P0AE411 | Hybrid/EV Battery Precharge Contactor Circuit Short to Ground |
| P0AE415 | Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open |
| P0B231C | Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range |
| P0C7396 | Motor Electronics Coolant Pump "A" Component Internal Failure |
| P0C7600 | Hybrid/EV Battery System Discharge Time Too Long |
| P0D0700 | Hybrid/EV Battery Charging System Positive Contactor Stuck Closed |
| P0D0773 | Hybrid/EV Battery Charging System Positive/Negative Contactor Actuator Stuck Closed |
| P0D0E73 | Hybrid/EV Battery Charging System Negative Contactor Control Actuator Stuck Closed |
| P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range |
| P0D4C1C | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Voltage Out of Range |
| P0D5C00 | Hybrid/EV Battery Charger Hybrid/EV Battery Output Power Performance |
| P0D5E00 | Hybrid/EV Battery Charger Hybrid/EV System Discharge Time Too Long |
| P0E311C | Boosting Converter Voltage Sensor "A" Voltage Out of Range |
| P0E619E | Hybrid/EV Battery Charger Enable Circuit Stuck On |
| P0E6A73 | Hybrid/EV Battery Charging System Precharge Contactor Control Actuator Stuck Closed |
| P160600 | Collision detected or Collision Sensor Connection (Open) |
| P160604 | Collision detected or Collision Sensor Connection (Open) System Internal Failure |
| P183411 | Gear Lever Y Position Sensor 1 Circuit Short to Ground |
| P183415 | Gear Lever Y Position Sensor 1 Circuit Short to Auxiliary Battery or Open |
| P183A11 | Gear Lever Y Position Sensor 2 Circuit Short to Ground |
| P183A15 | Gear Lever Y Position Sensor 2 Circuit Short to Auxiliary Battery or Open |
| P183F12 | Gear Lever X Position Sensor 1 Circuit Short to Auxiliary Battery |
| P183F14 | Gear Lever X Position Sensor 1 Circuit Short to Ground or Open |
| P184512 | Gear Lever X Position Sensor 2 Circuit Short to Auxiliary Battery |
| P184514 | Gear Lever X Position Sensor 2 Circuit Short to Ground or Open |
| P1AC413 | Hybrid/EV Battery Stack 1 Current Interrupt Device Circuit Open |
| P1C2979 | One Way Clutch Mechanical Linkage Failure |
| P1C2D62 | Hybrid/EV Battery "A" Voltage Sensor/Boosting Converter Voltage Sensor "A" Signal Compare Failure |
| P1C6A9F | Motor Shutdown Stuck Off |
| P1C6C9F | Generator Shutdown Stuck Off |
| P1C7779 | Engine Failed to Start Mechanical Linkage Failure |
| P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
| P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure |
| P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure |
| P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
| P1C8149 | High Voltage Power Resource Circuit Consumption Circuit Short |
| P1C8249 | High Voltage Power Resource Circuit Over Loading |
| P1C8349 | High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction |
| P1C8449 | High Voltage Power Resource Circuit Short during Ready ON |
| P1C8679 | Transmission (Input) Mechanical Linkage Failure |
| P1C8779 | Generator Mechanical Linkage Failure |
| P1C8879 | Planetary Gear Mechanical Linkage Failure |
| P1C9E9F | Hybrid/EV System Reset Stuck Off |
| P1CD800 | Hybrid/EV Powertrain Control Module Processor or Monitoring Processor Charging Permission Signal Internal Failure |
| P1CD900 | Hybrid/EV Powertrain Control Module Processor and Monitoring Processor Charging Permission Signal Stuck On |
| P1CDA00 | Hybrid/EV Powertrain Control Module Processor and Monitoring Processor Charging Permission Signal Stuck Off |
| P1CE213 | PCU Interlock Circuit Open |
| P1CE292 | PCU Interlock Performance or Incorrect Operation |
| P1CE31C | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Voltage Out of Range |
| P1CE349 | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Internal Electronic Failure |
