2013 Toyota Sienna SEFACTORY OEM SERVICE PROCEDURE

On-Vehicle Inspection

  1. INSPECT EFI MAIN RELAY 
    1. Measure the resistance according to the value(s) in the table below.
      Fig 1: Inspecting Battery Blower Terminal Relays
      GTY298943Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard Resistance

      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage not applied 10 kΩ or higher
      3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the relay.

  2. INSPECT C/OPN RELAY 
    1. Measure the resistance according to the value(s) in the table below.
      Fig 2: Inspecting Battery Blower Terminal Relays
      GTY298943Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard Resistance

      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage not applied 10 kΩ or higher
      3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the relay.

  3. INSPECT F/PMP RELAY 
    1. Measure the resistance according to the value(s) in the table below.
      Fig 3: Identifying F/PMP Relay
      GTY274977Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard Resistance

      Tester Connection Condition Specified Condition
      3 - 4 Battery voltage not applied Below 1 Ω
      3 - 5 Battery voltage not applied 10 kΩ or higher
      3 - 4 Battery voltage applied to terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the relay.

  4. INSPECT IG2 RELAY (w/ Smart Key System) 
    1. Measure the resistance according to the value(s) in the table below.
      Fig 4: Inspecting Battery Blower Terminal Relays
      GTY298943Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard Resistance

      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage not applied 10 kΩ or higher
      3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the relay.

  5. INSPECT AIR FUEL RATIO SENSOR HEATER RELAY 
    1. Measure the resistance according to the value(s) in the table below.
      Fig 5: Inspecting Battery Blower Terminal Relays
      GTY298943Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard Resistance

      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage not applied 10 kΩ or higher
      3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the relay.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.