Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Lighting System: Initialization: Initialization
- HEIGHT CONTROL SENSOR SIGNAL INITIALIZATIONÂ NOTE:
- Initialize the headlight beam level control ECU when vehicle height changes due to replacement of the suspension, headlight beam level control ECU, or removal, installation, or replacement of the height control sensor.
- Adjust the headlight aim after initializing the headlight beam level control ECU. Refer to ADJUSTMENT .
- CHECK VEHICLE CONDITIONÂ
- Leave approximately 10 liters of fuel in the tank.
- Unload the vehicle.
- Check that there are no passengers in the vehicle.
- Turn off the headlights.
NEXT: Go to next stepÂ
- CHECK WARNING INDICATORÂ
- Turn the ignition switch on (IG) and check the warning indicator (bulb check function).
OK
Warning indicator comes on for approximately 3 seconds.
HINT:Â
- If the headlight beam level control ECU is replaced with a new one or there is problem with initialized data memorized in the headlight beam level control ECU, the warning indicator repeats the following pattern: 2 Hz for one second, followed by a 1 second pause.
- If the warning indicator does not come on or comes on for more than 3 seconds, inspect and repair according to "PROBLEM SYMPTOMS TABLE". Refer to PROBLEM SYMPTOMS TABLEÂ .
NEXT: Go to next stepÂ
- Turn the ignition switch on (IG) and check the warning indicator (bulb check function).
- INITIALIZATIONÂ
- Connect terminals 4 (CG) and 8 (LVL) of the DLC3 using the SST.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- SST: 09843-18040Â
- Flash the headlight 3 times within 20 seconds by turning the headlight dimmer switch.NOTE:
Flash the headlight at approximately 1 second intervals.
OK
Condition Proceed to Warning indicator blinks 3 times at 0.5 second intervals → goes off A Warning indicator does not blink or continues blinking B HINT:Â
If initialization cannot finished normally, inspect the initialization circuit. Refer to LVL Terminal Circuit .
B → INITIALIZED TERMINAL CIRCUIT IS FAULTYÂ
A → END (NORMAL COMPLETE)Â
- Connect terminals 4 (CG) and 8 (LVL) of the DLC3 using the SST.
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.