| P1CE371 | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Actuator Stuck |
| P1CF749 | Hybrid/EV Battery Voltage System Isolation (Charger Area) Internal Electronic Failure |
| P1CFA12 | IGB Signal Circuit Short to Auxiliary Battery |
| P212012 | Throttle/Pedal Position Sensor/Switch "D" Circuit Short to Auxiliary Battery |
| P212014 | Throttle/Pedal Position Sensor/Switch "D" Circuit Short to Ground or Open |
| P21201C | Throttle/Pedal Position Sensor/Switch "D" Voltage Out of Range |
| P21201F | Throttle/Pedal Position Sensor/Switch "D" Circuit Intermittent |
| P212512 | Throttle/Pedal Position Sensor/Switch "E" Circuit Short to Auxiliary Battery |
| P212514 | Throttle/Pedal Position Sensor/Switch "E" Circuit Short to Ground or Open |
| P21251C | Throttle/Pedal Position Sensor/Switch "E" Voltage Out of Range |
| P21251F | Throttle/Pedal Position Sensor/Switch "E" Circuit Intermittent |
| P213800 | Throttle/Pedal Position Sensor/Switch "D"/" E" Voltage Correlation |
| P21382B | Throttle/Pedal Position Sensor/Switch "D"/"E" Signal Cross Coupled |
| P253012 | IG2 Signal Circuit Short to Auxiliary Battery |
| P260031 | Motor/Generator Coolant Pump "A" Control Circuit No Signal |
| P260096 | Motor/Generator Coolant Pump "A" Control Circuit Component Internal Failure |
| P26009E | Motor/Generator Coolant Pump "A" Control Circuit Stuck On |
| P272C81 | Park Pawl Motor Invalid Serial Data Received |
| P274A11 | Transmission Fluid Temperature Sensor "C" Circuit Short to Ground |
| P274A15 | Transmission Fluid Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open |
| P274A1C | Transmission Fluid Temperature Sensor "C" Voltage Out of Range |
| P274A1F | Transmission Fluid Temperature Sensor "C" Circuit Intermittent |
| P300449 | High Voltage Power Resource Circuit Short during Pre-Charge |
| P308F49 | High Voltage Charging Circuit Short during Pre-Charge |
| P309F49 | High Voltage Charging Circuit Consumption Circuit Short |
| P310711 | Lost Communication with Airbag System Control Module Circuit Short to Ground |
| P310715 | Lost Communication with Airbag System Control Module Circuit Short to Auxiliary Battery or Open |
| P310764 | Lost Communication with Airbag System Control Module Signal Plausibility Failure |
| P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message |
| P314779 | Transmission (Shaft) Mechanical Linkage Failure |
| P314A31 | Motor Electronics Coolant Pump "A" No Signal |
| P31B300 | Hybrid/EV Battery Voltage High |
| P320F00 | AC Charging Overpower |
| P321D17 | Charger Circuit Voltage Above Threshold |
| P321E9F | Motor/Generator Shutdown Signal Stuck Off |
| P33B99F | Motor/Generator Shutdown Signal (Hybrid/EV Side) Stuck Off |
| P33BF9F | Motor/Generator Shutdown Signal (MG Side) Stuck Off |
| P33CF49 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure Abnormal Area Detection Failure |
| U010087 | Lost Communication with ECM/PCM "A" Missing Message |
| U010487 | Lost Communication with Cruise Control Module Missing Message |
| U011087 | Lost Communication with Drive Motor Control Module "A" Missing Message |
| U011187 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message |
| U012287 | Lost Communication with Vehicle Dynamics Control Module Missing Message |
| U012987 | Lost Communication with Brake System Control Module Missing Message |
| U014000 | Lost Communication with Body Control Module (Sub) Missing Message |
| U014087 | Lost Communication with Body Control Module Missing Message |
| U015187 | Lost Communication with Restraints Control Module Missing Message |
| U016487 | Lost Communication with HVAC Control Module Missing Message |
| U019B87 | Lost Communication with Hybrid/EV Battery Charger Control Module Missing Message |
| U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message |
