2012 Toyota Prius TwoFACTORY OEM SERVICE PROCEDURE

DTC B2313: Glass Position Initialization Incomplete: Procedure

  1. PERFORM INITIALIZATION (APPLICABLE LOCATION) 
    1. Turn the power switch on (IG).
    2. Initialize the power window regulator motor assembly. Refer to INITIALIZATION .

      HINT: 

      Initialize the power window regulator motor assembly that has DTC B2313 stored in its ECU.

    NEXT: Go to next step 

  2. CHECK DTC OUTPUT 
    1. Turn the power switch off.
    2. Wait for at least 10 seconds, and then turn the power switch on (IG).
    3. Check for DTCs. Refer to DTC CHECK / CLEAR .

      HINT: 

      Check for DTCs for the power window regulator motor assembly that has DTC B2313 stored in its ECU.

      OK

      DTC B2313 is not output.

      Result

      Result Proceed to
      OK A
      NG (Driver door power window) B
      NG (Front passenger side power window) C
      NG (Rear LH side power window) D
      NG (Rear RH side power window) E

    B → See step   3 

    C → See step   4 

    D → See step   5 

    E → See step   6 

    A → END (POWER WINDOW CONTROL SYSTEM HAS NOT BEEN INITIALIZED) 

  3. REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Driver Side). Refer to  REMOVAL 
  4. REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Front Passenger Side). Refer to  REMOVAL 
  5. REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Rear LH Side). Refer to  REMOVAL 
  6. REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Rear RH Side). Refer to  REMOVAL 
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.