2012 Toyota Prius ThreeFACTORY OEM SERVICE PROCEDURE
HV Relay Assembly: Inspection: Inspection
WARNING: This page is about a different variant/trim than selected.
- HYBRID BATTERY JUNCTION BLOCK ASSEMBLY
- Inspect SMRB.
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard Resistance
Tester Connection Condition Specified Condition w2-1 (+) - T15-1 (CBI) Auxiliary battery voltage is not applied between terminals c3-4 (SMRB) and c3-2 (GND) 10 kΩ or higher w2-1 (+) - T15-1 (CBI) Auxiliary battery voltage is applied between terminals c3-4 (SMRB) and c3-2 (GND) Below 1 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Hybrid Battery Junction Block Assembly) - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition c9-1 (SMRB) - c9-2 (GND1) -40 to 80°C (-40 to 176°F) 19.0 to 35.5 Ω
- Measure the resistance according to the value(s) in the table below.
- Inspect SMRG.
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard Resistance
Tester Connection Condition Specified Condition q8-1 (-) - T14-1 (CEI) Auxiliary battery voltage is not applied between terminals c3-1 (SMRG) and c3-2 (GND) 10 kΩ or higher q8-1 (-) - T14-1 (CEI) Auxiliary battery voltage is applied between terminals c3-1 (SMRG) and c3-2 (GND) Below 1 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Hybrid Battery Junction Block Assembly) - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition o10-1 (SMRG) - o10-2 (GND) -40 to 80°C (-40 to 176°F) 19.0 to 35.5 Ω
- Measure the resistance according to the value(s) in the table below.
- Inspect SMRP.
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard Resistance
Tester Connection Condition Specified Condition T14-1 (CEI) - q8-1 (-) Auxiliary battery voltage is not applied between terminals o9-1 (SMRP) and o9-2 (GND2) 10 kΩ or higher T14-1 (CEI) - q8-1 (-) Auxiliary battery voltage is applied between terminals o9-1 (SMRP) and o9-2 (GND2) 28.5 to 31.5 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Hybrid Battery Junction Block Assembly) - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition o9-1 (SMRP) and o9-2 (GND2) -40 to 80 °C (-40 to 176°F) 112 to 274 Ω
- Measure the resistance according to the value(s) in the table below.
- Inspect CHRB.
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard Resistance
Tester Connection Condition Specified Condition T15-1 (CBI) - a3-6 (DCHB) Auxiliary battery voltage is not applied between terminals o9-5 (CHRB) - o9-4 (GND) 10 kΩ or higher T15-1 (CBI) - a3-6 (DCHB) Auxiliary battery voltage is applied between terminals o9-5 (CHRB) - o9-4 (GND) Below 1 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Hybrid Battery Junction Block Assembly) - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition o9-5 (CHRB) - o9-4 (GND) -40 to 80 °C (-40 to 176°F) 112 to 274 Ω
- Measure the resistance according to the value(s) in the table below.
- Inspect CHRG.
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard Resistance
Tester Connection Condition Specified Condition T14-1 (CEI) - a3-6 (DCHG) Auxiliary battery voltage is not applied between terminals o9-3 (CHRG) - o9-4 (GND) 10 kΩ or higher T14-1 (CEI) - a3-6 (DCHG) Auxiliary battery voltage is applied between terminals o9-3 (CHRG) - o9-4 (GND) Below 1 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Hybrid Battery Junction Block Assembly) - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition o9-3 (CHRG) - o9-4 (GND) -40 to 80 °C (-40 to 176°F) 112 to 274 Ω
- Measure the resistance according to the value(s) in the table below.
- Inspect SMRB.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.