| U042481 | HVAC Control Module to Hybrid Powertrain Control Module Invalid Serial Data Received |
| U110787 | Lost Communication with Power Management Module Missing Message |
| U117087 | Lost Communication with Brake System Control Module (Secondary CAN Line) Missing Message |
| U117587 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" (Powertrain Bus) Missing Message |
HYBRID CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION [07/2020 - 06/2021]
| DTC Code | Description |
|---|---|
| P056014 | System Voltage (BATT) Circuit Short to Ground or Open |
| P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure |
| P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message |
| P060694 | Hybrid/EV Powertrain Control Module Processor Unexpected Operation |
| P060A29 | Hybrid/EV Powertrain Control Module Monitoring Processor Signal Invalid |
| P060A44 | Hybrid/EV Powertrain Control Module Monitoring Processor Data Memory Failure |
| P060A45 | Hybrid/EV Powertrain Control Module Monitoring Processor Program Memory Failure |
| P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure |
| P060A49 | Hybrid/EV Powertrain Control Module Monitoring Processor Internal Electronic Failure |
| P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message |
| P060A94 | Hybrid/EV Powertrain Control Module Monitoring Processor Unexpected Operation |
| P060B1C | Hybrid/EV Powertrain Control Module A/D Processing Voltage Out of Range |
| P060B49 | Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure |
| P060B71 | Hybrid/EV Powertrain Control Module A/D Processing Actuator Stuck |
| P062F44 | Hybrid/EV Powertrain Control Module EEPROM Data Memory Failure |
| P06881F | ECM/PCM Power Relay Sense Circuit Intermittent |
| P085011 | Park/Neutral Switch Circuit Short to Ground |
| P085015 | Park/Neutral Switch Circuit Short to Auxiliary Battery or Open |
| P08A662 | Gear Lever Position Sensor Signal Compare Failure |
| P0A0A13 | High Voltage System Interlock Circuit Open |
| P0A0A92 | High Voltage System Interlock Performance or Incorrect Operation |
| P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure |
| P0A1B94 | Drive Motor "A" Control Module Unexpected Operation |
| P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
| P0A2A11 | Drive Motor "A" Temperature Sensor Circuit Short to Ground |
| P0A2A15 | Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P0A2A1C | Drive Motor "A" Temperature Sensor Voltage Out of Range |
| P0A2A1F | Drive Motor "A" Temperature Sensor Circuit Intermittent |
| P0A3611 | Generator Temperature Sensor Circuit Short to Ground |
| P0A3615 | Generator Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P0A361C | Generator Temperature Sensor Voltage Out of Range |
| P0A361F | Generator Temperature Sensor Circuit Intermittent |
| P0A9300 | Inverter "A" Cooling System Performance |
| P0AA000 | Hybrid/EV Battery Positive Contactor Circuit Stuck Closed |
| P0AA073 | Hybrid/EV Battery Positive and Negative Contactor Actuator Stuck Closed |
| P0AA373 | Hybrid/EV Battery Negative Contactor Actuator Stuck Closed |
| P0AA649 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure |
| P0AA749 | Hybrid/EV Battery Voltage Isolation Sensor Circuit Internal Electronic Failure |
| P0ABF00 | Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance |
| P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
| P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open |
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground |
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open |
| P0AE173 | Hybrid/EV Battery Precharge Contactor Actuator Stuck Closed |
| P0AE411 | Hybrid/EV Battery Precharge Contactor Circuit Short to Ground |
| P0AE415 | Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open |
| P0B231C | Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range |
