2008 Toyota RAV4 Base, 2.4 D, AWDFACTORY OEM SERVICE PROCEDURE

VVT Sensor: Installation

WARNING: This page is about a different variant/trim than selected.
  1. INSTALL VVT SENSOR 
    1. Install the 4 sensors with the 4 bolts.

      Torque: 10 N*m (102 kgf*cm, 7 ft.*lbf) 

      Fig 1: Identifying VVT Sensor And Bolts
      G05184262Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Connect the 4 sensor connectors.
  2. INSTALL INTAKE AIR SURGE TANK ASSEMBLY 
    NOTE: Make sure there is no oil on the bolts. If there is oil on the bolts, clean them before installing them.
    1. Install a new gasket to the surge tank.
    2. Using a 5 mm hexagon socket wrench, install the 4 bolts.

      Torque: 18 N*m (184 kgf*cm, 13 ft.*lbf) 

    3. Install the surge tank with the 2 nuts and 2 bolts.

      Torque: 

      21 N*m (214 kgf*cm, 15 ft.*lbf) for bolt 

      16 N*m (163 kgf*cm, 12 ft.*lbf) for nut 

      Fig 2: Identifying Intake Air Surge Tank Assembly Nuts And Bolts
      G04485101Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    4. Connect the connector.
      Fig 3: Identifying Connector
      G04485102Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    5. Install the vacuum hose clamp with the bolt.

      Torque: 5.4 N*m (55 kgf*cm, 48 in.*lbf) 

      Fig 4: Identifying Vacuum Hose Clamp Bolt
      G04485103Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    6. Connect the union to check valve hose.
    7. Connect the No. 2 ventilation hose.
    8. Fig 5: Identifying Hoses And Clamps
      G04485104Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    9. Install the clamp and connect the throttle body connector.
    10. Connect the vapor feed hose.
    11. Connect the 2 water by-pass hoses to the throttle body.
      Fig 6: Connecting Water By-Pass Hoses To Throttle Body
      G04485105Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL 
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.