DTC U0293-449: Lost Communication with Hybrid Powertrain Control Module: Procedure
- CHECK DTC OUTPUT (HEALTH CHECK)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: System Select / Health Check.
- Check if DTCs are output.
Result
Result Proceed to Only U0293-449 is output. A Only U0293-439 and U0293-449 are also output. B U0293-449 and any CAN communication system DTC other than U0293-439 are output. C - Turn the power switch off.
B → See step 7
C → See step 8
A: Go to next step
- CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - PLUGIN CHARGE CONTROL ECU ASSEMBLY) See step 2
NG → See step 5
OK: Go to next step
- CHECK POWER MANAGEMENT CONTROL ECU (PIBM VOLTAGE)
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition L135-10 (PIBM) - Body ground Power switch off 11 to 14 V TEXT IN ILLUSTRATION*a Component with harness connected
(Power Management Control ECU)
NG → See step 6
OK: Go to next step
- Measure the voltage according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND). Refer to PROCEDURE - Step 2
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 9
- CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - PLUGIN CHARGE CONTROL ECU ASSEMBLY) See step 6
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 10
- CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - PIMR RELAY)
- Disconnect connector L135 from the power management control ECU.
- Remove the PIMR relay from the relay block assembly.
- Measure the resistance according to the value(s) in the table below.TEXT IN ILLUSTRATION
*1 Relay Block Assembly (PIMR Relay) - - *a Rear view of wire harness connector
(to Power Management Control ECU)- - Standard Resistance (Check for Open)
Tester Connection Switch Condition Specified Condition L135-10 (PIBM) - 5 (L) Power switch off Below 1 Ω Standard Resistance (Check for Short)
Tester Connection Switch Condition Specified Condition L135-10 (PIBM) or 5 (L) - Body ground and other terminals Power switch off 10 kΩ or higher - Install the PIMR relay.
- Connect the power management control ECU connector.
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 9
- GO TO DTC CHART (U0293-439). Refer to DTC U0293-439: Lost Communication with Hybrid Powertrain Control Module
- GO TO CAN COMMUNICATION SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING
- REPLACE POWER MANAGEMENT CONTROL ECU. Refer to COMPONENTS
- REPLACE PLUGIN CHARGE CONTROL ECU ASSEMBLY. Refer to COMPONENTS
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.