| P0C7396 | Motor Electronics Coolant Pump "A" Component Internal Failure |
| P0C7600 | Hybrid/EV Battery System Discharge Time Too Long |
| P0D0700 | Hybrid/EV Battery Charging System Positive Contactor Stuck Closed |
| P0D0773 | Hybrid/EV Battery Charging System Positive/Negative Contactor Actuator Stuck Closed |
| P0D0E73 | Hybrid/EV Battery Charging System Negative Contactor Control Actuator Stuck Closed |
| P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range |
| P0D4C1C | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Voltage Out of Range |
| P0D5C00 | Hybrid/EV Battery Charger Hybrid/EV Battery Output Power Performance |
| P0D5E00 | Hybrid/EV Battery Charger Hybrid/EV System Discharge Time Too Long |
| P0E311C | Boosting Converter Voltage Sensor "A" Voltage Out of Range |
| P0E619E | Hybrid/EV Battery Charger Enable Circuit Stuck On |
| P0E6A73 | Hybrid/EV Battery Charging System Precharge Contactor Control Actuator Stuck Closed |
| P160600 | Collision detected or Collision Sensor Connection (Open) |
| P160604 | Collision detected or Collision Sensor Connection (Open) System Internal Failure |
| P183411 | Gear Lever Y Position Sensor 1 Circuit Short to Ground |
| P183415 | Gear Lever Y Position Sensor 1 Circuit Short to Auxiliary Battery or Open |
| P183A11 | Gear Lever Y Position Sensor 2 Circuit Short to Ground |
| P183A15 | Gear Lever Y Position Sensor 2 Circuit Short to Auxiliary Battery or Open |
| P183F12 | Gear Lever X Position Sensor 1 Circuit Short to Auxiliary Battery |
| P183F14 | Gear Lever X Position Sensor 1 Circuit Short to Ground or Open |
| P184512 | Gear Lever X Position Sensor 2 Circuit Short to Auxiliary Battery |
| P184514 | Gear Lever X Position Sensor 2 Circuit Short to Ground or Open |
| P1AC413 | Hybrid/EV Battery Stack 1 Current Interrupt Device Circuit Open |
| P1C2979 | One Way Clutch Mechanical Linkage Failure |
| P1C2D62 | Hybrid/EV Battery "A" Voltage Sensor/Boosting Converter Voltage Sensor "A" Signal Compare Failure |
| P1C6A9F | Motor Shutdown Stuck Off |
| P1C6C9F | Generator Shutdown Stuck Off |
| P1C7779 | Engine Failed to Start Mechanical Linkage Failure |
| P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
| P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure |
| P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure |
| P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
| P1C8149 | High Voltage Power Resource Circuit Consumption Circuit Short |
| P1C8249 | High Voltage Power Resource Circuit Over Loading |
| P1C8349 | High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction |
| P1C8449 | High Voltage Power Resource Circuit Short during Ready ON |
| P1C8679 | Transmission (Input) Mechanical Linkage Failure |
| P1C8779 | Generator Mechanical Linkage Failure |
| P1C8879 | Planetary Gear Mechanical Linkage Failure |
| P1C9E9F | Hybrid/EV System Reset Stuck Off |
| P1CD800 | Hybrid/EV Powertrain Control Module Processor or Monitoring Processor Charging Permission Signal Internal Failure |
| P1CD900 | Hybrid/EV Powertrain Control Module Processor and Monitoring Processor Charging Permission Signal Stuck On |
| P1CDA00 | Hybrid/EV Powertrain Control Module Processor and Monitoring Processor Charging Permission Signal Stuck Off |
| P1CE213 | PCU Interlock Circuit Open |
| P1CE292 | PCU Interlock Performance or Incorrect Operation |
| P1CE31C | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Voltage Out of Range |
| P1CE349 | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Internal Electronic Failure |
| P1CE371 | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Actuator Stuck |
| P1CF749 | Hybrid/EV Battery Voltage System Isolation (Charger Area) Internal Electronic Failure |
| P1CFA12 | IGB Signal Circuit Short to Auxiliary Battery |
