2009 Toyota Highlander Limited, FWDFACTORY OEM SERVICE PROCEDURE

Inspection Procedure

  1. CHECK MIL 
    1. Check that the Malfunction Indicator Lamp (MIL) lights up when turning the ignition switch on (IG).

      OK: 

      MIL lights up. 

      NG: Go to step 2 

      OK:  GO TO MIL CIRCUIT 

  2. CHECK CONNECTION BETWEEN TECHSTREAM AND ECM 
    1. Connect the Techstream to the DLC3.
    2. Turn the ignition switch on (IG) and turn the tester on.
    3. Check the communication between the tester and ECM.

      Result 

      RESULT CHART

      Result Proceed to
      Communication is possible A
      Communication is not possible B

      A:  GO TO MIL CIRCUIT 

      B: Go to next step 

  3. CHECK THROTTLE BODY (CHECK MIL ILLUMINATED) 
    1. Disconnect the throttle body connector.
    2. Turn the ignition switch on (IG).
    3. Check the MIL.

      Result 

      RESULT CHART

      Result Proceed to
      MIL illuminates A
      MIL does not illuminate B
    4. Reconnect the throttle body connector.

      A: REPLACE THROTTLE BODY  (See THROTTLE BODY  )

      B: Go to next step 

  4. CHECK ACCELERATOR PEDAL ROD (CHECK MIL ILLUMINATED) 
    1. Disconnect the accelerator pedal position sensor connector.
    2. Turn the ignition switch on (IG).
    3. Check the MIL.

      Result 

      RESULT CHART

      Result Proceed to
      MIL illuminates A
      MIL does not illuminate B
    4. Reconnect the accelerator pedal position sensor connector.

      A: REPLACE ACCELERATOR PEDAL ROD  (See REMOVAL  )

      B: Go to next step 

  5. CHECK VVT SENSOR FOR INTAKE CAMSHAFT BANK 1 (CHECK MIL ILLUMINATED) 
    1. Disconnect the VVT sensor for intake camshaft bank 1 connector.
    2. Turn the ignition switch on (IG).
    3. Check the MIL.

      Result 

      RESULT CHART

      Result Proceed to
      MIL illuminates A
      MIL does not illuminate B
    4. Reconnect the VVT sensor for intake camshaft bank 1 connector.

      A: REPLACE VVT SENSOR FOR INTAKE CAMSHAFT BANK 1  (See VVT SENSOR  )

      B: Go to next step 

  6. CHECK VVT SENSOR FOR EXHAUST CAMSHAFT BANK 1 (CHECK MIL ILLUMINATED) 
    1. Disconnect the VVT sensor for exhaust camshaft bank 1 connector.
    2. Turn the ignition switch on (IG).
    3. Check the MIL

      Result 

      RESULT CHART

      Result Proceed to
      MIL illuminates A
      MIL does not illuminate B
    4. Reconnect the VVT sensor for exhaust camshaft bank 1 connector.

      A: REPLACE VVT SENSOR FOR EXHAUST CAMSHAFT BANK 1  (See VVT SENSOR  )

      B: Go to next step 

  7. CHECK VVT SENSOR FOR INTAKE CAMSHAFT BANK 2 (CHECK MIL ILLUMINATED) 
    1. Disconnect the VVT sensor for intake camshaft bank 2 connector.
    2. Turn the ignition switch on (IG).
    3. Check the MIL.

      Result 

      RESULT CHART

      Result Proceed to
      MIL illuminates A
      MIL does not illuminate B
    4. Reconnect the VVT sensor for intake camshaft bank 2 connector.

      A: REPLACE VVT SENSOR FOR INTAKE CAMSHAFT BANK 2  (See VVT SENSOR  )

      B: Go to next step 

  8. CHECK VVT SENSOR FOR EXHAUST CAMSHAFT BANK 2 (CHECK MIL ILLUMINATED) 
    1. Disconnect the VVT sensor for exhaust camshaft bank 2 connector.
    2. Turn the ignition switch on (IG).
    3. Check the MIL.

      Result 

      RESULT CHART

      Result Proceed to
      MIL illuminates A
      MIL does not illuminate B
    4. Reconnect the VVT sensor for exhaust camshaft bank 2 connector.

      A: REPLACE VVT SENSOR FOR EXHAUST CAMSHAFT BANK 2  (See VVT SENSOR  )

      B: Go to next step 

  9. CHECK CHARCOAL CANISTER ASSEMBLY (CHECK MIL ILLUMINATED) 
    1. Disconnect the canister pump module connector.
    2. Turn the ignition switch on (IG).
    3. Check the MIL.

      Result 

      RESULT CHART

      Result Proceed to
      MIL illuminates A
      MIL does not illuminate B
    4. Reconnect the canister pump module connector.

      A: REPLACE CHARCOAL CANISTER ASSEMBLY  (See CANISTER )

      B: Go to next step 

  10. CHECK HARNESS AND CONNECTOR 
    1. Disconnect the throttle body connector.
    2. Disconnect the accelerator pedal position sensor connector.
    3. Disconnect the VVT sensor for intake camshaft bank 1 connector.
    4. Disconnect the VVT sensor for exhaust camshaft bank 1 connector.
    5. Disconnect the VVT sensor for intake camshaft bank 2 connector.
    6. Disconnect the VVT sensor for exhaust camshaft bank 2 connector.
    7. Disconnect the canister pump module connector.
    8. Disconnect the ECM connectors.
    9. Measure the resistance according to the value(s) in the table below.
      Fig 1: Identifying ECM Connector Terminals
      G05413905Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard resistance (Check for short) 

      TESTER CONNECTION SPECIFIED CONDITION CHART

      Tester Connections Condition Specified Conditions
      VC (B1-23) - Body ground Always 10 kΩ or higher
      VCPA (D35-26) - Body ground Always 10 kΩ or higher
      VCP2 (D35-27) - Body ground Always 10 kΩ or higher
    10. Reconnect the ECM connectors.
    11. Reconnect the canister pump module connector.
    12. Reconnect the VVT sensor for exhaust camshaft bank 2 connector.
    13. Reconnect the VVT sensor for intake camshaft bank 2 connector.
    14. Reconnect the VVT sensor for exhaust camshaft bank 1 connector.
    15. Reconnect the VVT sensor for intake camshaft bank 1 connector.
    16. Reconnect the accelerator pedal position sensor connector.
    17. Reconnect the throttle body connector.

      NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

      OK: REPLACE ECM  (See REMOVAL  )

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.