2015 Toyota Prius Plug-inFACTORY OEM SERVICE PROCEDURE

DTC P2511-441: Reset Detected [08/2014 - ]: Procedure

  1. CHECK DTC OUTPUT (PLUG-IN CONTROL) 
    1. Connect the Techstream to the DLC3.
    2. Turn the power switch on (IG).
    3. Enter the following menus: Powertrain / Plug-in Control / Trouble Codes.
    4. Check if DTCs are output.

      Result

      Result Proceed to
      P2511-441 only is output. A
      DTCs other than P2511-441 is output. B
    5. Turn the power switch off.

    B → See step   5 

    A: Go to next step 

  2. CHECK AUXILIARY BATTERY TERMINAL (CONTACT PROBLEM) 
    1. Check the connection of the auxiliary battery terminal.

      OK

      The terminal is connected securely and there is no contact problem.

    NG → CONNECT SECURELY 

    OK: Go to next step 

  3. CHECK FOR ECU POWER SOURCE CIRCUIT 

    Refer to ECU Power Source Circuit [08/2014 - ] 

    NG → REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA 

    OK: Go to next step 

  4. CHECK FOR INTERMITTENT PROBLEMS 
    1. Check for intermittent problems. Refer to CHECK FOR INTERMITTENT PROBLEMS [08/2014 - ] .

      Result

      Result Proceed to
      Problem symptom does not recur. A
      Problem symptom recurs. B

    B → REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA 

    A → See step   6 

  5. GO TO DTC CHART (PLUG-IN CHARGE CONTROL SYSTEM). Refer to  DIAGNOSTIC TROUBLE CODE CHART [08/2014 - ] 
  6. REPLACE PLUGIN CHARGE CONTROL ECU ASSEMBLY. Refer to  COMPONENTS [08/2014 - ] 
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.