| P212012 | Throttle/Pedal Position Sensor/Switch "D" Circuit Short to Auxiliary Battery |
| P212014 | Throttle/Pedal Position Sensor/Switch "D" Circuit Short to Ground or Open |
| P21201C | Throttle/Pedal Position Sensor/Switch "D" Voltage Out of Range |
| P21201F | Throttle/Pedal Position Sensor/Switch "D" Circuit Intermittent |
| P212512 | Throttle/Pedal Position Sensor/Switch "E" Circuit Short to Auxiliary Battery |
| P212514 | Throttle/Pedal Position Sensor/Switch "E" Circuit Short to Ground or Open |
| P21251C | Throttle/Pedal Position Sensor/Switch "E" Voltage Out of Range |
| P21251F | Throttle/Pedal Position Sensor/Switch "E" Circuit Intermittent |
| P213800 | Throttle/Pedal Position Sensor/Switch "D"/" E" Voltage Correlation |
| P21382B | Throttle/Pedal Position Sensor/Switch "D"/"E" Signal Cross Coupled |
| P253012 | IG2 Signal Circuit Short to Auxiliary Battery |
| P260031 | Motor/Generator Coolant Pump "A" Control Circuit No Signal |
| P260096 | Motor/Generator Coolant Pump "A" Control Circuit Component Internal Failure |
| P26009E | Motor/Generator Coolant Pump "A" Control Circuit Stuck On |
| P272C81 | Park Pawl Motor Invalid Serial Data Received |
| P274A11 | Transmission Fluid Temperature Sensor "C" Circuit Short to Ground |
| P274A15 | Transmission Fluid Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open |
| P274A1C | Transmission Fluid Temperature Sensor "C" Voltage Out of Range |
| P274A1F | Transmission Fluid Temperature Sensor "C" Circuit Intermittent |
| P300449 | High Voltage Power Resource Circuit Short during Pre-Charge |
| P308F49 | High Voltage Charging Circuit Short during Pre-Charge |
| P309F49 | High Voltage Charging Circuit Consumption Circuit Short |
| P310711 | Lost Communication with Airbag System Control Module Circuit Short to Ground |
| P310715 | Lost Communication with Airbag System Control Module Circuit Short to Auxiliary Battery or Open |
| P310764 | Lost Communication with Airbag System Control Module Signal Plausibility Failure |
| P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message |
| P314779 | Transmission (Shaft) Mechanical Linkage Failure |
| P314A31 | Motor Electronics Coolant Pump "A" No Signal |
| P31B300 | Hybrid/EV Battery Voltage High |
| P320F00 | AC Charging Overpower |
| P321D17 | Charger Circuit Voltage Above Threshold |
| P321E9F | Motor/Generator Shutdown Signal Stuck Off |
| P33B99F | Motor/Generator Shutdown Signal (Hybrid/EV Side) Stuck Off |
| P33BF9F | Motor/Generator Shutdown Signal (MG Side) Stuck Off |
| P33CF49 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure Abnormal Area Detection Failure |
| U010087 | Lost Communication with ECM/PCM "A" Missing Message |
| U010487 | Lost Communication with Cruise Control Module Missing Message |
| U011087 | Lost Communication with Drive Motor Control Module "A" Missing Message |
| U011187 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message |
| U012287 | Lost Communication with Vehicle Dynamics Control Module Missing Message |
| U012987 | Lost Communication with Brake System Control Module Missing Message |
| U014000 | Lost Communication with Body Control Module (Sub) Missing Message |
| U014087 | Lost Communication with Body Control Module Missing Message |
| U015187 | Lost Communication with Restraints Control Module Missing Message |
| U016487 | Lost Communication with HVAC Control Module Missing Message |
| U019B87 | Lost Communication with Hybrid/EV Battery Charger Control Module Missing Message |
| U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message |
| U042481 | HVAC Control Module to Hybrid Powertrain Control Module Invalid Serial Data Received |
| U110787 | Lost Communication with Power Management Module Missing Message |
| U117087 | Lost Communication with Brake System Control Module (Secondary CAN Line) Missing Message |
