Inspection Procedure
- CHECK MILÂ
- Check that the Malfunction Indicator Lamp (MIL) lights up when turning the ignition switch on (IG).
OK:Â
MIL lights up.Â
NG: Go to step 2Â
OK:Â GO TO MIL CIRCUITÂ
- Check that the Malfunction Indicator Lamp (MIL) lights up when turning the ignition switch on (IG).
- CHECK CONNECTION BETWEEN TECHSTREAM AND ECMÂ
- Connect the Techstream to the DLC3.
- Turn the ignition switch on (IG) and turn the tester on.
- Check the communication between the tester and ECM.
ResultÂ
RESULT CHARTResult Proceed to Communication is possible A Communication is not possible B A:Â GO TO MIL CIRCUITÂ
B: Go to next stepÂ
- CHECK THROTTLE BODY (CHECK MIL ILLUMINATED)Â
- Disconnect the throttle body connector.
- Turn the ignition switch on (IG).
- Check the MIL.
ResultÂ
RESULT CHARTResult Proceed to MIL illuminates A MIL does not illuminate B - Reconnect the throttle body connector.
A: REPLACE THROTTLE BODYÂ (See THROTTLE BODYÂ )
B: Go to next stepÂ
- CHECK ACCELERATOR PEDAL ROD (CHECK MIL ILLUMINATED)Â
- Disconnect the accelerator pedal position sensor connector.
- Turn the ignition switch on (IG).
- Check the MIL.
ResultÂ
RESULT CHARTResult Proceed to MIL illuminates A MIL does not illuminate B - Reconnect the accelerator pedal position sensor connector.
A: REPLACE ACCELERATOR PEDAL RODÂ (See REMOVALÂ )
B: Go to next stepÂ
- CHECK VVT SENSOR FOR INTAKE CAMSHAFT BANK 1 (CHECK MIL ILLUMINATED)Â
- Disconnect the VVT sensor for intake camshaft bank 1 connector.
- Turn the ignition switch on (IG).
- Check the MIL.
ResultÂ
RESULT CHARTResult Proceed to MIL illuminates A MIL does not illuminate B - Reconnect the VVT sensor for intake camshaft bank 1 connector.
A: REPLACE VVT SENSOR FOR INTAKE CAMSHAFT BANK 1Â (See VVT SENSORÂ )
B: Go to next stepÂ
- CHECK VVT SENSOR FOR EXHAUST CAMSHAFT BANK 1 (CHECK MIL ILLUMINATED)Â
- Disconnect the VVT sensor for exhaust camshaft bank 1 connector.
- Turn the ignition switch on (IG).
- Check the MIL
ResultÂ
RESULT CHARTResult Proceed to MIL illuminates A MIL does not illuminate B - Reconnect the VVT sensor for exhaust camshaft bank 1 connector.
A: REPLACE VVT SENSOR FOR EXHAUST CAMSHAFT BANK 1Â (See VVT SENSORÂ )
B: Go to next stepÂ
- CHECK VVT SENSOR FOR INTAKE CAMSHAFT BANK 2 (CHECK MIL ILLUMINATED)Â
- Disconnect the VVT sensor for intake camshaft bank 2 connector.
- Turn the ignition switch on (IG).
- Check the MIL.
ResultÂ
RESULT CHARTResult Proceed to MIL illuminates A MIL does not illuminate B - Reconnect the VVT sensor for intake camshaft bank 2 connector.
A: REPLACE VVT SENSOR FOR INTAKE CAMSHAFT BANK 2Â (See VVT SENSORÂ )
B: Go to next stepÂ
- CHECK VVT SENSOR FOR EXHAUST CAMSHAFT BANK 2 (CHECK MIL ILLUMINATED)Â
- Disconnect the VVT sensor for exhaust camshaft bank 2 connector.
- Turn the ignition switch on (IG).
- Check the MIL.
ResultÂ
RESULT CHARTResult Proceed to MIL illuminates A MIL does not illuminate B - Reconnect the VVT sensor for exhaust camshaft bank 2 connector.
A: REPLACE VVT SENSOR FOR EXHAUST CAMSHAFT BANK 2Â (See VVT SENSORÂ )
B: Go to next stepÂ
- CHECK CHARCOAL CANISTER ASSEMBLY (CHECK MIL ILLUMINATED)Â
- Disconnect the canister pump module connector.
- Turn the ignition switch on (IG).
- Check the MIL.
ResultÂ
RESULT CHARTResult Proceed to MIL illuminates A MIL does not illuminate B - Reconnect the canister pump module connector.
A: REPLACE CHARCOAL CANISTER ASSEMBLYÂ (See CANISTER )
B: Go to next stepÂ
- CHECK HARNESS AND CONNECTORÂ
- Disconnect the throttle body connector.
- Disconnect the accelerator pedal position sensor connector.
- Disconnect the VVT sensor for intake camshaft bank 1 connector.
- Disconnect the VVT sensor for exhaust camshaft bank 1 connector.
- Disconnect the VVT sensor for intake camshaft bank 2 connector.
- Disconnect the VVT sensor for exhaust camshaft bank 2 connector.
- Disconnect the canister pump module connector.
- Disconnect the ECM connectors.
- Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for short)Â
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connections Condition Specified Conditions VC (B1-23) - Body ground Always 10 kΩ or higher VCPA (D35-26) - Body ground Always 10 kΩ or higher VCP2 (D35-27) - Body ground Always 10 kΩ or higher - Reconnect the ECM connectors.
- Reconnect the canister pump module connector.
- Reconnect the VVT sensor for exhaust camshaft bank 2 connector.
- Reconnect the VVT sensor for intake camshaft bank 2 connector.
- Reconnect the VVT sensor for exhaust camshaft bank 1 connector.
- Reconnect the VVT sensor for intake camshaft bank 1 connector.
- Reconnect the accelerator pedal position sensor connector.
- Reconnect the throttle body connector.
NG: REPAIR OR REPLACE HARNESS OR CONNECTORÂ
OK: REPLACE ECMÂ (See REMOVALÂ )
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.