2013 Toyota Prius ThreeFACTORY OEM SERVICE PROCEDURE

Fail-Safe Chart

WARNING: This page is about a different variant/trim than selected.

If a problem occurs in the power steering system, the power steering assist will be stopped, locked at a particular point, or decreased simultaneously to protect the system.

DTC No. DTC Detection Condition Fail-safe
C1511/11
C1512/12
C1513/13
C1514/14
C1515/15
C1516/16
Torque sensor malfunction Assist force restricted or power assist stopped
C1517/17 Torque sensor malfunction
C1524/24 Motor malfunction
C1531/31
C1532/32
Power steering ECU assembly malfunction
C1533/33 Temperature sensor malfunction in power steering ECU assembly
C1534/34 EEPROM abnormal
C1535/35 Steering wheel location data error
C1551/51 IG power source voltage error Power assist stopped
C1552/52 PIG power source voltage error
C1553/53 Overvoltage at IG and PIG terminals
C1554/54 Power source relay malfunction
C1555/55 Motor relay malfunction
C1581/81 ECU malfunction (Assist map number un-writing) Permission of control assist map
C1582/82 Assist map mismatch written in power steering ECU assembly Controlled using current default map
U0129/93 Lost communication with brake actuator assembly Assist force restricted
U0293/92 HV ECU communication error Power assist stopped

HINT:Β 

  • The amount of power assist may be decreased to prevent the motor and ECUs from overheating if the steering wheel is continuously turned when the vehicle is either stopped or driven at a low speed, or if the steering wheel is kept in either full lock position for a long time. In such cases, the amount of power assist returns to normal if the steering wheel is not turned for approximately 10 minutes with the power switch on (READY).
  • If the auxiliary battery is not sufficiently charged or the voltage decreases temporarily, the amount of power assist will be reduced and the EPS warning light will come on. In such cases, the amount of power assist returns normal when the auxiliary battery voltage recovers.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.