| U117587 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" (Powertrain Bus) Missing Message |
HYBRID CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION [06/2021 - ]
| DTC Code | Description |
|---|---|
| P056014 | System Voltage (BATT) Circuit Short to Ground or Open |
| P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure |
| P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message |
| P060694 | Hybrid/EV Powertrain Control Module Processor Unexpected Operation |
| P060A29 | Hybrid/EV Powertrain Control Module Monitoring Processor Signal Invalid |
| P060A44 | Hybrid/EV Powertrain Control Module Monitoring Processor Data Memory Failure |
| P060A45 | Hybrid/EV Powertrain Control Module Monitoring Processor Program Memory Failure |
| P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure |
| P060A49 | Hybrid/EV Powertrain Control Module Monitoring Processor Internal Electronic Failure |
| P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message |
| P060A94 | Hybrid/EV Powertrain Control Module Monitoring Processor Unexpected Operation |
| P060B1C | Hybrid/EV Powertrain Control Module A/D Processing Voltage Out of Range |
| P060B49 | Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure |
| P060B71 | Hybrid/EV Powertrain Control Module A/D Processing Actuator Stuck |
| P062F44 | Hybrid/EV Powertrain Control Module EEPROM Data Memory Failure |
| P06881F | ECM/PCM Power Relay Sense Circuit Intermittent |
| P085011 | Park/Neutral Switch Circuit Short to Ground |
| P085015 | Park/Neutral Switch Circuit Short to Auxiliary Battery or Open |
| P08A662 | Gear Lever Position Sensor Signal Compare Failure |
| P0A0A13 | High Voltage System Interlock Circuit Open |
| P0A0A92 | High Voltage System Interlock Performance or Incorrect Operation |
| P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure |
| P0A1B94 | Drive Motor "A" Control Module Unexpected Operation |
| P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
| P0A2A11 | Drive Motor "A" Temperature Sensor Circuit Short to Ground |
| P0A2A15 | Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P0A2A1C | Drive Motor "A" Temperature Sensor Voltage Out of Range |
| P0A2A1F | Drive Motor "A" Temperature Sensor Circuit Intermittent |
| P0A3611 | Generator Temperature Sensor Circuit Short to Ground |
| P0A3615 | Generator Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P0A361C | Generator Temperature Sensor Voltage Out of Range |
| P0A361F | Generator Temperature Sensor Circuit Intermittent |
| P0A9300 | Inverter "A" Cooling System Performance |
| P0AA000 | Hybrid/EV Battery Positive Contactor Circuit Stuck Closed |
| P0AA073 | Hybrid/EV Battery Positive and Negative Contactor Actuator Stuck Closed |
| P0AA373 | Hybrid/EV Battery Negative Contactor Actuator Stuck Closed |
| P0AA649 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure |
| P0AA749 | Hybrid/EV Battery Voltage Isolation Sensor Circuit Internal Electronic Failure |
| P0ABF00 | Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance |
| P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
| P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open |
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground |
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open |
| P0AE173 | Hybrid/EV Battery Precharge Contactor Actuator Stuck Closed |
| P0AE411 | Hybrid/EV Battery Precharge Contactor Circuit Short to Ground |
| P0AE415 | Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open |
| P0B231C | Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range |
| P0C7396 | Motor Electronics Coolant Pump "A" Component Internal Failure |
| P0C7600 | Hybrid/EV Battery System Discharge Time Too Long |
| P0D0700 | Hybrid/EV Battery Charging System Positive Contactor Stuck Closed |
| P0D0773 | Hybrid/EV Battery Charging System Positive/Negative Contactor Actuator Stuck Closed |
| P0D0E73 | Hybrid/EV Battery Charging System Negative Contactor Control Actuator Stuck Closed |
| P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range |
| P0D4C1C | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Voltage Out of Range |
| P0D5C00 | Hybrid/EV Battery Charger Hybrid/EV Battery Output Power Performance |
| P0D5E00 | Hybrid/EV Battery Charger Hybrid/EV System Discharge Time Too Long |
| P0E311C | Boosting Converter Voltage Sensor "A" Voltage Out of Range |
| P0E619E | Hybrid/EV Battery Charger Enable Circuit Stuck On |
| P0E6A73 | Hybrid/EV Battery Charging System Precharge Contactor Control Actuator Stuck Closed |
| P160600 | Collision detected or Collision Sensor Connection (Open) |
| P160604 | Collision detected or Collision Sensor Connection (Open) System Internal Failure |
| P183411 | Gear Lever Y Position Sensor 1 Circuit Short to Ground |
| P183415 | Gear Lever Y Position Sensor 1 Circuit Short to Auxiliary Battery or Open |
| P183A11 | Gear Lever Y Position Sensor 2 Circuit Short to Ground |
| P183A15 | Gear Lever Y Position Sensor 2 Circuit Short to Auxiliary Battery or Open |
| P183F12 | Gear Lever X Position Sensor 1 Circuit Short to Auxiliary Battery |
| P183F14 | Gear Lever X Position Sensor 1 Circuit Short to Ground or Open |
| P184512 | Gear Lever X Position Sensor 2 Circuit Short to Auxiliary Battery |
| P184514 | Gear Lever X Position Sensor 2 Circuit Short to Ground or Open |
| P1AC413 | Hybrid/EV Battery Stack 1 Current Interrupt Device Circuit Open |
| P1C2979 | One Way Clutch Mechanical Linkage Failure |
| P1C2D62 | Hybrid/EV Battery "A" Voltage Sensor/Boosting Converter Voltage Sensor "A" Signal Compare Failure |
| P1C6A9F | Motor Shutdown Stuck Off |
| P1C6C9F | Generator Shutdown Stuck Off |
| P1C7779 | Engine Failed to Start Mechanical Linkage Failure |
| P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
| P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure |
| P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure |
| P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
| P1C8149 | High Voltage Power Resource Circuit Consumption Circuit Short |
| P1C8249 | High Voltage Power Resource Circuit Over Loading |
| P1C8349 | High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction |
| P1C8449 | High Voltage Power Resource Circuit Short during Ready ON |
| P1C8679 | Transmission (Input) Mechanical Linkage Failure |
| P1C8779 | Generator Mechanical Linkage Failure |
| P1C8879 | Planetary Gear Mechanical Linkage Failure |
| P1C9E9F | Hybrid/EV System Reset Stuck Off |
| P1CD800 | Hybrid/EV Powertrain Control Module Processor or Monitoring Processor Charging Permission Signal Internal Failure |
| P1CD900 | Hybrid/EV Powertrain Control Module Processor and Monitoring Processor Charging Permission Signal Stuck On |
| P1CDA00 | Hybrid/EV Powertrain Control Module Processor and Monitoring Processor Charging Permission Signal Stuck Off |
| P1CE213 | PCU Interlock Circuit Open |
| P1CE292 | PCU Interlock Performance or Incorrect Operation |
| P1CE31C | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Voltage Out of Range |
| P1CE349 | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Internal Electronic Failure |
| P1CE371 | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Actuator Stuck |
| P1CF749 | Hybrid/EV Battery Voltage System Isolation (Charger Area) Internal Electronic Failure |
| P1CFA12 | IGB Signal Circuit Short to Auxiliary Battery |
| P212012 | Throttle/Pedal Position Sensor/Switch "D" Circuit Short to Auxiliary Battery |
| P212014 | Throttle/Pedal Position Sensor/Switch "D" Circuit Short to Ground or Open |
| P21201C | Throttle/Pedal Position Sensor/Switch "D" Voltage Out of Range |
| P21201F | Throttle/Pedal Position Sensor/Switch "D" Circuit Intermittent |
| P212512 | Throttle/Pedal Position Sensor/Switch "E" Circuit Short to Auxiliary Battery |
| P212514 | Throttle/Pedal Position Sensor/Switch "E" Circuit Short to Ground or Open |
| P21251C | Throttle/Pedal Position Sensor/Switch "E" Voltage Out of Range |
| P21251F | Throttle/Pedal Position Sensor/Switch "E" Circuit Intermittent |
| P213800 | Throttle/Pedal Position Sensor/Switch "D"/" E" Voltage Correlation |
| P21382B | Throttle/Pedal Position Sensor/Switch "D"/"E" Signal Cross Coupled |
| P253012 | IG2 Signal Circuit Short to Auxiliary Battery |
| P260031 | Motor/Generator Coolant Pump "A" Control Circuit No Signal |
| P260096 | Motor/Generator Coolant Pump "A" Control Circuit Component Internal Failure |
| P26009E | Motor/Generator Coolant Pump "A" Control Circuit Stuck On |
| P272C81 | Park Pawl Motor Invalid Serial Data Received |
| P274A11 | Transmission Fluid Temperature Sensor "C" Circuit Short to Ground |
| P274A15 | Transmission Fluid Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open |
| P274A1C | Transmission Fluid Temperature Sensor "C" Voltage Out of Range |
| P274A1F | Transmission Fluid Temperature Sensor "C" Circuit Intermittent |
| P300449 | High Voltage Power Resource Circuit Short during Pre-Charge |
| P308F49 | High Voltage Charging Circuit Short during Pre-Charge |
| P309F49 | High Voltage Charging Circuit Consumption Circuit Short |
| P310711 | Lost Communication with Airbag System Control Module Circuit Short to Ground |
| P310715 | Lost Communication with Airbag System Control Module Circuit Short to Auxiliary Battery or Open |
| P310764 | Lost Communication with Airbag System Control Module Signal Plausibility Failure |
| P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message |
| P314779 | Transmission (Shaft) Mechanical Linkage Failure |
| P314A31 | Motor Electronics Coolant Pump "A" No Signal |
| P31B300 | Hybrid/EV Battery Voltage High |
| P320F00 | AC Charging Overpower |
| P321D17 | Charger Circuit Voltage Above Threshold |
| P321E9F | Motor/Generator Shutdown Signal Stuck Off |
| P33B99F | Motor/Generator Shutdown Signal (Hybrid/EV Side) Stuck Off |
| P33BF9F | Motor/Generator Shutdown Signal (MG Side) Stuck Off |
| P33CF49 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure Abnormal Area Detection Failure |
| U010087 | Lost Communication with ECM/PCM "A" Missing Message |
| U010487 | Lost Communication with Cruise Control Module Missing Message |
| U011087 | Lost Communication with Drive Motor Control Module "A" Missing Message |
| U011187 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message |
| U012287 | Lost Communication with Vehicle Dynamics Control Module Missing Message |
| U012987 | Lost Communication with Brake System Control Module Missing Message |
| U014000 | Lost Communication with Body Control Module (Sub) Missing Message |
| U014087 | Lost Communication with Body Control Module Missing Message |
| U015187 | Lost Communication with Restraints Control Module Missing Message |
| U016487 | Lost Communication with HVAC Control Module Missing Message |
| U019B87 | Lost Communication with Hybrid/EV Battery Charger Control Module Missing Message |
| U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message |
| U042481 | HVAC Control Module to Hybrid Powertrain Control Module Invalid Serial Data Received |
| U110787 | Lost Communication with Power Management Module Missing Message |
| U117087 | Lost Communication with Brake System Control Module (Secondary CAN Line) Missing Message |
| U117587 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" (Powertrain Bus) Missing Message |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.